← Back
Two family converted from one family
836 67 STREET
BROOKLYN · BIN 3142656
💬 Discuss this project
1935Year Built
2Stories
B3Building Class
R5BZoning
1,905 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,000 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
Floor 41p · 1 filing · 6 docs
Floor 3
Floor 2Under Construction1p · 2 filings · 6 docs
Floor 1Under Construction1 filing
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SIMON JIANG505/18/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITY BUILDING NY ARCHITECT P C603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JABBIE INDUSTRIES INCORP*General Contractor409/30/2026
BEST CALL SERVICE INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SIMON7555405/18/2026
SD TESTING & INSPECTION S7010103/31/2023
Building Lifecycle
All (74)Filed (5)Permit Issued (5)Signed Off (1)Violation (1)Inspection (4)Objection (36)Special Inspection (22)
09/29/2026
Permit issued — General Construction
B01462873-I1-GC
07/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/18/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/05/2026
Permit issued — Foundation
B01283327-I1-FO
05/29/2026
Permit issued — Structural
B01283330-I1-ST
05/29/2026
Permit issued — General Construction
B01267510-I1-GC
05/18/2026
Filed — Alteration
CONSTRUCTION OF EXTENDED 4'-0" FOUNDATION WALL W/ UNEXCAVATED CELLAR IN CONJUNCTION TO JOB FILING #B01267510-I1.NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01283327-P1
05/18/2026
Special inspection requirement — Concrete - Cast-In-Place
SIMON JIANG
05/18/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SIMON JIANG
05/18/2026
Special inspection requirement — Footing and Foundation
SIMON JIANG
05/18/2026
Special inspection requirement — Final
SIMON JIANG
04/23/2026
Objection resolved — Resolved
01/16/2026
Objection raised — Other
12/19/2025
Objection resolved — Addressed
12/17/2025
Objection raised — Other
12/05/2025
Objection resolved — Addressed
11/13/2025
Objection resolved — Addressed
11/13/2025
Objection resolved — Addressed
10/24/2025
Objection raised — Zoning
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
09/16/2025
Objection raised — Other
09/16/2025
Objection resolved — Addressed
09/16/2025
Objection raised — Cost
09/16/2025
Objection resolved — Addressed
09/11/2025
Filed — Alteration
CONSTRUCTION OF EXTENDED 4'-0" FOUNDATION WALL W/ UNEXCAVATED CELLAR IN CONJUNCTION TO JOB FILING #B01267510-I1.NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01283327-I1
09/11/2025
Filed — Alteration
HORIZONTAL EXTERNSION AT THE 1ST AND 2ND FLOOR WITH CMU/BRICK WALL, WOOD JOIST, AND STEEL BEAMS IN CONJUNCTION TO JOB FILING #B01267510-I1. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01283330-I1
09/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
SIMON JIANG
09/08/2025
Special inspection requirement — Final
SIMON JIANG
09/08/2025
Special inspection requirement — Structural Wood Frame
SIMON JIANG
09/08/2025
Special inspection requirement — Masonry
SIMON JIANG
09/08/2025
Special inspection requirement — Structural Steel - High Strength Bolting
SIMON JIANG
09/08/2025
Special inspection requirement — Structural Cold-Formed Steel
SIMON JIANG
09/08/2025
Special inspection requirement — Structural Steel - Details
SIMON JIANG
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Inspections
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Zoning
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Zoning
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Fire_Protection
08/25/2025
Objection raised — Structural
08/25/2025
Objection raised — Structural
08/08/2025
Filed — Alteration
Horizontal extension at the 1st and 2nd floor. No change in use, egress or occupancy under this application.
