← Back
Two stories - detached, small or mid-size
8205 NARROWS AVENUE
BROOKLYN · BIN 3151964
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R2Zoning
2,510 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 5,000 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivil
Floor 265p · 2 filings · 20 docs
Floor 161p · 2 filings · 20 docs
Cellar52p · 1 filing · 20 docs
Basement18p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DIMEX GROUP203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/15/2021$1.9M—Private party → Private party$753/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M JUST ARCHITECTURE PC608/01/2024
RLM ENGINEERING PLLC505/24/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JUST ARCHITECTURE2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DIMEX GROUP INCGeneral Contractor1007/08/2026
CITY PLUMBING INCPlumbing407/08/2026
CITY PLUMBINGGeneral Contractor203/22/2026
LENS ELECTRIC, INCElectrical103/22/2026
STANISLAV UMANSKIYElectrical103/21/2026
SHELBY ELECTRICAL CORP 005280General Contractor103/22/2026
MICHAEL D JUSTElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KALLASSY ENGINEERING PLLC57111008/01/2024
Building Lifecycle
All (83)Filed (11)Permit Issued (8)Signed Off (2)Violation (2)Inspection (6)Objection (24)Special Inspection (30)
08/13/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Joseph El-kallassy
08/13/2024
Special inspection requirement — HVAC-R and service water heating equipment
Joseph El-kallassy
08/13/2024
Special inspection requirement — Subgrade Inspections
Joseph El-kallassy
08/13/2024
Special inspection requirement — Air barrier - visual inspection
Joseph El-kallassy
08/13/2024
Special inspection requirement — Maintenance information
Joseph El-kallassy
08/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joseph El-kallassy
08/13/2024
Special inspection requirement — Structural Steel - Welding
Joseph El-kallassy
08/13/2024
Special inspection requirement — Concrete - Cast-In-Place
Joseph El-kallassy
08/13/2024
Special inspection requirement — Footing and Foundation
Joseph El-kallassy
08/13/2024
Special inspection requirement — Interior lighting power
Joseph El-kallassy
08/13/2024
Special inspection requirement — HVAC-R and service water heating system controls
Joseph El-kallassy
08/13/2024
Special inspection requirement — Insulation placement and R values
Joseph El-kallassy
08/13/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Younes Abouyaala
08/13/2024
Special inspection requirement — Fenestration air leakage
Joseph El-kallassy
08/13/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Joseph El-kallassy
08/13/2024
Special inspection requirement — Mechanical Systems
Joseph El-kallassy
08/13/2024
Special inspection requirement — Structural Steel - Details
Joseph El-kallassy
08/13/2024
Special inspection requirement — Structural Cold-Formed Steel
Joseph El-kallassy
08/13/2024
Special inspection requirement — Final
Joseph El-kallassy
08/13/2024
Special inspection requirement — Energy Code Compliance Inspections
Joseph El-kallassy
08/13/2024
Special inspection requirement — Fire-Resistance Rated Construction
Joseph El-kallassy
08/13/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Joseph El-kallassy
08/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Joseph El-kallassy
08/13/2024
Special inspection requirement — Fenestration areas
Joseph El-kallassy
08/13/2024
Special inspection requirement — Permanent certificate
Joseph El-kallassy
08/01/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
To renovate existing detached 1 family dwelling.
B00626121-P4
07/26/2024
Special inspection requirement — Final
Joseph El-kallassy
07/26/2024
Special inspection requirement — Energy Code Compliance Inspections
Joseph El-kallassy
07/26/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
ALBERTO ROMAN
07/26/2024
Special inspection requirement — Fenestration air leakage
Joseph El-kallassy
07/26/2024
Special inspection requirement — Subgrade Inspections
Joseph El-kallassy
07/25/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/24/2024
Signed off — Alteration
B00541795-I1
07/01/2024
Objection resolved — Addressed
06/14/2024
Signed off — Alteration
B00548904-I1
05/24/2024
Filed — Alteration
B00541795-P4
04/26/2024
Permit issued — Plumbing
B00541795-I1-PL
04/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/19/2024
Filed — Alteration
B00541795-P3
04/18/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/15/2024
Objection raised — Zoning
04/08/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
To renovate existing detached 1 family dwelling.
