← Back
Two family brick
828A VINCENT AVENUE
BRONX · BIN 2078050
💬 Discuss this project
1975Year Built
3Stories
B1Building Class
R3AZoning
2,652 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two family brick · 2,500 sf lot · 1.06 FAR built · Flood zone X
Locations of Work
Architecture
Cellar4p · 1 filing · 19 docs
Nothing on file for this building.
Building Lifecycle
All (32)Filed (3)Permit Issued (1)Violation (3)Inspection (3)Objection (16)Special Inspection (6)
07/08/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/07/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/07/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/17/2024
Filed — Alteration CO
PROPOSED ALT1 CO FILED TO MAKE CHANGES TO EXISTING 2-FAM FAMILY HOUSE CO TO PROPOSE CELLAR AS ACCESSORY USE TO 1ST FLOOR. NO CHANGE OF USE, GROUP, OR OCCUPANCY IS PROPOSED UNDER THIS APPLICATION.
X00994229-P2
04/17/2024
Special inspection requirement — Energy Code Compliance Inspections
John Alleyne
04/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
John Alleyne
04/17/2024
Special inspection requirement — Interior lighting power
John Alleyne
04/10/2024
Filed — Alteration CO
PROPOSED ALT1 CO FILED TO MAKE CHANGES TO EXISTING 2-FAM FAMILY HOUSE CO TO PROPOSE CELLAR AS ACCESSORY USE TO 1ST FLOOR. NO CHANGE OF USE, GROUP, OR OCCUPANCY IS PROPOSED UNDER THIS APPLICATION.
X00994229-P1
04/08/2024
Special inspection requirement — Energy Code Compliance Inspections
John Alleyne
04/08/2024
Special inspection requirement — Fire-Resistance Rated Construction
John Alleyne
04/08/2024
Special inspection requirement — Interior lighting power
John Alleyne
04/04/2024
Permit issued — General Construction
X00994229-I1-GC
03/22/2024
Objection resolved — Addressed
03/18/2024
Objection raised — Admin
03/18/2024
Objection resolved — Addressed
03/12/2024
Objection raised — Admin
03/12/2024
Objection resolved — Addressed
02/14/2024
Objection raised — Admin
02/14/2024
Objection resolved — Addressed
02/14/2024
Objection resolved — Addressed
02/14/2024
Objection resolved — Addressed
02/14/2024
Objection resolved — Addressed
02/14/2024
Objection resolved — Addressed
02/01/2024
Objection raised — Admin
02/01/2024
Objection raised — Energy
02/01/2024
Objection raised — Admin
02/01/2024
Objection raised — Cost
02/01/2024
Objection raised — Admin
01/25/2024
Filed — Alteration CO
PROPOSED ALT1 CO FILED TO MAKE CHANGES TO EXISTING 2-FAM FAMILY HOUSE CO TO PROPOSE CELLAR AS ACCESSORY USE TO 1ST FLOOR. NO CHANGE OF USE, GROUP, OR OCCUPANCY IS PROPOSED UNDER THIS APPLICATION.
X00994229-I1
05/22/2007
Violation issued (ECB, open)
Construction
09/11/2002
Violation issued (ECB, closed)
Construction
09/24/2001
Violation issued (ECB, closed)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNER OF 828A VINCERT AVE103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/14/2022$830K—Private party → Private party$313/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BECALL ENGINEERING SERVICES INC.304/17/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAMC CONSULTING REPS LLCGeneral Contractor107/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMAMC CONSULTING REPS LLC04/04/2024
BIS—ISSUEDARRIAGA & ASSOC.01/17/2002
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/08/2024Pass-Final CND-Occupancy InspectionPassView ↗
06/07/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/07/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
04/17/2024Energy Code Compliance InspectionsJohn Alleyneprogress
04/17/2024Fire-Resistance Rated ConstructionJohn Alleyneprogress
04/17/2024Interior lighting powerJohn Alleyneenergy_progress
04/08/2024Energy Code Compliance InspectionsJohn Alleyneprogress
04/08/2024Fire-Resistance Rated ConstructionJohn Alleyneprogress
04/08/2024Interior lighting powerJohn Alleyneenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026X00994229-P1Request digital key ↗
08/21/2026X00994229-I1Request digital key ↗
08/21/2026X00994229-P2Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026X00994229-P1Open ↗
09/23/2026X00994229-P1Open ↗
08/25/2026X00994229-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026X00994229-P1Open ↗
08/21/2026X00994229-I1Open ↗
08/21/2026X00994229-P2Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/13/2026X00994229-P2Open ↗
08/13/2026X00994229-I1Open ↗
08/13/2026X00994229-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026X00994229-P1Open ↗
08/21/2026X00994229-I1Open ↗
08/21/2026X00994229-P2Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification3
08/21/2026X00994229-P2Open ↗
08/21/2026X00994229-P1Open ↗
08/21/2026X00994229-I1Open ↗