← Back
Two family converted from one family
82-79 164 PLACE
QUEENS · BIN 4152547
💬 Discuss this project
1955Year Built
2Stories
B3Building Class
R4BZoning
1,480 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,088 sf lot · 0.71 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 21p · 1 filing · 20 docs
Floor 11 filing · 20 docs
Cellar5p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/27/2022$733K—Private party → Private party$495/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FLUSHING ENGINEERING SERVICE PC507/21/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M2 DESIGN1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A ELECTRICAL MAIN SVC INCElectrical103/22/2026
RONG MAINTENANCE INCGeneral Contractor107/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FLUSHING ENGINEERING SERV4373507/21/2023
Building Lifecycle
All (39)Filed (5)Permit Issued (2)Signed Off (1)Violation (3)Inspection (4)Objection (12)Special Inspection (12)
05/03/2025
Violation issued (HPD, closed)
B
05/03/2025
Violation issued (HPD, closed)
B
05/03/2025
Violation issued (HPD, closed)
A
11/17/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/29/2023
Signed off — Alteration CO
interior renovation of existing bldg, Install partitions, door, accessory stair to cellar, plumbing work in cellar, 1st , 2nd floor. and convert existing one family into two family. required new c of o for two family
Q08016083-S1
07/21/2023
Filed — Alteration CO
interior renovation of existing bldg, Install partitions, door, accessory stair to cellar, plumbing work in cellar, 1st , 2nd floor. and convert existing one family into two family. required new c of o for two family
Q08016083-P3
07/20/2023
Special inspection requirement — Mechanical Systems
KY FU
07/20/2023
Special inspection requirement — Final
KY FU
07/17/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/17/2023
Filed — Alteration CO
interior renovation of existing bldg, Install partitions, door, accessory stair to cellar, plumbing work in cellar, 1st , 2nd floor. and convert existing one family into two family. required new c of o for two family
Q08016083-P2
06/12/2023
Special inspection requirement — Final
KY FU
06/12/2023
Special inspection requirement — Mechanical Systems
KY FU
02/16/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/16/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/08/2023
Special inspection requirement — HVAC-R and service water heating system controls
KY FU
02/08/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
KY FU
02/08/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
02/08/2023
Special inspection requirement — HVAC-R and service water heating equipment
KY FU
02/07/2023
Filed — Alteration CO
interior renovation of existing bldg, Install partitions, door, accessory stair to cellar, plumbing work in cellar, 1st , 2nd floor. and convert existing one family into two family. required new c of o for two family
Q08016083-P1
02/03/2023
Special inspection requirement — HVAC-R and service water heating system controls
KY FU
02/03/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
KY FU
02/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
KY FU
02/03/2023
Special inspection requirement — HVAC-R and service water heating equipment
KY FU
12/09/2022
Permit issued — Mechanical Systems
Q08016083-I1-GC-CX
12/05/2022
Permit issued — Plumbing
Q08016083-S1-PL
11/15/2022
Filed — Alteration CO
interior renovation of existing bldg, Install partitions, door, accessory stair to cellar, plumbing work in cellar, 1st , 2nd floor. and convert existing one family into two family. required new c of o for two family
Q08016083-S1
10/28/2022
Objection raised — Mechanical
10/28/2022
Objection resolved — Addressed
10/27/2022
Objection raised — Fire_Protection
10/27/2022
Objection resolved — Addressed
10/27/2022
Objection raised — Fire_Protection
10/27/2022
Objection resolved — Addressed
10/27/2022
Objection raised — Other
10/27/2022
Objection resolved — Addressed
10/27/2022
Objection raised — Admin
10/27/2022
Objection resolved — Addressed
10/17/2022
Objection raised — Energy
10/17/2022
Objection resolved — Addressed
10/13/2022
Filed — Alteration CO
interior renovation of existing bldg, Install partitions, door, accessory stair to cellar, plumbing work in cellar, 1st , 2nd floor. and convert existing one family into two family. required new c of o for two family
Q08016083-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedRONG MAINTENANCE INC12/09/2022
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC12/05/2022
1 project · most recent 07/21/2023
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/21/2023Permit IssuedRONG MAINTENANCE INCAir Conditioning Systems, Ventilation Systems
Cooling
Daikin 3MXS24RMVJUA ,4MXS36RMVJUA 9,000 CFM · Vrf Outdoor ×4
Ventilation
Panasonic PANASONIC 70 CFM ×18
1 project · most recent 07/19/2023
General Wiring
FiledStatusContractorScope
07/19/2023CompleteA ELECTRICAL MAIN SVC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/17/2023Pass-Final CND-Occupancy InspectionPassView ↗
07/17/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/16/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/16/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
07/20/2023Mechanical SystemsKY FUspecial
07/20/2023FinalKY FUprogress
06/12/2023FinalKY FUprogress
06/12/2023Mechanical SystemsKY FUspecial
02/08/2023HVAC-R and service water heating system controlsKY FUenergy_progress
02/08/2023HVAC-R and service water piping design and insulationKY FUenergy_progress
02/08/2023Fire-Resistant Penetrations and JointsKY FUspecial
02/08/2023HVAC-R and service water heating equipmentKY FUenergy_progress
02/03/2023HVAC-R and service water heating system controlsKY FUenergy_progress
02/03/2023HVAC-R and service water piping design and insulationKY FUenergy_progress
02/03/2023Fire-Resistant Penetrations and JointsKY FUspecial
02/03/2023HVAC-R and service water heating equipmentKY FUenergy_progress
▾Documents — 35 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/25/2026Q08016083-S1Request digital key ↗
08/25/2026Q08016083-P2Request digital key ↗
08/25/2026Q08016083-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q08016083-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
08/31/2026Q08016083-P3Open ↗
08/29/2026Q08016083-S1Open ↗
08/29/2026Q08016083-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026Q08016083-I1Open ↗
08/25/2026Q08016083-S1Open ↗
08/25/2026Q08016083-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026Q08016083-P3Open ↗
08/29/2026Q08016083-S1Open ↗
08/29/2026Q08016083-P1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/25/2026Q08016083-P2Open ↗
08/14/2026Q08016083-I1Open ↗
08/13/2026Q08016083-P3Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026Q08016083-S1Open ↗
08/25/2026Q08016083-P2Open ↗
08/14/2026Q08016083-I1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/25/2026Q08016083-P2Open ↗
08/14/2026Q08016083-I1Open ↗
08/13/2026Q08016083-P3Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q08016083-I1Open ↗