← Back
Three families
831 PRESIDENT STREET
BROOKLYN · Park Slope · BIN 3024675
💬 Discuss this project
1899Year Built
4Stories
C0Building Class
R6AZoning
6,300 sfGross Floor Area
3Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Three families · Owner of record: 831 PRESIDENT STREET LLC · 1,995 sf lot · 3.16 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction13p · 1 filing · 20 docs
Floor 3Under Construction15p · 1 filing · 20 docs
Floor 2Under Construction15p · 1 filing · 20 docs
Floor 1Under Construction22p · 1 filing · 20 docs
CellarUnder Construction18p · 1 filing · 20 docs
BasementUnder Construction19p · 1 filing · 20 docs
Sub-BasementUnder Construction4p · 1 filing · 20 docs
Site & exteriorUnder Construction4p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COPPERMINE CONSTRUCTION407/08/2026
831 PRESIDENT STREET LLC103/22/2026
DK GENERAL CONTRACTOR103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/25/2025$3.9M—Private party → 831 PRESIDENT STREET LLC$611/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DOMANI CONSULTING503/21/2026
CASA GROUP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
COPPERMINE CONSTRUCTION *General Contractor307/08/2026
CALLAHAN CONTRACTING LLCGeneral Contractor107/08/2026
RITE WAY HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GRAND MILLENNIUM CONSULTI469107/21/2026
KIMBERLY PECK ARCHITECT,6812407/02/2026
SHAHRISH SHUVO ENGINEERIN8524101/14/2026
ARCO ENGINEERING PC3769111/16/2025
Building Lifecycle
All (130)Filed (9)Permit Issued (5)Violation (7)Inspection (1)Objection (78)Special Inspection (30)
08/18/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/04/2026
Objection resolved — Resolved
08/04/2026
Objection resolved — Resolved
08/04/2026
Objection resolved — Resolved
07/31/2026
Objection raised — Structural
07/31/2026
Objection raised — Admin
07/31/2026
Objection raised — Admin
07/21/2026
Filed — Alteration CO
Herewith file plans for plumbing work on floors cellar, basement, 1,2,3 of proposed two family dwelling (filed in conjunction with GC application)
B01286906-S8
07/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
kimberly peck
07/16/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
kimberly peck
07/14/2026
Objection resolved — Addressed
07/14/2026
Objection resolved — Addressed
07/14/2026
Objection resolved — Resolved
07/08/2026
Objection raised — Other
07/08/2026
Objection raised — Other
07/02/2026
Filed — Alteration CO
Herewith file plans for plumbing work on floors cellar, basement, 1,2,3 of proposed two family dwelling (filed in conjunction with GC application)
B01286906-P2
06/04/2026
Objection resolved — Addressed
05/09/2026
Objection resolved — Addressed
05/06/2026
Objection resolved — Addressed
05/06/2026
Objection resolved — Addressed
05/06/2026
Objection resolved — Addressed
05/06/2026
Objection resolved — Addressed
05/06/2026
Objection resolved — Addressed
05/05/2026
Violation issued (HPD, open)
A
04/27/2026
Objection resolved — Addressed
04/25/2026
Objection resolved — Addressed
04/25/2026
Objection resolved — Addressed
04/23/2026
Objection resolved — Addressed
04/22/2026
Objection raised — Scope
04/22/2026
Objection raised — Fire_Protection
04/22/2026
Objection raised — Scope
04/22/2026
Objection raised — Scope
04/22/2026
Objection raised — Fire_Protection
04/22/2026
Objection raised — Scope
04/22/2026
Objection raised — Fire_Protection
04/22/2026
Objection raised — Scope
04/22/2026
Objection raised — Fire_Protection
04/20/2026
Objection raised — Scope
04/20/2026
Objection raised — Scope
04/10/2026
Filed — Alteration CO
Herewith file plans for plumbing work on floors cellar, basement, 1,2,3 of proposed two family dwelling (filed in conjunction with GC application)
B01286906-P3
03/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
kimberly peck
03/20/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
kimberly peck
03/20/2026
Special inspection requirement — Insulation placement and R values
kimberly peck
03/20/2026
Special inspection requirement — Fenestration air leakage
kimberly peck
03/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
kimberly peck
03/20/2026
Special inspection requirement — Air barrier - visual inspection
kimberly peck
03/20/2026
Special inspection requirement — Lighting in dwelling units
kimberly peck
02/27/2026
Permit issued — Plumbing
B01286906-S1-PL
02/17/2026
Permit issued — Construction Fence
B01358154-I1-FN
02/16/2026
Filed — Alteration
B01358154-I1
02/16/2026
Special inspection requirement — Shutoff dampers
Michael McSweeney
02/13/2026
Permit issued — General Construction
B01286906-I1-GC
02/13/2026
Permit issued — Structural
B01286906-S5-ST
02/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
kimberly peck
02/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
kimberly peck
02/04/2026
Permit issued — General Construction
B01286906-I1-GC
01/30/2026
Objection resolved — Addressed
01/30/2026
Objection resolved — Addressed
01/30/2026
Objection resolved — Addressed
