← Back
Office with commercial, 1-6 stories
83 3 AVENUE
BROOKLYN · BIN 3001438
💬 Discuss this project
1910Year Built
3Stories
O5Building Class
R7AZoning
14,510 sfGross Floor Area
2Units
0 Open Violations
Office with commercial, 1-6 stories · Owner of record: 83-3RD AVE. CORP · 5,321 sf lot · 2.73 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof1p · 1 filing · 8 docs
Floor 335p · 5 filings · 20 docs
Floor 229p · 5 filings · 20 docs
Floor 128p · 3 filings · 20 docs
Cellar41p · 5 filings · 20 docs
1 job · most recent 08/31/2021
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
08/31/2021Permit IssuedPA BUILDERS, INCAir Conditioning Systems, Heating Systems
Cooling
Daikin FXMQ48PBVJU 45,471 CFM · Vrf Indoor ×24
RXLQ144TATJU 12 tons · Vrf Outdoor ×16
VAM1200GVJU 850 CFM · Erv ×16
FXMQ96MVJU 8 tons · Vrf Indoor ×8
RZQ30TAVJU 2 tons · Vrf Outdoor ×4
Heating
Daikin FXMQ96MVJU 113,996 CFM · Vrf Indoor ×4
1 job · most recent 08/27/2021
FiledStatusContractorScope
08/27/2021Signed-offCASE PLUMBING LLC114 heads
1 job · most recent 08/31/2021
Gas Water/Sanitary
FiledStatusContractorScope
08/31/2021Signed-offVMC PLUMBING & HEATING INGas, Water/Sanitary
5 jobs · most recent 03/04/2022
General Wiring
FiledStatusContractorScope
03/04/2022CompleteFISHER ELECL CONTNG LLCGeneral Wiring
08/16/2021CompleteFSM ELECTRICAL CORPORATIO5 meters, 5 new_meters
04/12/2021CompleteFSM ELECTRICAL CORPORATIOGeneral Wiring
09/15/2020CompleteWCK ELECTRIC CORP.—
08/12/2020CompleteKWONG MING ELECTRIC INC—
Building Lifecycle
All (112)Filed (21)Permit Issued (21)Signed Off (9)Violation (20)Inspection (7)Objection (6)Special Inspection (28)
09/22/2026
Objection resolved — Resolved
09/22/2026
Objection resolved — Resolved
09/22/2026
Objection resolved — Resolved
09/17/2026
Objection raised — Other
09/17/2026
Objection raised — Other
09/17/2026
Objection raised — Other
09/02/2026
Filed — Alteration CO
APPLICATION FILED TO CHANGE USE AT GROUND FLOOR AND CELLAR FROM STORAGE TO RETAIL AND OFFICE USES AS PER PLAN NEW EGRESS STAIR AND OBTAIN NEW CERTIFICATE OF OCCUPANCY HEREWITH. DOB NOW RELATED APPLICATION NUMBERS DEMOLITION: 340726218, STRUCTURAL: B003721
B00557984-P4
05/27/2026
Permit issued — Sprinklers
B00348143-I1-EW-SP
04/20/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/07/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/30/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/26/2025
Permit issued — Plumbing
B00342052-I1-PL
08/15/2025
Signed off — Alteration
B00457080-I1
08/14/2025
Signed off — Alteration
#8465 - Mechanical ductwork modifications. No change in egress, use, or occupancy.
B00457496-I1
08/14/2025
Signed off — Alteration
B00457471-I1
07/21/2025
Filed — Alteration CO
APPLICATION FILED TO CHANGE USE AT GROUND FLOOR AND CELLAR FROM STORAGE TO RETAIL AND OFFICE USES AS PER PLAN NEW EGRESS STAIR AND OBTAIN NEW CERTIFICATE OF OCCUPANCY HEREWITH. DOB NOW RELATED APPLICATION NUMBERS DEMOLITION: 340726218, STRUCTURAL: B003721
B00557984-P3
04/18/2025
Signed off — Alteration
B00379427-I1
11/22/2023
Signed off — Alteration
APPLICATION FILED FOR INTERIOR RENOVATION OF EXISTING SPACE @ 2ND FLOOR AS PER PLANS . NO CHANGE IN USE OCCUPANCY OR EGRESS.
