← Back
BuildNYC
Two family frame
82 WOODLAND AVENUE
STATEN ISLAND · BIN 5171770
💬 Discuss this project
2021Year Built
2Stories
B2Building Class
R3AZoning
2,297 sfGross Floor Area
2Units
Two family frame · 4,842 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingCivil
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 2Automatic sprinkler system installation8p · 3 filings · 20 docs
Floor 1Automatic sprinkler system installation8p · 3 filings · 20 docs
Cellar1p · 1 filing · 20 docs
Sub-BasementAutomatic sprinkler system installation8p · 3 filings · 20 docs
Site & exteriorTemporary construction fence installation10p · 4 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Think Design Architecture510/24/2022
A Tech Engineering NYC102/28/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A Tech Engineering NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Superior Plumbing & HeatingPlumbing507/08/2026
Cee Jay Real Estate DevelopmentScaffold407/08/2026
Cee Jay Real Estate DevelopmentGeneral Contractor303/21/2026
Quality PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A Tech Engineering NYC, P6738210/24/2022
SRA Planning & Expediting5677104/23/2020
Building Lifecycle
11/18/2022
Signed off — Alteration
APPLICATION FILED FOR PLUMBING WORK ASSOCIATED TO NEW BUILDING APPLICATION #520383736 (HOUSE) AND #520396535 (DETACHED GARAGE).
S00293377-I1
10/25/2022
Special inspection requirement — HVAC insulation and sealing
WILLIAM MONTAGUE
10/25/2022
Special inspection requirement — HVAC and service water heating equipment
WILLIAM MONTAGUE
10/25/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
WILLIAM MONTAGUE
10/25/2022
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM MONTAGUE
51 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSuperior Plumbing & Heating09/21/2022
DOB NOWPlumbingSigned-offSuperior Plumbing & Heating09/21/2022
DOB NOWCurb CutSigned-offStructuretech NY06/08/2022
DOB NOWConstruction FenceSigned-offStructuretech NY01/12/2022
DOB NOWPlumbingSigned-offSuperior Plumbing & Heating08/24/2021
DOB NOWPlumbingSigned-offSuperior Plumbing & Heating08/11/2021
DOB NOWPlumbingSigned-offSuperior Plumbing & Heating08/11/2021
DOB NOWPlumbingSigned-offQuality Plumbing06/28/2021
DOB NOWConstruction FenceSigned-offStructuretech NY01/17/2021
DOB NOWConstruction FenceSigned-offStructuretech NY08/28/2019
BIS—ISSUEDCee Jay Real Estate Development11/08/2022
BIS—ISSUEDCee Jay Real Estate Development09/08/2022
BIS—ISSUEDCee Jay Real Estate Development01/04/2022
BIS—ISSUEDCee Jay Real Estate Development09/09/2021
BIS—ISSUEDCee Jay Real Estate Development10/13/2020
2 projects · most recent 11/21/2022
General Wiring
FiledStatusContractorScope
11/21/2022CompleteEmpire 1 ElectricalGeneral Wiring
09/26/2022CancelledEmpire 1 ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
10/03/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/27/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/22/2022Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
09/21/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/19/2022Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
06/13/2022Pass-Final Curb Cut Non-Directive 14PassView ↗
12/17/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/17/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/30/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/03/2021Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
07/27/2021Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
10/25/2022HVAC insulation and sealing WILLIAM MONTAGUEenergy_progress
10/25/2022HVAC and service water heating equipment WILLIAM MONTAGUEenergy_progress
10/25/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationWILLIAM MONTAGUEspecial
10/25/2022Energy Code Compliance InspectionsWILLIAM MONTAGUEprogress
10/25/2022Maintenance informationWILLIAM MONTAGUEenergy_progress
10/25/2022HVAC and service water heating system controls WILLIAM MONTAGUEenergy_progress
10/20/2022HVAC and service water heating system controls anthony santoroenergy_progress
10/20/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installationanthony santorospecial
10/20/2022Energy Code Compliance Inspectionsanthony santoroprogress
10/20/2022HVAC insulation and sealing anthony santoroenergy_progress
10/20/2022Maintenance informationanthony santoroenergy_progress
10/20/2022HVAC and service water heating equipment anthony santoroenergy_progress
05/04/2022HVAC insulation and sealing anthony santoroenergy_progress
05/04/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installationanthony santorospecial
05/04/2022Energy Code Compliance Inspectionsanthony santoroprogress
05/04/2022Maintenance informationanthony santoroenergy_progress
05/04/2022HVAC and service water heating equipment anthony santoroenergy_progress
05/04/2022HVAC and service water heating system controls anthony santoroenergy_progress
06/26/2019FinalFrank Martarella IIIprogress
45 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account