01/30/2026
Objection resolved — Addressed
Latest 60 of 130 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedLS PLUMBING CORP02/27/2026
DOB NOWConstruction FencePermit IssuedCOPPERMINE CONSTRUCTION *02/17/2026
DOB NOWGeneral ConstructionPermit IssuedCOPPERMINE CONSTRUCTION *02/13/2026
DOB NOWStructuralPermit IssuedCOPPERMINE CONSTRUCTION *02/13/2026
DOB NOWGeneral ConstructionPermit IssuedCALLAHAN CONTRACTING LLC02/04/2026
BISEQISSUEDACUMATE SERVICES, LLC09/23/2016
1 project · most recent 07/21/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/21/2026Permit IssuedCOPPERMINE CONSTRUCTION *Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NL 48,000 BTU · Condensing Unit ×2
1 project · most recent 07/21/2026
Sprinkler System
FiledStatusContractorScope
07/21/2026——Sprinkler System
1 project · most recent 07/21/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/21/2026Permit IssuedRITE WAY HEATING CORPGas, Water/Sanitary
1 project · most recent 04/17/2026
General Wiring
FiledStatusContractorScope
04/17/2026Permit IssuedKEPLER ELECTRICAL CONTGeneral Wiring
1 project · most recent 07/21/2026
Steel Concrete Masonry Wood
FiledStatusContractorScope
07/21/2026Permit IssuedRITE WAY HEATING CORPSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/18/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
07/16/2026Fire-Resistant Penetrations and Jointskimberly peckspecial
07/16/2026HVAC-R and service water piping design and insulationkimberly peckenergy_progress
03/20/2026Fire-Resistant Penetrations and Jointskimberly peckspecial
03/20/2026Fenestration and door U-factor and product ratingskimberly peckenergy_progress
03/20/2026Insulation placement and R valueskimberly peckenergy_progress
03/20/2026Fenestration air leakagekimberly peckenergy_progress
03/20/2026Fire-Resistance Rated Constructionkimberly peckprogress
03/20/2026Air barrier - visual inspectionkimberly peckenergy_progress
03/20/2026Lighting in dwelling unitskimberly peckenergy_progress
02/16/2026Shutoff dampersMichael McSweeneyenergy_progress
02/09/2026HVAC-R and service water piping design and insulationkimberly peckenergy_progress
02/09/2026Fire-Resistant Penetrations and Jointskimberly peckspecial
01/09/2026MasonryShahrish Shuvospecial
01/09/2026Concrete - Cast-In-PlaceShahrish Shuvospecial
01/09/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
01/09/2026Structural Steel - DetailsShahrish Shuvospecial
01/09/2026Structural Steel - High Strength BoltingShahrish Shuvospecial
01/09/2026Structural Steel - WeldingShahrish Shuvospecial
01/09/2026Subgrade InspectionsShahrish Shuvospecial
01/09/2026Post-installed AnchorsShahrish Shuvospecial
01/09/2026Structural Wood FrameShahrish Shuvoprogress
01/09/2026FinalShahrish Shuvoprogress
12/16/2025Insulation placement and R valueskimberly peckenergy_progress
12/02/2025Maintenance informationMichael McSweeneyenergy_progress
10/29/2025HVAC-R and service water heating equipmentMichael McSweeneyenergy_progress
Latest 25 of 35.
▾Documents — 70 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/18/2026B01358154-I1Request digital key ↗
08/17/2026B01286906-P4Request digital key ↗
08/17/2026B01286906-S8Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
09/22/2016340425659Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
09/22/2016340425659Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026B01286906-P3Open ↗
▸Seals & Professional Certifications39
▸DOB NOWProgress Inspector Seal & Signature20
09/02/2026B01286906-P2Open ↗
09/01/2026B01286906-S2Open ↗
09/01/2026B01286906-S2Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/17/2026B01286906-I1Open ↗
08/17/2026B01286906-P4Open ↗
08/17/2026B01286906-S8Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026B01286906-P2Open ↗
09/01/2026B01286906-S2Open ↗
08/27/2026B01286906-S1Open ↗
Showing 3 of 6 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/22/2016340425659Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/22/2016340425659Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/22/2016340425659Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist2
08/14/2026B01286906-P3Open ↗
08/14/2026B01286906-I1Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
09/22/2016340425659Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B01286906-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/17/2026B01286906-S1Open ↗
08/15/2026B01286906-S2Open ↗
08/14/2026B01286906-S5Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/22/2016340425659Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
09/22/2016340425659Open ↗
09/22/2016340425659Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
09/22/2016340425659Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification2
08/14/2026B01286906-P3Open ↗
08/14/2026B01286906-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/14/2026B01286906-P3Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026B01286906-P3Open ↗
▸DOB NOWPlot Diagram1
08/14/2026B01286906-P3Open ↗