B00626121-P3
03/11/2024
Permit issued — Foundation
B00626121-I1-GC-CX
05/21/2023
Permit issued — Construction Fence
B00548904-I1-FN
05/02/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/28/2023
Permit issued — Plumbing
B00541795-I1-PL
04/25/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/15/2023
Filed — Alteration
B00541795-P2
03/15/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
To renovate existing detached 1 family dwelling.
B00626121-P2
03/01/2023
Permit issued — General Construction
B00626121-I1-GC-CX
01/13/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/07/2022
Violation issued (ECB, closed)
Construction
08/30/2022
Filed — Alteration
B00541795-P1
08/19/2022
Objection resolved — Addressed
08/15/2022
Objection resolved — Addressed
08/12/2022
Objection raised — Zoning
08/12/2022
Objection raised — Zoning
08/08/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
To renovate existing detached 1 family dwelling.
B00626121-P1
07/12/2022
Violation issued (ECB, closed)
Construction
05/27/2022
Permit issued — Plumbing
B00541795-I1-PL
Latest 60 of 83 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCITY PLUMBING INC04/26/2024
DOB NOWFoundationPermit IssuedDIMEX GROUP INC03/11/2024
DOB NOWConstruction FenceSigned-offDIMEX GROUP INC05/21/2023
DOB NOWPlumbingSigned-offCITY PLUMBING INC04/28/2023
DOB NOWGeneral ConstructionPermit IssuedDIMEX GROUP INC03/01/2023
DOB NOWPlumbingSigned-offCITY PLUMBING INC05/27/2022
DOB NOWMechanical SystemsPermit IssuedDIMEX GROUP INC05/25/2022
DOB NOWConstruction FenceSigned-offDIMEX GROUP INC05/19/2022
1 project · most recent 08/01/2024
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/01/2024Permit IssuedDIMEX GROUP INCAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric SEZ-KD09NA4 317 CFM · Ahu ×12
MXZ-4C36NA3 36,400 BTU · Condensing Unit ×3
MXZ-SM48NAM 48,000 BTU · Condensing Unit ×3
PEAD-A30AA7 883 CFM · Ahu ×2
SUZ-KA24NA2 24,000 BTU · Split System ×3
SVZ-KP24NA 735 CFM · Ahu ×3
SeZ-KD18NA4 635 CFM · Vrf Indoor ×2
PEAD-A30AA8 883 CFM · Vrf Indoor ×1
SeZ-KD18NAA 635 CFM · Ahu ×1
York YCG30B21S 27,800 BTU · Condensing Unit ×1
YCG36B21S 34,600 BTU · Condensing Unit ×1
Ventilation
Inline FV-05VQ5 50 CFM · Exhaust Fan ×15
3 projects · most recent 07/12/2024
General Wiring
FiledStatusContractorScope
07/12/2024CompleteSHELBY ELECTRICAL CORPGeneral Wiring
05/25/2022CompleteLENS ELECTRIC, INC—
04/16/2018CancelledNTS ELECTRICAL, INCGeneral Wiring
1 project · most recent 08/01/2024
Steel Wood
FiledStatusContractorScope
08/01/2024Permit IssuedDIMEX GROUP INCSteel, Wood
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
07/25/2024Pass-Final CND-Occupancy InspectionPassView ↗
04/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/18/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/02/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/25/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/13/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 122
DateRequirementInspectorRole
08/13/2024Fenestration and door U-factor and product ratingsJoseph El-kallassyenergy_progress
08/13/2024Air barrier - visual inspectionJoseph El-kallassyenergy_progress
08/13/2024Interior lighting powerJoseph El-kallassyenergy_progress
08/13/2024HVAC-R and service water piping design and insulationJoseph El-kallassyenergy_progress
08/13/2024Fenestration air leakageJoseph El-kallassyenergy_progress
08/13/2024Maintenance informationJoseph El-kallassyenergy_progress
