← Back
General warehouse
8156 NEW UTRECHT AVENUE
BROOKLYN · Bensonhurst · BIN 3164644
💬 Discuss this project
1987Year Built
1Stories
E1Building Class
M1-1Zoning
5,120 sfGross Floor Area
1Units
General warehouse · Owner of record: BK 60 REALTY LLC · 5,120 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralGeneral
Floor 14p · 2 filings · 10 docs
Site & exterior6p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
718OUTDOOR507/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/17/2024$2.0M—— → —$391/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN FENG, ARCHITECT108/01/2024
MURDOCH ENGINEERING211/07/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
R MANETTA203/21/2026
HIGH QUALITY 338203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor307/08/2026
L.S. SIGN CO., INCGeneral Contractor107/08/2026
L S SIGNScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244108/01/2024
SQ. ARCH, LLC4802108/01/2024
Building Lifecycle
All (19)Filed (3)Permit Issued (4)Signed Off (3)Special Inspection (9)
09/18/2024
Signed off — Alteration
JOB IS FILED TO GENERAL CONSTRUCTION & MECHANICAL FOR EX. WAREHOUSE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01087889-I1
08/22/2024
Permit issued — General Construction
B01087889-I1-MS
08/22/2024
Permit issued — General Construction
B01087889-I1-GC
08/01/2024
Filed — Alteration
JOB IS FILED TO GENERAL CONSTRUCTION & MECHANICAL FOR EX. WAREHOUSE. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01087889-I1
07/30/2024
Special inspection requirement — Maintenance information
Chun Feng
07/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
Chun Feng
07/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Chun Feng
07/30/2024
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
07/30/2024
Special inspection requirement — Fire-Resistance Rated Construction
Chun Feng
07/30/2024
Special inspection requirement — HVAC-R and service water heating system controls
Chun Feng
07/30/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Chun Feng
07/29/2024
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
07/29/2024
Special inspection requirement — Final
Chun Feng
11/18/2020
Signed off — Alteration
B00253600-I1
11/18/2020
Signed off — Alteration
B00253607-I1
08/25/2020
Permit issued — Structural
B00253607-I1-ST
11/07/2019
Filed — Alteration
B00253600-I1
11/07/2019
Filed — Alteration
B00253607-I1
11/07/2019
Permit issued — Sign
B00253600-I1-SG
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION08/22/2024
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION08/22/2024
DOB NOWStructuralSigned-offL.S. SIGN CO., INC08/25/2020
DOB NOWSignSigned-offTRU-ART SIGN CO. INC11/07/2019
BISPLISSUEDADCO PLUMBING AND HEATING01/28/1997
BISEQISSUEDJBI RENOVATION INC06/10/1996
1 project · most recent 11/15/2022
FiledStatusContractorScope
11/15/2022Permit IssuedJOSEPH WEINSTEIN ELECTRIC1 meters
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
07/30/2024Maintenance informationChun Fengenergy_progress
07/30/2024HVAC-R and service water heating equipmentChun Fengenergy_progress
07/30/2024Fire-Resistant Penetrations and JointsChun Fengspecial
07/30/2024Energy Code Compliance InspectionsChun Fengprogress
07/30/2024Fire-Resistance Rated ConstructionChun Fengprogress
07/30/2024HVAC-R and service water heating system controlsChun Fengenergy_progress
07/30/2024HVAC-R and service water piping design and insulationChun Fengenergy_progress
07/29/2024Mechanical SystemsNARESH MAHANGUspecial
07/29/2024FinalChun Fengprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch1
08/24/2026B01087889-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sign1
09/02/2026B00253600-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
09/02/2026B00253607-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B00253600-I1Open ↗
08/13/2026B00253607-I1Open ↗
08/13/2026B01087889-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/30/2026B01087889-I1Open ↗
08/30/2026B01087889-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026B01087889-I1Open ↗
08/30/2026B01087889-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026B00253600-I1Open ↗
08/13/2026B01087889-I1Open ↗
08/13/2026B00253607-I1Open ↗