← Back
Miscellaneous hospital / health care facility
85-07 66 AVENUE
QUEENS · BIN 4074047
💬 Discuss this project
1978Year Built
3Stories
I9Building Class
R3-1Zoning
3,314 sfGross Floor Area
4Units
7 Open Violations 6 unresolved · 1 paperwork only ▸
Miscellaneous hospital / health care facility · 3,219 sf lot · 1.03 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CEREBRAL PALSY ASSN OF NYS707/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAMES E. VASSALOTTI III & ASSOC.306/06/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
VAA303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FPS CONTRACTING INCGeneral Contractor207/08/2026
JD MASTERS PLBG & HTGPlumbing107/08/2026
Building Lifecycle
All (26)Filed (3)Permit Issued (3)Signed Off (2)Violation (14)Inspection (2)Special Inspection (2)
06/14/2023
Signed off — Alteration
Propose to install plumbing fixtures as per plans filed herewith. No change in use egress or occupancy proposed under this application.
Q08024631-I1
06/06/2023
Filed — Alteration
Propose to install plumbing fixtures as per plans filed herewith. No change in use egress or occupancy proposed under this application.
Q08024631-P1
05/23/2023
Signed off — Alteration
Propose to remove and install some interior non bearing partitions as per plans filed herewith. No change in use egress or occupancy is proposed under this application.
Q08024621-I1
03/06/2023
Permit issued — General Construction
Q08024621-I1-GC
02/08/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/08/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/09/2023
Permit issued — Plumbing
Q08024631-I1-PL
11/30/2022
Permit issued — General Construction
Q08024621-I1-GC
10/26/2022
Filed — Alteration
Propose to install plumbing fixtures as per plans filed herewith. No change in use egress or occupancy proposed under this application.
Q08024631-I1
10/26/2022
Filed — Alteration
Propose to remove and install some interior non bearing partitions as per plans filed herewith. No change in use egress or occupancy is proposed under this application.
Q08024621-I1
10/26/2022
Special inspection requirement — Air barrier - visual inspection
JAMES VASSALOTTI III
10/20/2022
Special inspection requirement — Final
JAMES VASSALOTTI III
11/20/2018
Violation issued (ECB, closed)
Construction
02/13/2018
Violation issued (ECB, open)
Boilers
01/01/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/16/1999
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/04/1998
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/16/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/06/1992
Violation issued (ECB, closed)
Construction
11/08/1989
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offFPS CONTRACTING INC03/06/2023
DOB NOWPlumbingSigned-offJD MASTERS PLBG & HTG01/09/2023
DOB NOWGeneral ConstructionSigned-offFPS CONTRACTING INC11/30/2022
BISOTISSUEDRS CONSTRACTING INC07/29/2005
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
02/08/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/08/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
10/26/2022Air barrier - visual inspectionJAMES VASSALOTTI IIIenergy_progress
10/20/2022FinalJAMES VASSALOTTI IIIprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026Q08024621-I1Request digital key ↗
08/24/2026Q08024631-I1Request digital key ↗
08/24/2026Q08024631-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q08024621-I1Open ↗
08/24/2026Q08024631-P1Open ↗
08/24/2026Q08024631-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q08024621-I1Open ↗
08/25/2026Q08024621-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026Q08024621-I1Open ↗
08/24/2026Q08024631-P1Open ↗
08/24/2026Q08024631-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter3
08/13/2026Q08024621-I1Open ↗
08/13/2026Q08024631-P1Open ↗
08/13/2026Q08024631-I1Open ↗