← Back
Predominantly retail with other uses
82-19 NORTHERN BOULEVARD
QUEENS · Jackson Heights · BIN 4034492
💬 Discuss this project
1938Year Built
3Stories
K4Building Class
R4Zoning
7,175 sfGross Floor Area
1Units
7 Open Violations 6 unresolved · 1 paperwork only ▸
Predominantly retail with other uses · Owner of record: 82-19 NB LLC · 2,492 sf lot · 2.88 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof8p · 4 filings · 20 docs
Floor 315p · 2 filings · 20 docs
Floor 216p · 3 filings · 20 docs
Floor 116p · 3 filings · 20 docs
Cellar21p · 5 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
82-19 NB6909/01/2026
SAFE-SHIELD ENTERPRISES1007/08/2026
CELATECH CONSTRUCTION COR603/22/2026
CONSTRUCTION COR CELATECH303/22/2026
COR CELATECH CONSTRUCTION303/22/2026
SAFE-SHEILD ENTERPRISE IN103/22/2026
ECI CONWAY INC103/22/2026
SERVICE CORP INC203/21/2026
SERVICE CORP203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/04/2021$2.3M—SCI FUNERAL SERVICES OF NEW YORK, INC → 82-19 NB LLC$318/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRANK PETRUSO ARCHITECT PC607/23/2026
NAUDUS PROFESSIONAL ENGINEERING705/14/2026
VATCHE GHAZARIAN, PE611/05/2024
ASHRAF CORP204/28/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FRANK PETRUSORA AOL COM803/21/2026
DANICO SERVICES403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CELATECH CONSTRUCTION CORGeneral Contractor5007/08/2026
SAFE-SHEILD ENTERPRISE INGeneral Contractor607/08/2026
MORELL BUILDERS INCGeneral Contractor303/21/2026
JUST PLBG & HTG INCPlumbing207/04/2026
KWONG MING ELECTRIC INCElectrical103/22/2026
AQUEDUCT MECHANICAL CORPFire Protection107/02/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IP CONCRETE TESTING AND I62522007/23/2026
Building Lifecycle
All (165)Filed (21)Permit Issued (39)Signed Off (6)Violation (30)Inspection (12)Objection (27)Special Inspection (30)
07/23/2026
Filed — Alteration CO
INTERIOR AND EXTERIOR RENOVATION OF EXISTING BUILDING TO INCLUDE CONVERTING CELLAR AND 1ST FLOOR INTO EATING AND DRINKING ESTABLISHMENT. SECOND FLOOR TO OFFICE SPACE AND THIRD FLOOR RENOVATE/ALTER EXISTING DWELLING UNITS.
Q00678351-P2
07/08/2026
Special inspection requirement — Masonry
INDARDEO PARBHUNATH
07/08/2026
Special inspection requirement — Fenestration air leakage
Vatche Ghazarian
07/08/2026
Special inspection requirement — Air barrier - visual inspection
Vatche Ghazarian
07/08/2026
Special inspection requirement — Insulation placement and R values
Vatche Ghazarian
07/08/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
INDARDEO PARBHUNATH
07/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
07/08/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Vatche Ghazarian
07/08/2026
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
INDARDEO PARBHUNATH
05/18/2026
Special inspection requirement — HVAC-R and service water heating equipment
Vatche Ghazarian
05/18/2026
Special inspection requirement — Interior lighting power
Vatche Ghazarian
05/18/2026
Special inspection requirement — Final
Vatche Ghazarian
05/18/2026
Special inspection requirement — Maintenance information
Vatche Ghazarian
05/18/2026
Special inspection requirement — Lighting controls
Vatche Ghazarian
05/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Vatche Ghazarian
05/18/2026
Special inspection requirement — Shutoff dampers
Vatche Ghazarian
05/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
05/18/2026
Special inspection requirement — Mechanical Systems
INDARDEO PARBHUNATH
05/18/2026
Special inspection requirement — HVAC-R and service water heating system controls
Vatche Ghazarian
05/18/2026
Special inspection requirement — Energy Code Compliance Inspections
Vatche Ghazarian
05/14/2026
Filed — Alteration
Adding split air-conditioning units, electric heaters, and fans for restaurant, apartments, and office space.