B00816255-I1
11/21/2023
Permit issued — Mechanical Systems
B00457496-I1-MS
07/10/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/27/2023
Filed — No Work
B00895645-I1
05/18/2023
Signed off — Alteration
INSTALL EXTERIOR NON-ILLUMINATED BLADE SIGN (JEREMIAH PROGRAM BROOKLYN)
B00860640-I1
05/01/2023
Permit issued — Sign
B00860640-I1-SG
04/28/2023
Filed — Alteration
INSTALL EXTERIOR NON-ILLUMINATED BLADE SIGN (JEREMIAH PROGRAM BROOKLYN)
B00860640-I1
04/25/2023
Signed off — Alteration
INSTALL EXTERIOR NON-ILLUMINATED BLADE SIGN (LIFESTANCE HEALTH)
B00847523-I1
04/17/2023
Special inspection requirement — Final
LEON SKVIRSKY
04/14/2023
Permit issued — Sign
B00847523-I1-SG
04/12/2023
Filed — Alteration
INSTALL EXTERIOR NON-ILLUMINATED BLADE SIGN (LIFESTANCE HEALTH)
B00847523-I1
03/21/2023
Special inspection requirement — Final
LEON SKVIRSKY
03/02/2023
Permit issued — General Construction
B00816255-I1-GC
01/27/2023
Permit issued — General Construction
B00816255-I1-GC
01/22/2023
Filed — Alteration
APPLICATION FILED FOR INTERIOR RENOVATION OF EXISTING SPACE @ 2ND FLOOR AS PER PLANS . NO CHANGE IN USE OCCUPANCY OR EGRESS.
B00816255-I1
08/25/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/15/2022
Signed off — Alteration
B00687770-I1
03/17/2022
Permit issued — Sign
B00687770-I1-SG
03/14/2022
Filed — Alteration
B00687770-I1
03/04/2022
Signed off — Alteration
ABANDON EXISTING FUEL STORAGE TANK AS PER PLANS. (EXISTING BOILER & BURNER HAVE BEEN REMOVED UNDER LAA# B00399919-I1) NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00679101-I1
03/02/2022
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
02/25/2022
Special inspection requirement — Final
LEON SKVIRSKY
02/24/2022
Permit issued — Boiler Equipment
B00679101-I1-BE
02/23/2022
Filed — Alteration
ABANDON EXISTING FUEL STORAGE TANK AS PER PLANS. (EXISTING BOILER & BURNER HAVE BEEN REMOVED UNDER LAA# B00399919-I1) NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00679101-I1
02/23/2022
Special inspection requirement — Fuel-Oil Storage and Fuel-Oil Piping Systems
Stephen Shishko
11/16/2021
Permit issued — Mechanical Systems
B00341972-I1-MS
10/05/2021
Permit issued — Sprinklers
B00348143-I1-EW-SP
09/22/2021
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/21/2021
Permit issued — Plumbing
B00342052-I1-PL
09/10/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ronald Merhige
09/10/2021
Special inspection requirement — HVAC insulation and sealing
Ronald Merhige
09/10/2021
Special inspection requirement — HVAC and service water heating equipment
Ronald Merhige
09/10/2021
Special inspection requirement — HVAC and service water heating system controls
Ronald Merhige
09/09/2021
Special inspection requirement — Maintenance information
Hackjong Choi
09/09/2021
Special inspection requirement — HVAC and service water heating system controls
Hackjong Choi
09/09/2021
Special inspection requirement — HVAC and service water heating equipment
Hackjong Choi
09/09/2021
Special inspection requirement — HVAC insulation and sealing
Hackjong Choi
09/09/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hackjong Choi
09/09/2021
Special inspection requirement — Mechanical Systems
Hackjong Choi
09/09/2021
Special inspection requirement — Final
Hackjong Choi
08/31/2021
Filed — Alteration
APPLICATION FILED FOR MECHANICAL WORK AND ASSOCIATED DUCT-WORK AND PIPING IN CONJUNCTION WITH ALT 2 DOB FILING. NO CHANGE IN USE OCCUPANCY OR EGRESS
B00341972-P1
Latest 60 of 112 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ABINGDON SQUARE PARTNERS909/20/2026
ASP4007/08/2026
GUL & G CONTRACTING INC503/22/2026
83 3 AVE503/22/2026
BUYK103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOHN SARACCO ARCHITECT LLC509/02/2026
LEON SKVIRSKY PE304/28/2023
NEW AGE ENGINEERING PLLC102/23/2022
RLM ENGINEERING PLLC708/31/2021
BLUE STREAK CONSULTING201/27/2021
ONYX CREATIVE101/27/2021
ASHRAF CORP108/03/2020
STRATFORD ENGINEERING107/21/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILDING BROTHERS603/21/2026
TAG TEAM GROUP LLC2403/21/2026
PEROTTO CONSULTING MANAGEMENT603/21/2026
DANICO SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PA BUILDERS, INCGeneral Contractor2607/08/2026
PAUL SIGNSScaffold307/08/2026
GUL & G CONTRACTING INCGeneral Contractor303/21/2026
VILLAGE P & H NY INCFire Protection207/08/2026
