← Back
Four families
844 41 STREET
BROOKLYN · BIN 3018230
💬 Discuss this project
1914Year Built
2Stories
C3Building Class
R6Zoning
3,120 sfGross Floor Area
4Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Four families · Owner of record: STH & LIN REALTY LLC · 2,504 sf lot · 1.25 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Roof2p · 2 filings · 16 docs
Floor 22p · 1 filing · 12 docs
Floor 11p · 1 filing · 4 docs
Cellar5p · 2 filings · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
STH & LIN REALTY LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/12/2025$2.2M—844 41ST STREET LLC → STH & LIN REALTY LLC$692/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI506/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor303/21/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394306/19/2025
Building Lifecycle
All (46)Filed (5)Permit Issued (2)Signed Off (2)Violation (24)Inspection (4)Special Inspection (9)
05/01/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, closed)
I
07/24/2025
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW YARD DRAIN AT REAR YARD; NEW WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE,EGRESS OR OCCUPANCY UNDER THIS APPLI
B01183672-I1
07/15/2025
Signed off — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; REPLAC ECONCRETE STAIR AT REAR YARD. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01183670-I1
07/14/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/23/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
06/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
06/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
06/19/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; REPLAC ECONCRETE STAIR AT REAR YARD. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01183670-P2
06/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
06/19/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
06/19/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
06/06/2025
Violation issued (HPD, open)
A
05/07/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/07/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/05/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/30/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW YARD DRAIN AT REAR YARD; NEW WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE,EGRESS OR OCCUPANCY UNDER THIS APPLI
B01183672-P1
04/30/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; REPLAC ECONCRETE STAIR AT REAR YARD. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01183670-P1
04/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
04/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
02/27/2025
Permit issued — Plumbing
B01183672-I1-PL
02/26/2025
Permit issued — General Construction
B01183670-I1-GC
02/21/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH PLUMBING WORK:RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW YARD DRAIN AT REAR YARD; NEW WASHER, DRYER, BOILERS AND HOT WATER HEATERS IN CELLAR; NO CHANGE IN USE,EGRESS OR OCCUPANCY UNDER THIS APPLI
B01183672-I1
02/21/2025
Filed — Alteration
RENOVATION OF EXISTING CELLAR, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION: NEW PARTITIONS, DOORS, FLOORING AND COSMETIC WORK; REPLAC ECONCRETE STAIR AT REAR YARD. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01183670-I1
02/22/2022
Violation issued (HPD, closed)
A
04/06/2021
Violation issued (HPD, closed)
A
01/20/2021
Violation issued (HPD, closed)
C
01/20/2021
Violation issued (HPD, closed)
C
01/20/2021
Violation issued (HPD, closed)
C
01/20/2021
Violation issued (HPD, closed)
C
01/20/2021
Violation issued (HPD, closed)
C
12/19/2020
Violation issued (HPD, closed)
C
12/16/2020
Violation issued (HPD, closed)
C
12/16/2020
Violation issued (HPD, closed)
C
12/16/2020
Violation issued (HPD, closed)
B
12/16/2020
Violation issued (HPD, closed)
A
12/04/2020
Violation issued (HPD, closed)
A
12/04/2020
Violation issued (HPD, closed)
A
12/01/2020
Violation issued (HPD, closed)
B
12/01/2020
Violation issued (HPD, closed)
B
12/01/2020
Violation issued (HPD, closed)
B
05/26/2020
Violation issued (HPD, closed)
C
05/26/2020
Violation issued (HPD, closed)
B
05/26/2020
Violation issued (HPD, closed)
B
12/19/2013
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC02/27/2025
DOB NOWGeneral ConstructionSigned-offKALE CONSTRUCTION INC02/26/2025
2 projects · most recent 08/25/2022
General Wiring
FiledStatusContractorScope
08/25/2022CompleteMANGI ELECTRICAL CORP5 meters, 5 new_meters
02/08/2021CompleteMANGI ELECTRICAL CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/14/2025Pass-Final General Construction Non-Directive 14PassView ↗
05/07/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/07/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/05/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
06/23/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
06/23/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
06/23/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
06/19/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
06/19/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
06/19/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
04/30/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
04/30/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
04/30/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/22/2026B01183672-P1Request digital key ↗
08/22/2026B01183672-I1Request digital key ↗
08/21/2026B01183670-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/22/2026B01183672-P1Open ↗
08/22/2026B01183672-I1Open ↗
08/21/2026B01183670-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026B01183670-P2Open ↗
08/27/2026B01183670-P1Open ↗
08/22/2026B01183670-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026B01183670-P2Open ↗
08/27/2026B01183670-P1Open ↗
08/22/2026B01183670-I1Open ↗