08/13/2024Insulation placement and R valuesJoseph El-kallassyenergy_progress
08/13/2024Fire-Resistance Rated ConstructionJoseph El-kallassyprogress
08/13/2024HVAC-R and service water heating equipmentJoseph El-kallassyenergy_progress
08/13/2024Permanent certificateJoseph El-kallassyenergy_progress
08/13/2024Concrete - Cast-In-PlaceJoseph El-kallassyspecial
08/13/2024Subgrade InspectionsJoseph El-kallassyspecial
08/13/2024FinalJoseph El-kallassyprogress
08/13/2024Energy Code Compliance InspectionsJoseph El-kallassyprogress
08/13/2024Footing and FoundationJoseph El-kallassyprogress
08/13/2024HVAC-R and service water heating system controlsJoseph El-kallassyenergy_progress
08/13/2024Structural Cold-Formed SteelJoseph El-kallassyspecial
08/13/2024Fenestration areasJoseph El-kallassyenergy_progress
08/13/2024Structural Steel - DetailsJoseph El-kallassyspecial
08/13/2024Structural Steel - WeldingJoseph El-kallassyspecial
08/13/2024Mechanical SystemsJoseph El-kallassyspecial
08/13/2024Structural Stability – Alterations of existing buildingsJoseph El-kallassyspecial
08/13/2024Fire-Resistant Penetrations and JointsJoseph El-kallassyspecial
08/13/2024Subsurface Investigations (Borings/Test Pits)Younes Abouyaalaspecial
08/13/2024Structural Steel - High Strength BoltingJoseph El-kallassyspecial
Latest 25 of 122.
▾Documents — 190 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
09/01/2026B00548904-I1Request digital key ↗
09/01/2026B00541795-P3Request digital key ↗
09/01/2026B00541795-P4Request digital key ↗
Showing 3 of 11 on file for this type
▸Zoning, Tax Lot & Property Records11
▸DOB NOWZD1: DOB Zoning Diagram5
08/24/2026B00626121-P2Open ↗
08/15/2026B00626121-P1Open ↗
08/15/2026B00626121-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWZoning Exhibit form (1-5)5
08/24/2026B00626121-P2Open ↗
08/15/2026B00626121-P1Open ↗
08/15/2026B00626121-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00626121-I1Open ↗
▸Seals & Professional Certifications132
▸DOB NOWProgress Inspector Seal & Signature80
09/29/2026B00541795-P3Open ↗
09/29/2026B00541795-P3Open ↗
09/29/2026B00541795-P3Open ↗
Showing 3 of 80 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature41
09/29/2026B00541795-P3Open ↗
09/02/2026B00626121-P4Open ↗
09/02/2026B00626121-P4Open ↗
Showing 3 of 41 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
09/01/2026B00548904-I1Open ↗
09/01/2026B00541795-P3Open ↗
09/01/2026B00541795-P2Open ↗
Showing 3 of 11 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00626121-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
09/01/2026B00541795-P2Open ↗
09/01/2026B00541795-P3Open ↗
09/01/2026B00541795-P4Open ↗
Showing 3 of 10 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00541795-I1Open ↗
08/13/2026B00626121-I1Open ↗
▸Inspections & Test Reports7
▸DOB NOWSOIL REPORT5
08/24/2026B00626121-P2Open ↗
08/15/2026B00626121-P1Open ↗
08/15/2026B00626121-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00626121-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00626121-I1Open ↗
▸Other Documents16
▸DOB NOWSite Survey: Initial5
08/24/2026B00626121-P2Open ↗
08/15/2026B00626121-I1Open ↗
08/15/2026B00626121-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/24/2026B00626121-P2Open ↗
08/15/2026B00626121-I1Open ↗
08/15/2026B00626121-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification5
08/24/2026B00626121-P2Open ↗
08/15/2026B00626121-P1Open ↗
08/15/2026B00626121-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWFinal Survey1
08/13/2026B00626121-I1Open ↗