Q08033276-P1
05/08/2026
Inspection — Fail-Final Boiler Equipment Inspection
Fail
View inspection ↗
03/30/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/20/2026
Inspection — Fail-Final Boiler Equipment Inspection
Fail
View inspection ↗
03/06/2026
Objection resolved — Addressed
01/07/2026
Permit issued — General Construction
Q00678351-I1-GC
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/11/2025
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES, KITCHEN EQUIPMENT, DOMESTIC WATER, GAS AND SANITARY SYSTEMS, ROUGH-INS AND NEW CONNECTIONS TO EXISTING PLUMBING PIPING SYSTEMS. NEW SPRINKLER SYSTEM FOR 3 STORY (AND CELLAR AND ROOF) MIXED USE BUILDING
Q08033751-P4
10/11/2025
Special inspection requirement — Post-installed Anchors
INDARDEO PARBHUNATH
10/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
10/11/2025
Special inspection requirement — Sprinkler Systems
INDARDEO PARBHUNATH
10/02/2025
Special inspection requirement — Air barrier - visual inspection
Vatche Ghazarian
10/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
10/02/2025
Special inspection requirement — Masonry
INDARDEO PARBHUNATH
10/02/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
INDARDEO PARBHUNATH
10/02/2025
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
INDARDEO PARBHUNATH
10/02/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Vatche Ghazarian
10/02/2025
Special inspection requirement — Fenestration air leakage
Vatche Ghazarian
10/02/2025
Special inspection requirement — Insulation placement and R values
Vatche Ghazarian
10/01/2025
Objection resolved — Addressed
09/25/2025
Objection raised — Other
09/19/2025
Filed — Alteration CO
INTERIOR AND EXTERIOR RENOVATION OF EXISTING BUILDING TO INCLUDE CONVERTING CELLAR AND 1ST FLOOR INTO EATING AND DRINKING ESTABLISHMENT. SECOND FLOOR TO OFFICE SPACE AND THIRD FLOOR RENOVATE/ALTER EXISTING DWELLING UNITS.
Q00678351-P1
09/18/2025
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES, KITCHEN EQUIPMENT, DOMESTIC WATER, GAS AND SANITARY SYSTEMS, ROUGH-INS AND NEW CONNECTIONS TO EXISTING PLUMBING PIPING SYSTEMS. NEW SPRINKLER SYSTEM FOR 3 STORY (AND CELLAR AND ROOF) MIXED USE BUILDING
Q08033751-P3
09/18/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/15/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/10/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/04/2025
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES, KITCHEN EQUIPMENT, DOMESTIC WATER, GAS AND SANITARY SYSTEMS, ROUGH-INS AND NEW CONNECTIONS TO EXISTING PLUMBING PIPING SYSTEMS. NEW SPRINKLER SYSTEM FOR 3 STORY (AND CELLAR AND ROOF) MIXED USE BUILDING
Q08033751-P2
07/31/2025
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES, KITCHEN EQUIPMENT, DOMESTIC WATER, GAS AND SANITARY SYSTEMS, ROUGH-INS AND NEW CONNECTIONS TO EXISTING PLUMBING PIPING SYSTEMS. NEW SPRINKLER SYSTEM FOR 3 STORY (AND CELLAR AND ROOF) MIXED USE BUILDING
Q08033751-P1
07/22/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
07/17/2025
Violation issued (ECB, open)
Boilers
05/22/2025
Objection resolved — Addressed
04/25/2025
Objection raised — Fire_Protection
04/25/2025
Objection raised — Fire_Protection
04/25/2025
Objection raised — Fire_Protection
04/10/2025
Filed — No Work
Q01198473-I1
12/18/2024
Signed off — Alteration
Q00636516-I1
12/16/2024
Signed off — Alteration
Q00792534-I1
12/16/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/29/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/14/2024
Signed off — Alteration
HEREWITH FILED FOR INTERIOR STRUCTURAL FRAMING AND UNDERPINNING IN CONJUNCTION WITH ALT 1 DOB JOB NO Q00678351
Q00765701-I1
Latest 60 of 165 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR01/07/2026
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR11/12/2024
DOB NOWPlumbingSigned-offMOHAMED ABDELRAZEK09/26/2024
