← Back
Single or multiple dwelling with stores or offices
823 60 STREET
BROOKLYN · BIN 3140887
💬 Discuss this project
1920Year Built
3Stories
S9Building Class
R6Zoning
—Gross Floor Area
7Units
2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: 5922 TRACY REALTY INC · 2.12 FAR built · Flood zone X
Locations of Work
Mechanical
Permit Issued — active, not yet Signed-off
Floor 3Under Construction4p · 1 filing · 6 docs
Floor 2Under Construction4p · 1 filing · 6 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
5922 TRACY REALTY1403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
UPC ENGINEERING DPC107/31/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KW DEVELOPMENT CONTRACTINGeneral Contractor108/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UPC ENGINEERING D.P.C.1728107/31/2026
Building Lifecycle
All (21)Filed (1)Permit Issued (1)Violation (11)Special Inspection (8)
08/07/2026
Permit issued — Mechanical Systems
B01437034-I1-MS
07/31/2026
Filed — Alteration
PROPOSED TO INSTALL MINI-SPLIT SYSTEM AND ELEC SPACE HEATERS FOR DWELLING UNITS AS PER PLAN. NO CHANGE IN EGRESS, USE AND OCCUPANCY UNDER THIS APPLICATION.
B01437034-I1
07/28/2026
Special inspection requirement — HVAC-R and service water heating system controls
CHUCK CHARK-YUEN YUNG
07/28/2026
Special inspection requirement — Tenant Protection Plan Compliance
CHUCK CHARK-YUEN YUNG
07/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHUCK CHARK-YUEN YUNG
07/28/2026
Special inspection requirement — HVAC-R and service water heating equipment
CHUCK CHARK-YUEN YUNG
07/28/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CHUCK CHARK-YUEN YUNG
07/28/2026
Special inspection requirement — Energy Code Compliance Inspections
CHUCK CHARK-YUEN YUNG
07/27/2026
Special inspection requirement — Final
CHUCK CHARK-YUEN YUNG
07/27/2026
Special inspection requirement — Mechanical Systems
CHUCK CHARK-YUEN YUNG
07/17/2026
Violation issued (ECB, open)
Construction
07/18/2024
Violation issued (ECB, open)
Construction
03/20/2023
Violation issued (HPD, closed)
A
02/22/2022
Violation issued (HPD, closed)
A
04/06/2021
Violation issued (HPD, closed)
A
10/29/2019
Violation issued (HPD, closed)
I
11/16/2017
Violation issued (HPD, closed)
I
10/07/2015
Violation issued (HPD, closed)
I
02/06/2015
Violation issued (HPD, closed)
I
12/15/2010
Violation issued (HPD, closed)
B
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedKW DEVELOPMENT CONTRACTIN08/07/2026
BIS—ISSUEDSIN KAI ENTERPRISES INC04/13/2009
BISPLISSUEDLI SHING LAM CORP02/15/2006
BISOTISSUEDTAMS CONTR INC02/13/2006
BISPLISSUEDATC PL & MECH05/11/2005
BISEQISSUEDSKC CONST04/26/2005
BIS—ISSUEDSKC CONST04/26/2005
BISOTISSUEDYOUNG FONG CONSTRUCTION INC03/11/2005
1 project · most recent 07/31/2026
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
07/31/2026Permit IssuedKW DEVELOPMENT CONTRACTINHeating Systems
Heating
Gree LIV09HP230V1R32AH 9,000 BTU · Ahu ×8
LIV18HP230V1R32AH 18,000 BTU · Ahu ×4
MUL36HP230V1R32AO 36,000 BTU · Condensing Unit ×4
1 project · most recent 08/07/2026
General Wiring
FiledStatusContractorScope
08/07/2026Permit IssuedKWONG MING ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/28/2026HVAC-R and service water heating system controlsCHUCK CHARK-YUEN YUNGenergy_progress
07/28/2026Tenant Protection Plan ComplianceCHUCK CHARK-YUEN YUNGspecial
07/28/2026Fire-Resistant Penetrations and JointsCHUCK CHARK-YUEN YUNGspecial
07/28/2026HVAC-R and service water heating equipmentCHUCK CHARK-YUEN YUNGenergy_progress
07/28/2026HVAC-R and service water piping design and insulationCHUCK CHARK-YUEN YUNGenergy_progress
07/28/2026Energy Code Compliance InspectionsCHUCK CHARK-YUEN YUNGprogress
07/27/2026FinalCHUCK CHARK-YUEN YUNGprogress
07/27/2026Mechanical SystemsCHUCK CHARK-YUEN YUNGspecial
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026B01437034-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
03/27/2009310193956Open ↗
09/09/2008310193956Open ↗
▸BISWORK PERMIT APPLICATION1
04/14/2009310193956Open ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01437034-I1Open ↗
09/01/2026B01437034-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/09/2008310193956Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026B01437034-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B01437034-I1Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
09/09/2008310193956Open ↗
▸Environmental & Asbestos2
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/09/2008310193956Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/16/2026B01437034-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISSCHEDULE A - OCCUPANCY / USE2
09/09/2008310193956Open ↗
03/27/2009310193956Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/08/2010310193956Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
09/09/2008310193956Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/10/2008310193956Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/09/2008310193956Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
09/09/2008310193956Open ↗