L&J PLG & HTG CO OF NY INPlumbing207/08/2026
FSM ELECTRICAL CORPORATIOElectrical103/22/2026
VMC PLUMBING & HEATING INPlumbing107/08/2026
CASE PLUMBING LLCFire Protection107/04/2026
ALL HOUR SEWER SERVICE CO.Plumbing107/08/2026
FISHER ELECL CONTNG LLCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746102/23/2022
BEYOND ARCH LLC3600208/31/2021
RLM ENGINEERING PLLC6913508/31/2021
AK ENGINEERING PC678201/27/2021
STRATFORD ENGINEERING997107/21/2020
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offCASE PLUMBING LLC05/27/2026
DOB NOWPlumbingSigned-offM. SPINELLI PLB & HTG INC08/26/2025
DOB NOWMechanical SystemsSigned-offPA BUILDERS, INC11/21/2023
DOB NOWSignSigned-offPAUL SIGNS, INC05/01/2023
DOB NOWSignSigned-offPAUL SIGNS, INC04/14/2023
DOB NOWGeneral ConstructionSigned-offPA BUILDERS, INC03/02/2023
DOB NOWGeneral ConstructionSigned-offPA BUILDERS, INC01/27/2023
DOB NOWSignSigned-offPAUL SIGNS, INC03/17/2022
DOB NOWBoiler EquipmentSigned-offNEW YORK HEATING CORP02/24/2022
DOB NOWMechanical SystemsPermit IssuedPA BUILDERS, INC11/16/2021
DOB NOWSprinklersSigned-offVILLAGE P & H NY INC10/05/2021
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN09/21/2021
DOB NOWGeneral ConstructionPermit IssuedPA BUILDERS, INC08/27/2021
DOB NOWStructuralPermit IssuedPA BUILDERS, INC07/28/2021
DOB NOWGeneral ConstructionSigned-offPA BUILDERS, INC02/27/2021
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN02/16/2021
DOB NOWGeneral ConstructionSigned-offPA BUILDERS, INC02/01/2021
DOB NOWMechanical SystemsSigned-offPA BUILDERS, INC01/28/2021
DOB NOWSprinklersSigned-offVILLAGE P & H NY INC12/15/2020
DOB NOWPlumbingSigned-offALL HOUR SEWER SERVICE CO.11/23/2020
DOB NOWSidewalk ShedSigned-offGUL & G CONTRACTING INC08/05/2020
BISOTISSUEDPA BUILDERS, INC03/09/2021
BISOTISSUEDPA BUILDERS, INC11/18/2020
BISOTISSUEDPA BUILDERS, INC10/21/2020
BISEQISSUEDROCKLEDGE SCAFFOLD CORP12/29/2005
BISEQISSUEDROCKLEDGE SCAFFOLD CORP12/23/2005
BISEQISSUEDROCKLEDGE SCAFFOLD CORP07/21/2005
BISEQISSUEDROCKLEDGE SCAFFOLD CORP07/08/2005
BISEQISSUEDROCKLEDGE SCAFFOLD CORP07/08/2005
BISFBISSUEDN Y HEATING CORP09/11/2003
BISFSISSUEDVIJAX FUEL CORP.05/02/1994
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
04/20/2026Pass-Final CND-Occupancy InspectionPassView ↗
11/07/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/30/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/10/2023Pass-Final CND-Occupancy InspectionPassView ↗
08/25/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/02/2022Pass-Final Boiler Equipment InspectionPassView ↗
09/22/2021Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
04/17/2023FinalLEON SKVIRSKYprogress
03/21/2023FinalLEON SKVIRSKYprogress
02/25/2022FinalLEON SKVIRSKYprogress
02/23/2022Fuel-Oil Storage and Fuel-Oil Piping SystemsStephen Shishkospecial
09/10/2021Fire-Resistant Penetrations and JointsRonald Merhigespecial
09/10/2021HVAC insulation and sealing Ronald Merhigeenergy_progress
09/10/2021HVAC and service water heating equipment Ronald Merhigeenergy_progress
09/10/2021HVAC and service water heating system controls Ronald Merhigeenergy_progress
09/09/2021Maintenance informationHackjong Choienergy_progress
09/09/2021HVAC and service water heating system controls Hackjong Choienergy_progress
09/09/2021HVAC and service water heating equipment Hackjong Choienergy_progress
09/09/2021HVAC insulation and sealing Hackjong Choienergy_progress
09/09/2021Fire-Resistant Penetrations and JointsHackjong Choispecial
09/09/2021Mechanical SystemsHackjong Choispecial
09/09/2021FinalHackjong Choiprogress
08/30/2021HVAC and service water heating equipment Ronald Merhigeenergy_progress
08/30/2021Fire-Resistant Penetrations and JointsRonald Merhigespecial
08/30/2021HVAC insulation and sealing Ronald Merhigeenergy_progress
08/30/2021HVAC and service water heating system controls Ronald Merhigeenergy_progress
08/24/2021HVAC and service water heating equipment Ronald Merhigeenergy_progress
08/24/2021HVAC and service water heating system controls Ronald Merhigeenergy_progress
08/24/2021HVAC insulation and sealing Ronald Merhigeenergy_progress
08/24/2021Fire-Resistant Penetrations and JointsRonald Merhigespecial
08/11/2021Fire-Resistant Penetrations and JointsRonald Merhigespecial
08/11/2021Sprinkler SystemsRonald Merhigespecial
Latest 25 of 28.