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR05/31/2024
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR04/25/2024
DOB NOWConstruction FenceSigned-offCELATECH CONSTRUCTION COR04/25/2024
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR04/23/2024
DOB NOWPlumbingSigned-offAQUEDUCT MECHANICAL CORP01/25/2024
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR05/18/2023
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR05/16/2023
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR05/16/2023
DOB NOWConstruction FenceSigned-offCELATECH CONSTRUCTION COR05/15/2023
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR05/15/2023
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR04/27/2023
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR04/25/2023
DOB NOWConstruction FenceSigned-offCELATECH CONSTRUCTION COR04/24/2023
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR04/24/2023
DOB NOWMechanical SystemsSigned-offCELATECH CONSTRUCTION COR04/24/2023
DOB NOWStructuralSigned-offCELATECH CONSTRUCTION COR03/22/2023
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR03/22/2023
DOB NOWConstruction FenceSigned-offCELATECH CONSTRUCTION COR03/10/2023
DOB NOWMechanical SystemsSigned-offCELATECH CONSTRUCTION COR03/09/2023
DOB NOWFoundationSigned-offCELATECH CONSTRUCTION COR03/09/2023
DOB NOWFoundationSigned-offCELATECH CONSTRUCTION COR03/09/2023
DOB NOWStructuralSigned-offCELATECH CONSTRUCTION COR03/09/2023
DOB NOWSupported ScaffoldSigned-offSAFE-SHEILD ENTERPRISE IN02/06/2023
DOB NOWFoundationSigned-offCELATECH CONSTRUCTION COR02/03/2023
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR02/03/2023
DOB NOWSprinklersSigned-offMOHAMED ABDELRAZEK01/24/2023
DOB NOWSidewalk ShedSigned-offSAFE-SHEILD ENTERPRISE IN01/06/2023
DOB NOWFoundationSigned-offCELATECH CONSTRUCTION COR01/04/2023
DOB NOWMechanical SystemsSigned-offCELATECH CONSTRUCTION COR01/04/2023
DOB NOWConstruction FenceSigned-offCELATECH CONSTRUCTION COR09/13/2022
DOB NOWGeneral ConstructionPermit IssuedCELATECH CONSTRUCTION COR08/04/2022
DOB NOWStructuralSigned-offCELATECH CONSTRUCTION COR08/03/2022
DOB NOWGeneral ConstructionSigned-offCELATECH CONSTRUCTION COR05/06/2022
DOB NOWSupported ScaffoldSigned-offSAFE-SHEILD ENTERPRISE IN04/29/2022
DOB NOWSidewalk ShedSigned-offSAFE-SHEILD ENTERPRISE IN04/22/2022
DOB NOWGeneral ConstructionSigned-offMORELL BUILDERS INC02/23/2022
BISMHISSUEDAIRDEX INC09/09/2004
+ 1 more permits on file
1 project · most recent 05/14/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/14/2026Signed-offCELATECH CONSTRUCTION CORHeating and Air Conditioning Systems
Heat / Cool
Gree GMW-96WM/B-F(U) 92,000 BTU · Vrf Outdoor ×4
GMV-Q96WM/B-F(U) 96,000 BTU · Vrf Outdoor ×2
MUL24HP230VIR32A0 24,000 BTU · Condensing Unit ×2
MUL30HP230VIR32A0 30,000 BTU · Condensing Unit ×2
Midea MO4EX-H27B-2A 24,000 BTU · Vrf Outdoor ×4
1 project · most recent 10/11/2025
FiledStatusContractorScope
10/11/2025Signed-offAQUEDUCT MECHANICAL CORP270 heads
1 project · most recent 10/11/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/11/2025Signed-off2M MECHANICAL LLCGas, Storm, Water/Sanitary
2 projects · most recent 05/28/2026
General Wiring
FiledStatusContractorScope
05/28/2026CompleteQEC ELECTRICAL SVCE CORPGeneral Wiring
05/16/2023Permit IssuedKWONG MING ELECTRIC INC—
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
05/08/2026Fail-Final Boiler Equipment InspectionFailView ↗
03/30/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/20/2026Fail-Final Boiler Equipment InspectionFailView ↗
09/18/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/15/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/10/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/22/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
