← Back
Three families
821 QUINCY STREET
BROOKLYN · BIN 3044443
💬 Discuss this project
1899Year Built
3Stories
C0Building Class
R6BZoning
3,300 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · Owner of record: SHALOM EQUITIES LTD · 2,000 sf lot · 1.65 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 31p · 1 filing · 20 docs
Floor 2
Floor 1
Cellar2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GREENBROOK PARTNERS804/09/2026
SHALOM EQUITIES LTD103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/17/2025$1.8M—— → —$536/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RIMKUS NEW YORK PLLC212/09/2025
COMMERCIAL CONSTRUCTION CONSULTING212/08/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EAST COAST EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NTF MANAGEMENT INCGeneral Contractor404/09/2026
P.S.I. MECHANICALPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RIMKUS NEW YORK, PLLC9809212/09/2025
RIMKUS NEW YORK, PLLC8123112/08/2025
Building Lifecycle
All (52)Filed (4)Permit Issued (3)Violation (18)Inspection (5)Special Inspection (22)
01/31/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/14/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/15/2025
Permit issued — General Construction
B01326515-I1-GC
12/10/2025
Permit issued — Mechanical Systems
B01326515-S1-MS
12/10/2025
Permit issued — Plumbing
B01326515-S2-PL
12/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
xueyan zheng
12/10/2025
Special inspection requirement — Final
xueyan zheng
12/10/2025
Special inspection requirement — Energy Code Compliance Inspections
xueyan zheng
12/10/2025
Special inspection requirement — Fire-Resistance Rated Construction
xueyan zheng
12/10/2025
Special inspection requirement — Interior lighting power
xueyan zheng
12/09/2025
Filed — Alteration
General construction associated with renovations to existing three family building. No change in occupancy, use or egress.
B01326515-P1
12/09/2025
Special inspection requirement — Energy Code Compliance Inspections
xueyan zheng
12/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
xueyan zheng
12/09/2025
Special inspection requirement — Final
xueyan zheng
12/09/2025
Special inspection requirement — Fire-Resistance Rated Construction
xueyan zheng
12/09/2025
Special inspection requirement — Interior lighting power
xueyan zheng
12/08/2025
Filed — Alteration
General construction associated with renovations to existing three family building. No change in occupancy, use or egress.
B01326515-I1
12/08/2025
Filed — Alteration
General construction associated with renovations to existing three family building. No change in occupancy, use or egress.
B01326515-S2
12/08/2025
Filed — Alteration
General construction associated with renovations to existing three family building. No change in occupancy, use or egress.
B01326515-S1
12/03/2025
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
12/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Kenneth Wagner
12/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
12/03/2025
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
12/03/2025
Special inspection requirement — Maintenance information
Kenneth Wagner
12/01/2025
Special inspection requirement — HVAC-R and service water heating equipment
Kenneth Wagner
12/01/2025
Special inspection requirement — Final
Kenneth Wagner
12/01/2025
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Wagner
12/01/2025
Special inspection requirement — Ventilation and air distribution system
Kenneth Wagner
12/01/2025
Special inspection requirement — Maintenance information
Kenneth Wagner
12/01/2025
Special inspection requirement — HVAC-R and service water heating system controls
Kenneth Wagner
12/01/2025
Special inspection requirement — Mechanical Systems
Kenneth Wagner
11/20/2025
Violation issued (HPD, closed)
I
09/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/10/2025
Violation issued (HPD, closed)
A
11/27/2024
Violation issued (HPD, closed)
I
