← Back
Primarily 2 family with 1 store or office
832 MANHATTAN AVENUE
BROOKLYN · BIN 3065128
💬 Discuss this project
1878Year Built
3Stories
S2Building Class
C4-3AZoning
3,891 sfGross Floor Area
3Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: 832 MANHATTAN AVE LLC · 2,123 sf lot · 1.83 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingCivil
Cellar1p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
832 MANHATTAN AVE LLC103/22/2026
MAREK KACZOR OR OWNER OF103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/09/2022$1.4M—— → —$360/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KACZOR PE611/17/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAROTTA & SON P&H CONTR CPlumbing707/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MAREK KACZOR6833511/24/2020
Building Lifecycle
All (46)Filed (6)Permit Issued (7)Signed Off (2)Violation (26)Special Inspection (5)
11/17/2025
Filed — Alteration
B01319920-I1
11/17/2025
Special inspection requirement — Final
MAREK KACZOR
12/07/2023
Violation issued (ECB, closed)
Construction
02/05/2021
Signed off — Alteration
INSTALLATION OF GAS PIPING FROM GAS BAR TO 3 BOILERS---PAA IS FILED TO SHOW GAS RISER PROTECTION FOR 1ST AND 2ND FL AS REQUESTED BY THE INSPECTOR. WORK WAS ALREADY DONE AND INSPECTED. GAS RISER IS PROTECTED BY THE PIPE CHASE AS DETAILED ON THE PLANS
B00351605-I1
12/21/2020
Permit issued — Plumbing
B20169169-I1-PL
11/30/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAREK KACZOR
11/24/2020
Filed — Alteration
INSTALLATION OF GAS PIPING FROM GAS BAR TO 3 BOILERS---PAA IS FILED TO SHOW GAS RISER PROTECTION FOR 1ST AND 2ND FL AS REQUESTED BY THE INSPECTOR. WORK WAS ALREADY DONE AND INSPECTED. GAS RISER IS PROTECTED BY THE PIPE CHASE AS DETAILED ON THE PLANS
B00351605-P1
11/24/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAREK KACZOR
11/10/2020
Signed off — Alteration
REPLACING EXISTING BOILER WITH THREE SMALL BOILERS------------PAA IS FILED TO ADD THE FOLLOWING COMMENT TO THE DRAWING P-001.01 "THE CHIMNEY IS LINED WITH TERRA-COTTA"
B00306485-I1
11/06/2020
Permit issued — Plumbing
B00351605-I1-PL
10/29/2020
Filed — Alteration
REPLACING EXISTING BOILER WITH THREE SMALL BOILERS------------PAA IS FILED TO ADD THE FOLLOWING COMMENT TO THE DRAWING P-001.01 "THE CHIMNEY IS LINED WITH TERRA-COTTA"
B00306485-P2
10/29/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAREK KACZOR
10/26/2020
Filed — Alteration
REPLACING EXISTING BOILER WITH THREE SMALL BOILERS------------PAA IS FILED TO ADD THE FOLLOWING COMMENT TO THE DRAWING P-001.01 "THE CHIMNEY IS LINED WITH TERRA-COTTA"
B00306485-P1
10/26/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAREK KACZOR
10/14/2020
Permit issued — Boiler Equipment
B00306485-I1-BE
09/29/2020
Permit issued — Plumbing
B00351605-I1-PL
09/21/2020
Permit issued — Plumbing
B20169169-I1-PL
06/01/2020
Permit issued — Plumbing
B00351605-I1-PL
05/24/2020
Filed — Alteration
INSTALLATION OF GAS PIPING FROM GAS BAR TO 3 BOILERS---PAA IS FILED TO SHOW GAS RISER PROTECTION FOR 1ST AND 2ND FL AS REQUESTED BY THE INSPECTOR. WORK WAS ALREADY DONE AND INSPECTED. GAS RISER IS PROTECTED BY THE PIPE CHASE AS DETAILED ON THE PLANS
B00351605-I1
05/11/2020
Permit issued — Boiler Equipment
B00306485-I1-BE
04/22/2020
Filed — Alteration
REPLACING EXISTING BOILER WITH THREE SMALL BOILERS------------PAA IS FILED TO ADD THE FOLLOWING COMMENT TO THE DRAWING P-001.01 "THE CHIMNEY IS LINED WITH TERRA-COTTA"
B00306485-I1
01/26/2018
Violation issued (ECB, closed)
Construction
01/10/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/24/2017
Violation issued (ECB, closed)
Construction
10/20/2017
Violation issued (ECB, closed)
Construction
10/20/2017
Violation issued (ECB, closed)
Construction
01/07/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/07/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2012
Violation issued (HPD, open)
C
02/13/2012
Violation issued (HPD, closed)
C
12/12/2009
Violation issued (ECB, closed)
Construction
11/28/2009
Violation issued (ECB, closed)
Construction
10/03/2009
Violation issued (ECB, closed)
Construction
10/03/2009
Violation issued (ECB, closed)
Unknown
06/01/2009
Violation issued (ECB, closed)
Construction
05/14/2009
Violation issued (ECB, closed)
Construction
10/18/2008
Violation issued (ECB, closed)
Construction
05/02/2008
Violation issued (ECB, closed)
Construction
05/02/2008
Violation issued (ECB, closed)
Quality of Life
04/24/2008
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/24/2008
Violation issued (ECB, closed)
Construction
04/24/2008
Violation issued (ECB, closed)
HPD
04/09/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/09/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/15/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/03/2007
