← Back
BuildNYC
Three families
831 PRESIDENT STREET
BROOKLYN · Park Slope · BIN 3024675
💬 Discuss this project
1899Year Built
4Stories
C0Building Class
R6AZoning
6,300 sfGross Floor Area
3Units
Rent Stabilized2 Active Violations ▸FDNY Report ↗
Three families · Owner of record: 831 President Street · 1,995 sf lot · 3.16 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofRenovationUnder Construction14p · 1 filing · 20 docs
PenthouseRenovationUnder Construction1p · 1 filing · 20 docs
Floor 3RenovationUnder Construction16p · 1 filing · 20 docs
Floor 2RenovationUnder Construction16p · 1 filing · 20 docs
Floor 1RenovationUnder Construction23p · 1 filing · 20 docs
CellarRenovationUnder Construction19p · 1 filing · 20 docs
BasementRenovationUnder Construction20p · 1 filing · 20 docs
Sub-BasementRenovationUnder Construction4p · 1 filing · 20 docs
Site & exteriorProposed 4 story structureUnder Construction4p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
831 President Street103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/25/2025$3.9M—Private party → 831 PRESIDENT STREET LLC$611/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Maryclare Nepogoda503/21/2026
Casa Group203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Coppermine ConstructionGeneral Contractor207/08/2026
Callahan ContractingGeneral Contractor107/08/2026
Coppermine ConstructionScaffold107/08/2026
Rite Way HeatingPlumbing107/08/2026
Acumate ServicesGeneral Contractor109/23/2016
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Kimberly Peck Architect6812511/09/2026
Arco Engineering3769209/15/2026
Grand Millennium Consulting469107/21/2026
Shahrish Shuvo Engineering8524101/14/2026
Building Lifecycle
11/09/2026
Filed — Alteration CO
Herewith file plans for plumbing work on floors cellar, basement, 1,2,3 of proposed two family dwelling (filed in conjunction with GC application)
B01286906-P7
11/09/2026
Special inspection requirement — Insulation placement and R values
kimberly peck
11/09/2026
Special inspection requirement — Fire-Resistance Rated Construction
kimberly peck
11/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
kimberly peck
11/09/2026
Special inspection requirement — Fenestration air leakage
kimberly peck
95 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedLS Plumbing02/27/2026
DOB NOWConstruction FencePermit IssuedCoppermine Construction02/17/2026
DOB NOWGeneral ConstructionPermit IssuedCoppermine Construction02/13/2026
DOB NOWStructuralPermit IssuedCoppermine Construction02/13/2026
DOB NOWGeneral ConstructionPermit IssuedCallahan Contracting02/04/2026
BISEQISSUEDAcumate Services09/23/2016
1 project · most recent 11/09/2026
Heating and Air Conditioning Systems
FiledStatusContractorScope
11/09/2026Permit IssuedCoppermine ConstructionHeating and Air Conditioning Systems
1 project · most recent 11/09/2026
Sprinkler System
FiledStatusContractorScope
11/09/2026——Sprinkler System
1 project · most recent 11/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
11/09/2026Permit IssuedRite Way HeatingGas, Water/Sanitary
1 project · most recent 04/17/2026
General Wiring
FiledStatusContractorScope
04/17/2026Permit IssuedKepler Electrical ContGeneral Wiring
1 project · most recent 11/09/2026
Steel Concrete Masonry Wood
FiledStatusContractorScope
11/09/2026Permit IssuedRite Way HeatingSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
08/18/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
11/09/2026Insulation placement and R valueskimberly peckenergy_progress
11/09/2026Fire-Resistance Rated Constructionkimberly peckprogress
11/09/2026Fire-Resistant Penetrations and Jointskimberly peckspecial
11/09/2026Fenestration air leakagekimberly peckenergy_progress
11/09/2026Fenestration and door U-factor and product ratingskimberly peckenergy_progress
11/09/2026Lighting in dwelling unitskimberly peckenergy_progress
11/09/2026Air barrier - visual inspectionkimberly peckenergy_progress
09/18/2026Fire-Resistant Penetrations and Joints—special
09/18/2026Sprinkler Systems—special
09/14/2026FinalMichael McSweeneyprogress
09/14/2026Mechanical SystemsJOSE MANTRANAspecial
09/14/2026HVAC-R and service water piping design and insulationMichael McSweeneyenergy_progress
09/14/2026Shutoff dampersMichael McSweeneyenergy_progress
09/14/2026Maintenance informationMichael McSweeneyenergy_progress
09/14/2026HVAC-R and service water heating system controlsMichael McSweeneyenergy_progress
09/14/2026HVAC-R and service water heating equipmentMichael McSweeneyenergy_progress
07/16/2026HVAC-R and service water piping design and insulationkimberly peckenergy_progress
07/16/2026Fire-Resistant Penetrations and Jointskimberly peckspecial
03/20/2026Fenestration and door U-factor and product ratingskimberly peckenergy_progress
03/20/2026Air barrier - visual inspectionkimberly peckenergy_progress
03/20/2026Fenestration air leakagekimberly peckenergy_progress
03/20/2026Insulation placement and R valueskimberly peckenergy_progress
03/20/2026Fire-Resistant Penetrations and Jointskimberly peckspecial
03/20/2026Fire-Resistance Rated Constructionkimberly peckprogress
03/20/2026Lighting in dwelling unitskimberly peckenergy_progress
Latest 25 of 51.
87 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account