B01267510-I1
08/06/2025
Special inspection requirement — Energy Code Compliance Inspections
SIMON JIANG
08/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SIMON JIANG
08/06/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
SIMON JIANG
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedJABBIE INDUSTRIES INCORP*09/29/2026
DOB NOWFoundationSigned-offJABBIE INDUSTRIES INCORP*06/05/2026
DOB NOWStructuralSigned-offJABBIE INDUSTRIES INCORP*05/29/2026
DOB NOWGeneral ConstructionSigned-offJABBIE INDUSTRIES INCORP*05/29/2026
DOB NOWGeneral ConstructionSigned-offBEST CALL SERVICE04/20/2023
BISPLISSUEDWASOFF PLBG & UTILITY CO07/25/2013
BIS—ISSUEDC2 CONSTRUCTION CORP07/15/2013
BISPLISSUEDWASOFF PLBG & UTILITY CO06/03/2013
BISOTISSUEDTCJ CONSTRUCTION INC05/24/2013
1 project · most recent 07/17/2026
General Wiring
FiledStatusContractorScope
07/17/2026CompleteJ Y ELECTRIC INCGeneral Wiring
2 projects · most recent 05/18/2026
Steel Wood
FiledStatusContractorScope
05/18/2026Signed-offJABBIE INDUSTRIES INCORP*1 scope_items
09/11/2025Signed-offJABBIE INDUSTRIES INCORP*Steel, Wood
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/24/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/18/2026Pass-Final PL - UndergroundPassView ↗
06/06/2023Pass-Final General Construction Non-Directive 14PassView ↗
05/18/2023Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
05/18/2026Concrete - Cast-In-PlaceSIMON JIANGspecial
05/18/2026Structural Stability – Alterations of existing buildingsSIMON JIANGspecial
05/18/2026Footing and FoundationSIMON JIANGprogress
05/18/2026FinalSIMON JIANGprogress
09/08/2025Structural Stability – Alterations of existing buildingsSIMON JIANGspecial
09/08/2025FinalSIMON JIANGprogress
09/08/2025Structural Wood FrameSIMON JIANGprogress
09/08/2025MasonrySIMON JIANGspecial
09/08/2025Structural Steel - High Strength BoltingSIMON JIANGspecial
09/08/2025Structural Cold-Formed SteelSIMON JIANGspecial
09/08/2025Structural Steel - DetailsSIMON JIANGspecial
08/06/2025Energy Code Compliance InspectionsSIMON JIANGprogress
08/06/2025Fire-Resistant Penetrations and JointsSIMON JIANGspecial
08/06/2025Structural Stability – Alterations of existing buildingsSIMON JIANGspecial
08/06/2025Fire-Resistance Rated ConstructionSIMON JIANGprogress
08/06/2025Fenestration air leakageSIMON JIANGenergy_progress
08/06/2025Fenestration areasSIMON JIANGenergy_progress
08/06/2025Fenestration and door U-factor and product ratingsSIMON JIANGenergy_progress
08/06/2025Insulation placement and R valuesSIMON JIANGenergy_progress
08/06/2025Air barrier - visual inspectionSIMON JIANGenergy_progress
03/31/2023Concrete - Cast-In-PlaceXIUCHENG LIspecial
03/31/2023MasonryXIUCHENG LIspecial
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/27/2026B00853484-I1Request digital key ↗
08/21/2026B01267510-I1Request digital key ↗
08/20/2026B01283327-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits8
▸BISWORK PERMIT APPLICATION4
08/06/2013320756703Open ↗
07/17/2013320756703Open ↗
06/06/2013320765640Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
08/14/2013320756703Open ↗
05/28/2013320765640Open ↗
05/02/2013320756703Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
10/03/2013320756703Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISADDRESS - NEW HOUSE NUMBER APPROVED1
07/03/2013320756703Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01267510-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B01267510-I1Open ↗
▸Seals & Professional Certifications20
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
12/13/2013320756703Open ↗
12/13/2013320756703Open ↗
12/13/2013320756703Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/27/2026B00853484-I1Open ↗
08/21/2026B01267510-I1Open ↗
08/20/2026B01283330-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026B01283330-I1Open ↗
08/25/2026B01267510-I1Open ↗
08/25/2026B01267510-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026B01283330-I1Open ↗
08/29/2026B00853484-I1Open ↗
08/25/2026B01267510-I1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment11
▸BISSELF-CERT PLUMBING NOTICE7
10/30/2013320756703Open ↗
10/05/2013320756703Open ↗
09/11/2013320756703Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING3
08/14/2013320756703Open ↗
05/28/2013320765640Open ↗
05/02/2013320756703Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/21/2026B01267510-I1Open ↗
▸Safety & Tenant Protection1
▸BISST-1 Street Tree Checklist1
07/03/2013320756703Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026B01267510-I1Open ↗
08/20/2026B01283327-I1Open ↗
08/15/2026B01283330-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
05/28/2013320765640Open ↗
05/02/2013320756703Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
12/13/2013320756703Open ↗
07/17/2013320756703Open ↗
05/28/2013320765640Open ↗
Showing 3 of 4 on file for this type
▸BISTR8: Energy Code Progress Inspections2
12/24/2013320765640Open ↗
07/03/2013320756703Open ↗
▸BISEN2 - As Built Energy Analysis1
12/24/2013320765640Open ↗
▸Inspections & Test Reports2
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/20/2026B01283327-I1Open ↗
08/13/2026B01283327-I1Open ↗
▸Approvals, Objections & Sign-offs9
▸BISLETTERS - SUPPORTING DOCUMENTATION3
12/24/2013320765640Open ↗
12/13/2013320756703Open ↗
12/13/2013320756703Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
05/28/2013320765640Open ↗
05/02/2013320756703Open ↗
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST2
12/30/2013320756703Open ↗
12/24/2013320765640Open ↗
▸BISSCHEDULE A - OCCUPANCY - USE2
06/29/2013320756703Open ↗
05/02/2013320756703Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
12/24/2013320765640Open ↗
12/13/2013320756703Open ↗
05/28/2013320765640Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
12/13/2013320756703Open ↗
08/19/2013320756703Open ↗
▸BISEFILING COVER SHEET2
05/28/2013320765640Open ↗
05/02/2013320756703Open ↗
▸Other Documents6
▸DOB NOWPlot Diagram3
08/20/2026B01283327-P1Open ↗
08/13/2026B01267510-I1Open ↗
08/13/2026B01283327-I1Open ↗
▸BISPlot Diagram1
07/03/2013320756703Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B01267510-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01267510-I1Open ↗