← Back
Cape Cod
83-14 248 STREET
QUEENS · Bellerose · BIN 4175195
💬 Discuss this project
1950Year Built
1.67Stories
A0Building Class
R2AZoning
1,542 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
Cape Cod · 4,000 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar1p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/14/2023$880K—— → —$571/sf building
01/22/2020$780K—— → —$506/sf building
02/01/2017$495K—HARRAN CH INC. → Private party$321/sf building
11/10/2016$475K—Private party → HARRAN CH INC$308/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARQUITECTURA VARELA306/07/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
5 BORO CONSTRUCTION SERV*General Contractor207/08/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
M & M PIPING AND HEATINGPlumbing107/08/2026
Building Lifecycle
All (17)Filed (3)Permit Issued (4)Signed Off (2)Violation (2)Inspection (5)Special Inspection (1)
10/25/2024
Signed off — Alteration
HEREWITH FILING TO LEGALIZE 3-PC BATHROOM AND CAP & REMOVE WATER & WASTE LINES FOR SINK, REMOVE NON-LOAD BEARING PARTITIONS AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
Q00991461-S1
10/24/2024
Signed off — Alteration
HEREWITH FILING TO LEGALIZE 3-PC BATHROOM AND CAP & REMOVE WATER & WASTE LINES FOR SINK, REMOVE NON-LOAD BEARING PARTITIONS AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
Q00991461-I1
08/23/2024
Violation issued (ECB, closed)
Construction
07/25/2024
Permit issued — Plumbing
Q00991461-I1-PL
07/11/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/07/2024
Filed — Alteration
HEREWITH FILING TO LEGALIZE 3-PC BATHROOM AND CAP & REMOVE WATER & WASTE LINES FOR SINK, REMOVE NON-LOAD BEARING PARTITIONS AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
Q00991461-P1
05/31/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/31/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/23/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/20/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/23/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/03/2024
Permit issued — General Construction
Q00991461-S1-GC
03/01/2024
Permit issued — General Construction
Q00991461-S1-GC
02/28/2024
Permit issued — Plumbing
Q00991461-I1-PL
02/08/2024
Filed — Alteration
HEREWITH FILING TO LEGALIZE 3-PC BATHROOM AND CAP & REMOVE WATER & WASTE LINES FOR SINK, REMOVE NON-LOAD BEARING PARTITIONS AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
Q00991461-S1
02/08/2024
Filed — Alteration
HEREWITH FILING TO LEGALIZE 3-PC BATHROOM AND CAP & REMOVE WATER & WASTE LINES FOR SINK, REMOVE NON-LOAD BEARING PARTITIONS AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
Q00991461-I1
01/17/2024
Special inspection requirement — Final
Vicente Varela
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offM & M PIPING AND HEATING07/25/2024
DOB NOWGeneral ConstructionSigned-off5 BORO CONSTRUCTION SERV*04/03/2024
DOB NOWGeneral ConstructionSigned-off5 BORO CONSTRUCTION SERV*03/01/2024
DOB NOWPlumbingSigned-offHORBRIDGE PLUMBING & HEAT02/28/2024
1 project · most recent 10/18/2024
General Wiring
FiledStatusContractorScope
10/18/2024CompleteWORD OF LIGHT ELECT LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/31/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/31/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/23/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/20/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/23/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
01/17/2024FinalVicente Varelaprogress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026Q00991461-P1Request digital key ↗
08/23/2026Q00991461-S1Request digital key ↗
08/23/2026Q00991461-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026Q00991461-I1Open ↗
08/13/2026Q00991461-P1Open ↗
08/13/2026Q00991461-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026Q00991461-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026Q00991461-I1Open ↗
08/13/2026Q00991461-P1Open ↗
08/13/2026Q00991461-S1Open ↗