▾Documents — 156 on file (BIS + DOB NOW)
▸Plans & Drawings20
▸DOB NOWPlans/Sketch7
09/01/2026B00557984-P4Request digital key ↗
08/31/2026B00679101-I1Request digital key ↗
08/31/2026B00687770-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸DOB NOWPlans/Sketch - Plumbing4
09/01/2026B00457471-I1Request digital key ↗
09/01/2026B00342052-I1Request digital key ↗
08/15/2026B00342052-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems3
09/01/2026B00457496-I1Request digital key ↗
09/01/2026B00341972-I1Request digital key ↗
08/15/2026B00341972-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler2
09/02/2026B00348143-I1Request digital key ↗
08/15/2026B00348143-P1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
09/01/2026B00457080-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Temporary Place of Assembly1
08/27/2026B00895645-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00379427-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
09/02/2026B00372193-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION7
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
06/30/2020340726806Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION2
11/18/2020340786714Open ↗
10/21/2020340726218Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/21/2026B00557984-I1Open ↗
08/13/2026B00557984-I1Open ↗
▸Seals & Professional Certifications57
▸DOB NOWDPL-1: Design Professional Seal & Signature20
09/01/2026B00457471-I1Open ↗
09/01/2026B00457496-I1Open ↗
09/01/2026B00457080-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWProgress Inspector Seal & Signature18
09/01/2026B00342052-P2Open ↗
09/01/2026B00342052-P2Open ↗
09/01/2026B00342052-P2Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/23/2026B00679101-I1Open ↗
09/01/2026B00342052-P2Open ↗
09/01/2026B00341972-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
05/01/2020340726218Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
05/01/2020340726218Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
05/01/2020340726218Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
05/04/2020340726806Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
09/01/2026B00557984-P4Open ↗
08/21/2026B00557984-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00557984-I1Open ↗
▸Environmental & Asbestos20
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
09/01/2026B00457471-I1Open ↗
09/01/2026B00457496-I1Open ↗
09/01/2026B00457080-I1Open ↗
Showing 3 of 17 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
11/13/2020340786714Open ↗
09/03/2020340726806Open ↗
05/01/2020340726218Open ↗
▸Energy Compliance16
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
11/18/2020340786714Open ↗
11/13/2020340786714Open ↗
09/10/2020340726218Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
05/01/2020340726218Open ↗
▸DOB NOWEN2: As Built Energy Analysis.3
09/01/2026B00457496-I1Open ↗
08/13/2026B00457080-I1Open ↗
08/13/2026B00457471-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
01/18/2024340786714Open ↗
01/18/2024340726218Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS2
01/18/2024340786714Open ↗
01/18/2024340726218Open ↗
▸BISLIGHTING CONTROLS1
01/18/2024340786714Open ↗
▸BISINTERIOR LIGHTING POWER1
01/18/2024340786714Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: RESPONSIBILITY6
11/18/2020340786714Open ↗
11/13/2020340786714Open ↗
09/10/2020340726218Open ↗
Showing 3 of 6 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)2
01/18/2024340786714Open ↗
01/18/2024340726218Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
01/18/2024340726218Open ↗
▸Approvals, Objections & Sign-offs3
▸BISFINAL2
01/18/2024340786714Open ↗
01/18/2024340726218Open ↗
▸BISSCHEDULE A - OCCUPANCY - USE1
12/02/2020340784379Open ↗
▸Cost, Insurance & Ownership8
▸BISCOST AFFIDAVIT6
02/08/2024340786714Open ↗
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
Showing 3 of 6 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
02/08/2024340726218Open ↗
02/08/2024340786714Open ↗
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION5
09/14/2020340726806Open ↗
08/25/2020340726806Open ↗
08/10/2020340726806Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
11/13/2020340786714Open ↗
11/13/2020340784379Open ↗
05/04/2020340726806Open ↗
Showing 3 of 4 on file for this type