← Back
Single or multiple dwelling with stores or offices
839 57 STREET
BROOKLYN · BIN 3139893
💬 Discuss this project
1920Year Built
3Stories
S9Building Class
R6Zoning
6,150 sfGross Floor Area
6Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: 57TH STREET PROPERTY HOLDING LLC · 3,005 sf lot · 2.05 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Permit Issued — active, not yet Signed-off
Floor 1Under Construction7p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
57TH STREET PROPERTY HOLDING LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/27/2025$3.7M—— → —$602/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J&R DESIGN AND INSPECTION CORP.508/19/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HTX BUILDING CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WZ CONSULTING CORPGeneral Contractor104/09/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637508/19/2026
Building Lifecycle
All (15)Filed (5)Permit Issued (2)Objection (8)
08/19/2026
Filed — Alteration
file PL work for the 001 medical office renovation in conjunction with job #B01348675-I1 , no change in use, egress or occupancy
B01348675-P3
05/01/2026
Objection resolved — Addressed
05/01/2026
Objection resolved — Addressed
04/29/2026
Objection raised — Scope
04/29/2026
Objection raised — Scope
04/16/2026
Objection resolved — Addressed
04/15/2026
Objection raised — Scope
04/15/2026
Objection resolved — Addressed
04/15/2026
Objection raised — Inspections
04/03/2026
Filed — Alteration
file PL work for the 001 medical office renovation in conjunction with job #B01348675-I1 , no change in use, egress or occupancy
B01348675-P2
04/03/2026
Filed — Alteration
file PL work for the 001 medical office renovation in conjunction with job #B01348675-I1 , no change in use, egress or occupancy
B01348675-P1
03/24/2026
Permit issued — Plumbing
B01348675-S1-PL
03/18/2026
Permit issued — Mechanical Systems
B01348675-I1-GC-CX
01/28/2026
Filed — Alteration
file PL work for the 001 medical office renovation in conjunction with job #B01348675-I1 , no change in use, egress or occupancy
B01348675-S1
01/26/2026
Filed — Alteration
file PL work for the 001 medical office renovation in conjunction with job #B01348675-I1 , no change in use, egress or occupancy
B01348675-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG03/24/2026
DOB NOWMechanical SystemsPermit IssuedWZ CONSULTING CORP03/18/2026
BISOTISSUEDHENRYSMITH PROPERTY MGMT10/16/2015
BISPLISSUEDSO PLUMBING & HEATING INC09/02/2009
BISOTISSUEDTRIPLE 8 CONSTRUCTION INC08/13/2009
BISBLISSUEDCATMAN PLUMBING INC04/12/2007
BISPLISSUEDCATMAN PLUMBING INC08/11/2006
BIS—ISSUEDHONG KONG STYLE CONST INC07/27/2006
BISEQISSUEDHONG KONG STYLE CONST INC07/27/2006
1 project · most recent 08/19/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/19/2026Permit IssuedWZ CONSULTING CORPHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NLHZ (HEATING@54000 BTU) 48,000 BTU · Vrf Outdoor ×4
1 project · most recent 08/19/2026
Water/Sanitary
FiledStatusContractorScope
08/19/2026Signed-offJOHN FITZGERALD PLBG &HTGWater/Sanitary
2 projects · most recent 06/09/2026
FiledStatusContractorScope
06/09/2026Permit IssuedNELSON & TOM MAINT INC DB7 meters, 7 new_meters
03/24/2026CompleteCL ELECTRICAL CORP—
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
08/13/2026Fail-Final General Construction Non-Directive 14FailView ↗
02/05/2026Pass-Final CND-Occupancy InspectionPassView ↗
12/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/05/2025Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
08/18/2026Interior lighting powerRobert Truskoskyenergy_progress
08/18/2026HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
08/18/2026HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
08/18/2026Lighting controlsRobert Truskoskyenergy_progress
08/18/2026Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
08/18/2026Mechanical SystemsRobert Truskoskyspecial
08/18/2026Tenant Protection Plan Compliance—special
08/18/2026Energy Code Compliance InspectionsRobert Truskoskyprogress
08/18/2026FinalJonar Madriagaprogress
08/18/2026Fire-Resistance Rated ConstructionRobert Truskoskyprogress
08/18/2026Shutoff dampersRobert Truskoskyenergy_progress
08/18/2026MeteringRobert Truskoskyenergy_progress
08/18/2026Duct leakage testing, insulation and designRobert Truskoskyenergy_progress
05/12/2026Fire-Resistance Rated ConstructionRobert Truskoskyprogress
05/12/2026Duct leakage testing, insulation and designRobert Truskoskyenergy_progress
05/12/2026MeteringRobert Truskoskyenergy_progress
05/12/2026Shutoff dampersRobert Truskoskyenergy_progress
05/12/2026HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
05/12/2026HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
05/12/2026Interior lighting powerRobert Truskoskyenergy_progress
05/12/2026Lighting controlsRobert Truskoskyenergy_progress
05/12/2026Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
05/12/2026Mechanical SystemsRobert Truskoskyspecial
05/12/2026Tenant Protection Plan ComplianceRobert Truskoskyspecial
05/12/2026FinalJonar Madriagaprogress
Latest 25 of 34.
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026B01348675-I1Request digital key ↗
08/17/2026B01348675-S1Request digital key ↗
08/14/2026B01348675-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION4
10/14/2015340313315Open ↗
09/02/2009320050145Open ↗
08/26/2009320050145Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
10/14/2015340313315Open ↗
07/21/2009320050145Open ↗
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026B01348675-P3Open ↗
09/01/2026B01348675-P3Open ↗
09/01/2026B01348675-P3Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026B01348675-P3Open ↗
08/31/2026B01348675-S1Open ↗
08/31/2026B01348675-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026B01348675-P2Open ↗
08/17/2026B01348675-P1Open ↗
08/17/2026B01348675-S1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
02/04/2016340313315Open ↗
07/21/2009320050145Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/14/2015340313315Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/14/2015340313315Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/14/2015340313315Open ↗
▸Trade Schedules & Equipment3
▸BISSELF-CERT PLUMBING NOTICE1
03/03/2010320050145Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
07/21/2009320050145Open ↗
▸BISSCHEDULE B - PLUMBING1
07/21/2009320050145Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026B01348675-S1Open ↗
08/17/2026B01348675-I1Open ↗
08/14/2026B01348675-P1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
10/14/2015340313315Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/21/2009320050145Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/14/2015340313315Open ↗
▸Energy Compliance5
▸BISAS-BUILT ENERGY ANALYSIS1
02/04/2016340313315Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/14/2015340313315Open ↗
▸BISNYCECC ANALYSIS1
10/14/2015340313315Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/04/2016340313315Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/14/2015340313315Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
10/14/2015340313315Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
02/04/2016340313315Open ↗
02/04/2016340313315Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/04/2016340313315Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/21/2009320050145Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
02/04/2016340313315Open ↗
10/14/2015340313315Open ↗
07/21/2009320050145Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION1
11/19/2015340313315Open ↗
▸BISEFILING COVER SHEET1
07/21/2009320050145Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/14/2015340313315Open ↗