← Back
Two family converted from one family
84-04 108 STREET
QUEENS · BIN 4191802
💬 Discuss this project
1925Year Built
2.75Stories
B3Building Class
R4AZoning
1,782 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 84-04 L.P. · 2,850 sf lot · 0.63 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction2p · 3 filings · 18 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/13/2023$865K—— → —$485/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SELF EMPLOYED403/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Younes Abouyaala PE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&J PLG & HTG CO OF NY INPlumbing307/08/2026
OASIS PLOMO CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519403/18/2025
Building Lifecycle
All (20)Filed (4)Permit Issued (4)Signed Off (1)Inspection (5)Special Inspection (6)
11/24/2025
Signed off — Alteration
Q01138303-I1
11/19/2025
Permit issued — General Construction
Q01138303-I1-GC
10/14/2025
Permit issued — Plumbing
Q93438834-I1-PL
04/02/2025
Permit issued — Plumbing
Q93438834-I1-PL
04/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
04/02/2025
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
03/18/2025
Filed — Alteration
THIS PLUMBING APPLICATION IS FILED IN CONJUNTION WITH GC APPLICATION #Q01138303-I1 FOR PLUMBING WORK TO REPLACE EXISTING BOILERS, ADD NEW TANKLESS HWH, ADD SECOND GAS METER.
Q01138492-P2
03/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
03/18/2025
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
02/14/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/03/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/03/2025
Inspection — Certified Gas-Gas-Piping-Underground
Certified
View inspection ↗
02/03/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/20/2025
Filed — Alteration
THIS PLUMBING APPLICATION IS FILED IN CONJUNTION WITH GC APPLICATION #Q01138303-I1 FOR PLUMBING WORK TO REPLACE EXISTING BOILERS, ADD NEW TANKLESS HWH, ADD SECOND GAS METER.
Q01138492-P1
01/14/2025
Permit issued — Plumbing
Q01138492-I1-PL
01/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
01/14/2025
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
12/09/2024
Filed — Alteration
Q01138303-I1
12/09/2024
Filed — Alteration
THIS PLUMBING APPLICATION IS FILED IN CONJUNTION WITH GC APPLICATION #Q01138303-I1 FOR PLUMBING WORK TO REPLACE EXISTING BOILERS, ADD NEW TANKLESS HWH, ADD SECOND GAS METER.
Q01138492-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offOASIS PLOMO CORP11/19/2025
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN10/14/2025
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN04/02/2025
DOB NOWPlumbingSigned-offL&J PLG & HTG CO OF NY IN01/14/2025
1 project · most recent 03/18/2025
Gas Water/Sanitary
FiledStatusContractorScope
03/18/2025Signed-offL&J PLG & HTG CO OF NY INGas, Water/Sanitary
1 project · most recent 09/19/2024
General Wiring
FiledStatusContractorScope
09/19/2024Permit IssuedTRINCITY ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/03/2025Certified Gas-Gas-Piping-UndergroundCertifiedView ↗
02/03/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
04/02/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
04/02/2025Energy Code Compliance InspectionsYounes Abouyaalaprogress
03/18/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
03/18/2025Energy Code Compliance InspectionsYounes Abouyaalaprogress
01/14/2025Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
01/14/2025Energy Code Compliance InspectionsYounes Abouyaalaprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01138303-I1Request digital key ↗
08/20/2026Q01138492-P2Request digital key ↗
08/20/2026Q01138492-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01138303-I1Open ↗
08/13/2026Q01138492-I1Open ↗
08/13/2026Q01138492-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/30/2026Q01138492-P2Open ↗
08/25/2026Q01138492-P1Open ↗
08/22/2026Q01138492-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/30/2026Q01138492-P2Open ↗
08/25/2026Q01138492-P1Open ↗
08/22/2026Q01138492-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/21/2026Q01138303-I1Open ↗
08/13/2026Q01138492-P2Open ↗
08/13/2026Q01138492-P1Open ↗
Showing 3 of 4 on file for this type