| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/28/2025 | Permit Issued | K&P BUILDERS CORP | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MSZ-GS06NA 6,000 BTU · Split System ×5 MSZ-GS09NA 12,200 BTU · Split System ×3 MXZ-3C24NAHZ4 23,600 BTU · Heat Pump Outdoor ×3 MSZ-FS15NA 19,000 BTU · Split System ×2 MUZ-FS15NA 14,000 BTU · Heat Pump Outdoor ×2 Comfort Aire RSG1348S1M 4 tons · Condensing Unit ×1 Heating Goodman GMVC960403BNB 40,000 BTU · Furnace ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/13/2025 | Permit Issued | M & M PIPING AND HEATING | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/13/2025 | Complete | ELECTRICAL SVCS & CONS GP | General Wiring |
| 03/04/2020 | Complete | NEWGRANGE ELECTRIC, INC | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/28/2025 | Permit Issued | K&P BUILDERS CORP | Steel, Masonry, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/28/2025 | Permit Issued | K&P BUILDERS CORP | Earthwork |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 11/06/2020 | $635K | — | Private party → Private party | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| M.S. SAVANI ARCHITECT, PC | 6 | 08/13/2025 |
| ARCHITECTURAL CONCEPT | 1 | 03/04/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| ARCASTLE | 10 | 03/21/2026 |
| ARCHITECTUAL CONCEPT | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| K&P BUILDERS CORP | General Contractor | 8 | 07/08/2026 |
| SHARAN CONSTRUCTION INC | General Contractor | 2 | 07/08/2026 |
| M & M PIPING AND HEATING | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ARCHITECTURAL CONCEPT | 3642 | 4 | 08/13/2025 |
| IP CONCRETE TESTING AND I | 6252 | 2 | 07/28/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Earth Work | Permit Issued | K&P BUILDERS CORP | 06/02/2025 |
| DOB NOW | Plumbing | Permit Issued | M & M PIPING AND HEATING | 08/22/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | K&P BUILDERS CORP | 06/13/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | K&P BUILDERS CORP | 06/13/2024 |
| DOB NOW | Full Demolition | Signed-off | K&P BUILDERS CORP | 05/21/2024 |
| DOB NOW | Construction Fence | Signed-off | SHARAN CONSTRUCTION INC | 11/21/2023 |
| DOB NOW | Construction Fence | Signed-off | SHARAN CONSTRUCTION INC | 06/26/2023 |
| Date | Type | Result | Report |
|---|---|---|---|
| 12/30/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/04/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 09/04/2024 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 09/04/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 09/04/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/04/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/28/2025 | Exterior Insulation and Finish Systems (EIFS) | INDARDEO PARBHUNATH | special |
| 07/28/2025 | Fire-Resistant Penetrations and Joints | MUZAFFAR JAMAL | special |
| 07/28/2025 | Masonry | MUZAFFAR JAMAL | special |
| 07/28/2025 | Mastic and Intumescent Fire-resistant Coatings | INDARDEO PARBHUNATH | special |
| 07/28/2025 | Mechanical Systems | MUZAFFAR JAMAL | special |
| 07/28/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | MUZAFFAR JAMAL | special |
| 07/28/2025 | Subgrade Inspections | MUZAFFAR JAMAL | special |
| 07/28/2025 | Subsurface Investigations (Borings/Test Pits) | INDARDEO PARBHUNATH | special |
| 07/28/2025 | Wall Panels, Curtain Walls, and Veneers | MUZAFFAR JAMAL | special |
| 07/28/2025 | Energy Code Compliance Inspections | MUZAFFAR JAMAL | progress |
| 07/28/2025 | Final | TARIQ SIDDIQUI | progress |
| 07/28/2025 | Fire-Resistance Rated Construction | MUZAFFAR JAMAL | progress |
| 07/28/2025 | Footing and Foundation | MUZAFFAR JAMAL | progress |
| 07/28/2025 | Electric vehicle service equipment requirements | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | HVAC-R and service water heating system controls | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Air barrier — testing | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | HVAC-R and service water piping design and insulation | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Maintenance information | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Fenestration air leakage | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Duct leakage testing, insulation and design | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Interior lighting power | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Insulation placement and R values | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Air barrier - visual inspection | MUZAFFAR JAMAL | energy_progress |
| 07/28/2025 | Concrete - Cast-In-Place | MUZAFFAR JAMAL | special |
| 07/28/2025 | Excavations - Sheeting, Shoring, and Bracing | MUZAFFAR JAMAL | special |