12/16/2024Pass-Final General Construction Non-Directive 14PassView ↗
11/29/2024Fail-Final General Construction Non-Directive 14FailView ↗
01/02/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/28/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/21/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 68
DateRequirementInspectorRole
07/08/2026Wall Panels, Curtain Walls, and VeneersINDARDEO PARBHUNATHspecial
07/08/2026Air barrier - visual inspectionVatche Ghazarianenergy_progress
07/08/2026Fenestration and door U-factor and product ratingsVatche Ghazarianenergy_progress
07/08/2026MasonryINDARDEO PARBHUNATHspecial
07/08/2026Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
07/08/2026Exterior Insulation and Finish Systems (EIFS)INDARDEO PARBHUNATHspecial
07/08/2026Fenestration air leakageVatche Ghazarianenergy_progress
07/08/2026Insulation placement and R valuesVatche Ghazarianenergy_progress
05/18/2026HVAC-R and service water heating equipmentVatche Ghazarianenergy_progress
05/18/2026HVAC-R and service water heating system controlsVatche Ghazarianenergy_progress
05/18/2026Interior lighting powerVatche Ghazarianenergy_progress
05/18/2026Lighting controlsVatche Ghazarianenergy_progress
05/18/2026Shutoff dampersVatche Ghazarianenergy_progress
05/18/2026HVAC-R and service water piping design and insulationVatche Ghazarianenergy_progress
05/18/2026Maintenance informationVatche Ghazarianenergy_progress
05/18/2026FinalVatche Ghazarianprogress
05/18/2026Energy Code Compliance InspectionsVatche Ghazarianprogress
05/18/2026Mechanical SystemsINDARDEO PARBHUNATHspecial
05/18/2026Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
10/11/2025Sprinkler SystemsINDARDEO PARBHUNATHspecial
10/11/2025Post-installed AnchorsINDARDEO PARBHUNATHspecial
10/11/2025Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
10/02/2025Air barrier - visual inspectionVatche Ghazarianenergy_progress
10/02/2025Fenestration and door U-factor and product ratingsVatche Ghazarianenergy_progress
10/02/2025Insulation placement and R valuesVatche Ghazarianenergy_progress
Latest 25 of 68.
▾Documents — 137 on file (BIS + DOB NOW)
▸Plans & Drawings21
▸DOB NOWPlans/Sketch20
08/27/2026Q00636516-I1Request digital key ↗
08/26/2026Q00721892-I1Request digital key ↗
08/26/2026Q00721897-I1Request digital key ↗
Showing 3 of 20 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly1
08/15/2026Q01198473-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZoning Exhibit form (1-5)1
08/18/2026Q00678351-P2Open ↗
▸Seals & Professional Certifications88
▸DOB NOWSpecial Inspector Seal & Signature42
09/01/2026Q00765701-P1Open ↗
09/01/2026Q00765701-P1Open ↗
09/01/2026Q00765701-P1Open ↗
Showing 3 of 42 on file for this type
▸DOB NOWProgress Inspector Seal & Signature25
09/01/2026Q00765701-P1Open ↗
09/01/2026Q00765701-P1Open ↗
08/31/2026Q00765701-P4Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature21
08/27/2026Q00636516-I1Open ↗
08/26/2026Q00721897-I1Open ↗
08/26/2026Q00746790-I1Open ↗
Showing 3 of 21 on file for this type
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist3
08/18/2026Q00678351-P2Open ↗
08/15/2026Q00678351-P1Open ↗
08/14/2026Q00678351-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00678351-I1Open ↗
▸Environmental & Asbestos17
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
08/27/2026Q00636516-I1Open ↗
08/26/2026Q00746790-I1Open ↗
08/21/2026Q00765701-I1Open ↗
Showing 3 of 17 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/14/2026Q00678351-I1Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification3
08/18/2026Q00678351-P2Open ↗
08/15/2026Q00678351-P1Open ↗
08/14/2026Q00678351-I1Open ↗
▸DOB NOWProject Specific General Liability (PGL1)1
08/13/2026Q00678351-I1Open ↗
▸DOB NOWDOB Form (from plan PDF)1
08/16/2026Q00765701-P1Open ↗