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offMAROTTA & SON P&H CONTR C12/21/2020
DOB NOWPlumbingSigned-offMAROTTA & SON P&H CONTR C11/06/2020
DOB NOWBoiler EquipmentSigned-offMAROTTA & SON P&H CONTR C10/14/2020
DOB NOWPlumbingSigned-offMAROTTA & SON P&H CONTR C09/29/2020
DOB NOWPlumbingSigned-offMAROTTA & SON P&H CONTR C09/21/2020
DOB NOWPlumbingSigned-offMAROTTA & SON P&H CONTR C06/01/2020
DOB NOWBoiler EquipmentSigned-offMAROTTA & SON P&H CONTR C05/11/2020
BISPLISSUEDZARA PLUMBING CORP05/31/2017
BISOTISSUEDGRINPOINT CONSTRUCTION LL05/11/2017
BISOTISSUEDGREENPOL CONSTRUCTION LLC02/11/2014
BISOTISSUEDGREENPOL CONSTRUCTION LLC01/10/2014
BISOTISSUEDGREENPOL CONSTRUCTION LLC05/28/2013
BISOTISSUEDGREENPOL CONSTRUCTION LLC04/06/2012
BISPLISSUED21 PLUMBING & HEATING INC04/06/2012
BISOTISSUEDGREENPOL CONSTRUCTION LLC01/05/2012
BISOTISSUEDGREENPOL CONSTRUCTION LLC11/18/2011
BISPLISSUED21 PLUMBING & HEATING INC06/07/2011
BISOTISSUEDGREENPOL CONSTRUCTION LLC02/14/2011
BISOTISSUEDGREENPOL CONSTRUCTION LLC02/09/2011
BISOTISSUEDGREENPOL CONSTRUCTION LLC06/25/2010
BISOTISSUEDPARDY & SONS CONST10/12/2006
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/17/2025FinalMAREK KACZORprogress
11/30/2020Fire-Resistant Penetrations and JointsMAREK KACZORspecial
11/24/2020Fire-Resistant Penetrations and JointsMAREK KACZORspecial
10/29/2020Fire-Resistant Penetrations and JointsMAREK KACZORspecial
10/26/2020Fire-Resistant Penetrations and JointsMAREK KACZORspecial
▾Documents — 86 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - Boiler Equipment3
09/02/2026B00306485-P2Request digital key ↗
09/02/2026B00306485-I1Request digital key ↗
08/15/2026B00306485-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00351605-I1Request digital key ↗
08/15/2026B00351605-P1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/19/2026B01319920-I1Request digital key ↗
▸Applications & Permits20
▸BISPLAN / WORK APPROVAL APPLICATION9
09/21/2021320453674Open ↗
08/19/2021320453674Open ↗
04/06/2021320453674Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION8
06/02/2017302241919Open ↗
05/15/2017302241919Open ↗
01/11/2014320084975Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWLPC Approval/Permit3
08/13/2026B00351605-I1Open ↗
08/13/2026B00351605-P1Open ↗
08/13/2026B01319920-I1Open ↗
▸Seals & Professional Certifications19
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
11/14/2019320453674Open ↗
11/14/2019320453674Open ↗
10/28/2019320084975Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026B00306485-I1Open ↗
08/13/2026B00351605-P1Open ↗
08/13/2026B01319920-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/04/2026B00351605-P1Open ↗
09/02/2026B00306485-P1Open ↗
08/31/2026B00306485-P2Open ↗
Showing 3 of 4 on file for this type
▸BISPC FULL REPORT1
10/11/2007310033843Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026B01319920-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
03/27/2012320453674Open ↗
▸Safety & Tenant Protection6
▸DOB NOWTenant Protection Plan5
08/13/2026B00306485-P2Open ↗
08/13/2026B00351605-P1Open ↗
08/13/2026B00351605-I1Open ↗
Showing 3 of 5 on file for this type
▸BISSTREET TREE CHECKLIST1
10/08/2009320084975Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026B00306485-P2Open ↗
08/13/2026B00306485-P1Open ↗
08/13/2026B00306485-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
03/27/2012320453674Open ↗
10/11/2007310033843Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
10/08/2009320084975Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/14/2019320453674Open ↗
11/14/2019320453674Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
11/14/2019320453674Open ↗
▸Approvals, Objections & Sign-offs9
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
11/14/2019320453674Open ↗
11/12/2019320084975Open ↗
10/28/2019320084975Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
03/27/2012320453674Open ↗
10/08/2009320084975Open ↗
10/11/2007310033843Open ↗
▸BISSUPERSEDING LETTER1
06/02/2017302241919Open ↗
▸BISLANDMARKS APPROVAL1
10/15/2019320084975Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
11/14/2019320453674Open ↗
11/14/2019320453674Open ↗
10/15/2019320084975Open ↗
Showing 3 of 4 on file for this type
▸BISPROJECT-SPECIFIC GL INSURANCE1
05/15/2017302241919Open ↗
▸Filing & Intake Forms9
▸BISBOROUGH INTAKE FORM5
04/03/2020302247316Open ↗
11/14/2019320453674Open ↗
11/12/2019320084975Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING COVER SHEET2
03/27/2012320453674Open ↗
10/08/2009320084975Open ↗
▸BISADDITIONAL INFORMATION2
02/22/2021320453674Open ↗
02/16/2021320453674Open ↗