04/11/2024
Violation issued (HPD, closed)
A
11/21/2023
Violation issued (HPD, closed)
I
03/24/2023
Violation issued (HPD, closed)
A
11/10/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
A
03/01/2022
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
A
10/31/2019
Violation issued (HPD, closed)
I
10/19/2018
Violation issued (HPD, closed)
I
11/28/2017
Violation issued (HPD, closed)
I
05/15/2017
Violation issued (HPD, closed)
A
11/14/2016
Violation issued (HPD, closed)
I
10/13/2015
Violation issued (HPD, closed)
I
02/24/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNTF MANAGEMENT INC12/15/2025
DOB NOWMechanical SystemsSigned-offNTF MANAGEMENT INC12/10/2025
DOB NOWPlumbingSigned-offP.S.I. MECHANICAL12/10/2025
1 project · most recent 12/09/2025
Heating Systems Others Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/09/2025Signed-offNTF MANAGEMENT INCHeating Systems, Others, Ventilation Systems
Heating
Stelpro Stelpro AB0758W 750 kW · Electric Heater ×19
Stelpro Model #AB61508W 1,500 kW · Electric Heater ×9
Stelpro AB0508W 500 kW · Electric Heater ×5
Stelpro ASS01502T2TW 1,500 kW · Electric Heater ×1
Ventilation
Panasonic Panasonic Model FV-0511VF1 50 CFM · Exhaust Fan ×8
Other
Panasonic (3) Panasonic Model #FV-10VEC2RH 100 kW · Erv ×3
1 project · most recent 12/09/2025
Water/Sanitary
FiledStatusContractorScope
12/09/2025Signed-offP.S.I. MECHANICALWater/Sanitary
2 projects · most recent 08/14/2026
General Wiring
FiledStatusContractorScope
08/14/2026CompleteKJK ELECTRIC INCGeneral Wiring
12/11/2025CompleteKJK ELECTRIC INC—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/31/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/30/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/30/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/14/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
12/10/2025Fire-Resistant Penetrations and Jointsxueyan zhengspecial
12/10/2025Finalxueyan zhengprogress
12/10/2025Energy Code Compliance Inspectionsxueyan zhengprogress
12/10/2025Fire-Resistance Rated Constructionxueyan zhengprogress
12/10/2025Interior lighting powerxueyan zhengenergy_progress
12/09/2025Energy Code Compliance Inspectionsxueyan zhengprogress
12/09/2025Fire-Resistant Penetrations and Jointsxueyan zhengspecial
12/09/2025Finalxueyan zhengprogress
12/09/2025Fire-Resistance Rated Constructionxueyan zhengprogress
12/09/2025Interior lighting powerxueyan zhengenergy_progress
12/03/2025Energy Code Compliance InspectionsKenneth Wagnerprogress
12/03/2025HVAC-R and service water piping design and insulationKenneth Wagnerenergy_progress
12/03/2025HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
12/03/2025HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
12/03/2025Maintenance informationKenneth Wagnerenergy_progress
12/01/2025HVAC-R and service water heating equipmentKenneth Wagnerenergy_progress
12/01/2025FinalKenneth Wagnerprogress
12/01/2025Energy Code Compliance InspectionsKenneth Wagnerprogress
12/01/2025Ventilation and air distribution systemKenneth Wagnerenergy_progress
12/01/2025Maintenance informationKenneth Wagnerenergy_progress
12/01/2025HVAC-R and service water heating system controlsKenneth Wagnerenergy_progress
12/01/2025Mechanical SystemsKenneth Wagnerspecial
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/19/2026B01326515-S2Request digital key ↗
08/19/2026B01326515-P1Request digital key ↗
08/19/2026B01326515-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature19
09/25/2026B01326515-S2Open ↗
09/25/2026B01326515-S2Open ↗
09/25/2026B01326515-S2Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/19/2026B01326515-S1Open ↗
08/19/2026B01326515-S2Open ↗
08/19/2026B01326515-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01326515-S1Open ↗
08/26/2026B01326515-P1Open ↗
08/24/2026B01326515-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/19/2026B01326515-S1Open ↗
08/19/2026B01326515-S2Open ↗
08/19/2026B01326515-P1Open ↗
Showing 3 of 4 on file for this type