← Back
BuildNYC
Two family brick
830 PRESIDENT STREET
BROOKLYN · Park Slope · BIN 3024738
💬 Discuss this project
1887Year Built
3Stories
B1Building Class
R7BZoning
4,336 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family brick · 2,033 sf lot · 2.13 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof12p · 3 filings · 20 docs
Floor 311p · 2 filings · 17 docs
Floor 212p · 3 filings · 20 docs
Floor 111p · 2 filings · 17 docs
Cellar13p · 3 filings · 20 docs
Sub-Basement11p · 2 filings · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/09/2021$4.3M—MELVIN E. BRENDER, A.3 U/W OF THERESA A. LAWLER → Private party$992/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Raad207/11/2022
Rebuild Architecture105/16/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
The Vilnits Group203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Rebuild WorkshopGeneral Contractor707/08/2026
John Hlad P & H CoPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Raad7727207/11/2022
HPL Engineering5613105/16/2022
Building Lifecycle
12/29/2023
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B00737150-I1-GC-CX
11/20/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/22/2023
Permit expired, never signed off — Mechanical Systems
The city's record still shows this permit as issued, with no sign-off on its filing
B00747511-I1-MS
06/16/2023
Permit renewed — Plumbing
Renewed without changes
B00747501-I1-PL
03/03/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
32 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJohn Hlad P & H Co06/16/2023
DOB NOWGeneral ConstructionPermit IssuedRebuild Workshop12/29/2022
DOB NOWStructuralPermit IssuedRebuild Workshop09/24/2022
DOB NOWMechanical SystemsPermit IssuedRebuild Workshop07/22/2022
DOB NOWPlumbingSigned-offJohn Hlad P & H Co07/16/2022
1 project · most recent 07/11/2022
Gas Water/Sanitary
FiledStatusContractorScope
07/11/2022Signed-offJohn Hlad P & H CoGas, Water/Sanitary
1 project · most recent 03/04/2024
General Wiring
FiledStatusContractorScope
03/04/2024CompleteJun Safety ElectricalGeneral Wiring
1 project · most recent 05/16/2022
Steel Concrete
FiledStatusContractorScope
05/16/2022Permit IssuedRebuild WorkshopSteel, Concrete
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/03/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/01/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
08/16/2022Concrete - Cast-In-PlaceFran Huangspecial
08/16/2022Fire-Resistance Rated ConstructionFran Huangprogress
08/16/2022Fire-Resistant Penetrations and JointsFran Huangspecial
05/27/2022Fire-Resistant Penetrations and JointsNICHOLAS AZADIANspecial
05/16/2022Structural Steel - DetailsFran Huangspecial
05/16/2022Structural Cold-Formed SteelFran Huangspecial
05/12/2022Structural Stability – Alterations of existing buildingsFran Huangspecial
05/12/2022FinalFran Huangprogress
21 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account