| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 06/27/2019 | $727K | — | Private party → Private party | $279/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ANAND J. SOLANKI, P.E. | 3 | 07/24/2022 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| DRM CONSTRUCTION CORP | General Contractor | 20 | 07/08/2026 |
| CUSTOMBUILT HOMES INC | General Contractor | 2 | 03/21/2026 |
| MOTTES, STEVE | Electrical | 1 | 03/21/2026 |
| SANDHA GENERAL CONTRACTIN | Electrical | 1 | 03/21/2026 |
| HORBRIDGE PLUMBING & HEATING | Plumbing | 1 | 07/08/2026 |
| M & M PIPING AND HEATING | Plumbing | 1 | 06/28/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ANAND J. SOLANKI, P.E. | 3662 | 2 | 07/24/2022 |
| TRIANGLE INSPECTION & TES | 7495 | 1 | 07/24/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | M & M PIPING AND HEATING | 02/10/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | CUSTOMBUILT HOMES INC | 12/03/2024 |
| DOB NOW | Construction Fence | Permit Issued | DRM CONSTRUCTION CORP | 06/06/2023 |
| DOB NOW | General Construction | Permit Issued | DRM CONSTRUCTION CORP | 05/04/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | DRM CONSTRUCTION CORP | 01/10/2023 |
| DOB NOW | Construction Fence | Permit Issued | DRM CONSTRUCTION CORP | 01/10/2023 |
| DOB NOW | Foundation | Permit Issued | DRM CONSTRUCTION CORP | 09/23/2022 |
| DOB NOW | Sprinklers | Permit Issued | HORBRIDGE PLUMBING & HEAT | 09/21/2022 |
| DOB NOW | Construction Fence | Permit Issued | DRM CONSTRUCTION CORP | 09/01/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | DRM CONSTRUCTION CORP | 06/08/2022 |
| DOB NOW | Construction Fence | Permit Issued | DRM CONSTRUCTION CORP | 03/07/2022 |
| BIS | OT | ISSUED | THEODORE WAGNER PLG | 09/14/2000 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/22/2021 | Permit Issued | CUSTOMBUILT HOMES INC | Air Conditioning Systems, Heating Systems | Cooling Lennox CBA27UHE-036-230-6-01 3 tons · Fan Coil Indoor ×2 Luxaire TC3B4221HA 3 tons · Condensing Unit ×2 Heating Weil-Mclain GV90+6 175,000 BTU · Boiler ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/04/2022 | Permit Issued | BDS ELECTRIC CORP. | General Wiring, Lighting |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/22/2021 | Permit Issued | CUSTOMBUILT HOMES INC | 1 scope_items |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/02/2021 | Permit Issued | DRM CONSTRUCTION CORP | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/22/2021 | Permit Issued | CUSTOMBUILT HOMES INC | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/15/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 04/23/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 03/20/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/20/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 02/18/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/23/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 12/23/2022 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 12/23/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 12/23/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/23/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 11/20/2021 | Electric vehicle service equipment requirements | Anand Solanki | energy_progress |
| 03/29/2021 | Subsurface Investigations (Borings/Test Pits) | Rajasekhar Sakhamuri | special |
| 03/29/2021 | Interior lighting power | Anand Solanki | energy_progress |
| 03/29/2021 | Air barrier — testing | Anand Solanki | energy_progress |
| 03/28/2021 | Fire-Resistant Penetrations and Joints | Anand Solanki | special |
| 03/28/2021 | Heating Systems | Anand Solanki | special |
| 03/28/2021 | Masonry | Anand Solanki | special |
| 03/28/2021 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Anand Solanki | special |
| 03/28/2021 | Structural Steel - High Strength Bolting | Anand Solanki | special |
| 03/28/2021 | Structural Steel - Welding | Anand Solanki | special |
| 03/28/2021 | Subgrade Inspections | Anand Solanki | special |
| 03/28/2021 | Final | Anand Solanki | progress |
| 03/28/2021 | Footing and Foundation | Anand Solanki | progress |
| 03/28/2021 | Energy Code Compliance Inspections | Anand Solanki | progress |
| 03/28/2021 | Fire-Resistance Rated Construction | Anand Solanki | progress |
| 03/28/2021 | Fenestration areas | Anand Solanki | energy_progress |
| 03/28/2021 | Protection of exposed foundation insulation | Anand Solanki | energy_progress |
| 03/28/2021 | Air barrier - visual inspection | Anand Solanki | energy_progress |
| 03/28/2021 | Insulation placement and R values | Anand Solanki | energy_progress |
| 03/28/2021 | Duct leakage testing, insulation and design | Anand Solanki | energy_progress |
| 03/28/2021 | Maintenance information | Anand Solanki | energy_progress |
| 03/28/2021 | Fenestration air leakage | Anand Solanki | energy_progress |
| 03/28/2021 | Metering | Anand Solanki | energy_progress |
| 03/28/2021 | Fenestration and door U-factor and product ratings | Anand Solanki | energy_progress |
| 03/28/2021 | HVAC-R and service water heating equipment | Anand Solanki | energy_progress |