← Back
STATEN ISLAND
84 NIXON AVENUE
STATEN ISLAND · Tompkinsville-Stapleton-Clifton-Fox Hills · BIN 5107934
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Locations of Work
ArchitectureStructuralElectrical
Roof11p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
THE OWNER OF 82 NIXION AV103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NKM ENGINEERING PLLC105/06/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INFINITY SOLAR SYSTEMS.LLGeneral Contractor107/30/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244105/06/2026
Building Lifecycle
All (15)Filed (1)Permit Issued (1)Violation (6)Objection (2)Special Inspection (5)
07/29/2026
Permit issued — Solar
S01371759-I1-SL
06/29/2026
Objection resolved — Addressed
05/27/2026
Objection raised — Other
05/06/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
S01371759-I1
03/13/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
03/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/13/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/13/2026
Special inspection requirement — Final
NARESH MAHANGU
03/13/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
10/01/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/15/2003
Violation issued (ECB, closed)
Construction
10/08/1993
Violation issued (ECB, closed)
Construction
12/11/1989
Violation issued (ECB, closed)
Construction
09/14/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedINFINITY SOLAR SYSTEMS.LL07/29/2026
BISPLISSUEDKEYSPAN PLUMBING SOLUTIONS INC08/29/2000
BIS—ISSUEDKEVIN HOSMER08/17/2000
2 projects · most recent 04/30/2026
General Wiring
FiledStatusContractorScope
04/30/2026Permit IssuedHARRINGTON ELECT CONTR IN—
04/09/2026CancelledHARRINGTON ELECT CONTR INGeneral Wiring
1 project · most recent 05/06/2026
FiledStatusContractorScope
05/06/2026Permit IssuedINFINITY SOLAR SYSTEMS.LL26 panels, 11.44 kw, 1,567 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/13/2026Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
03/13/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/13/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/13/2026FinalNARESH MAHANGUprogress
03/13/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026S01371759-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026S01371759-I1Open ↗
09/02/2026S01371759-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026S01371759-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/02/2026S01371759-I1Open ↗