← Back
BuildNYC
Two stories - detached, small or mid-size
85-42 CHEVY CHASE STREET
QUEENS · BIN 4213546
💬 Discuss this project
1935Year Built
2Stories
A1Building Class
R1-2Zoning
1,824 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 7,790 sf lot · 0.23 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof2p · 1 filing · 20 docs
Floor 219p · 2 filings · 20 docs
Floor 1Morgorodski curb cut15p · 3 filings · 20 docs
Cellar20p · 2 filings · 20 docs
Site & exteriorTemporary construction fence2p · 1 filing · 3 docs
Filed — no permit issuedFence installation2p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Foam Inc Magic203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/03/2023$1.3M—Private party → Private party$724/sf building
09/12/2017$969K—Private party → Private party$531/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Haym S. Gross, Architect405/03/2024
Rike Tech Associates304/07/2023
HC Engineering206/01/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Britz Enterprises1403/21/2026
A D Building Solutions403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Best MatchScaffold1007/08/2026
Magic FoamScaffold603/21/2026
Magic FoamGeneral Contractor303/21/2026
Best MatchGeneral Contractor303/21/2026
All Pro Plumbing & HeatingPlumbing207/08/2026
Best Matchspecialty_contractor107/08/2026
Rock E Small Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Rike Tech Associates2965705/03/2024
Building Lifecycle
09/04/2024
Signed off — Alteration
APPLICATION FILED FOR GUT REHAB EXISTING ONE FAMILY DWELLING, NEW FRONT ENTRANCE ADDITION OF 18 SQ. FT. AND A VERTICAL ENLARGE AT REAR 2ND.FL. 346 sfOVER EXISTING FIRST FLOOR.
Q00653968-I1
09/03/2024
Permit issued — Structural
Q00653968-I1-MS
08/30/2024
Signed off — Alteration
temp construction fence; scaffolding
Q00767059-I1
07/26/2024
Signed off — Alteration
minor plumbing work at cellar, 001,002
Q00653277-I1
06/26/2024
At time of inspection, observed at exposure 1, lot frontage is 40FT and 25FT deep. Planting area approximately 120 sqft (10X12FT). Removal of…
ECB violation · closed
70 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offBest Match09/03/2024
DOB NOWConstruction FenceSigned-offBest Match09/11/2023
DOB NOWConstruction FenceSigned-offBest Match09/08/2023
DOB NOWConstruction FenceSigned-offBest Match08/29/2023
DOB NOWConstruction FenceSigned-offBest Match08/25/2023
DOB NOWGeneral ConstructionSigned-offBest Match08/16/2023
DOB NOWPlumbingSigned-offRock E Small Plumbing & Heating07/06/2023
DOB NOWPlumbingSigned-offAll Pro Plumbing & Heating03/16/2023
DOB NOWSupported ScaffoldSigned-offMagic Foam07/01/2022
DOB NOWConstruction FenceSigned-offMagic Foam07/01/2022
DOB NOWGeneral ConstructionSigned-offMagic Foam06/17/2022
DOB NOWPlumbingSigned-offAll Pro Plumbing & Heating02/01/2022
2 projects · most recent 05/03/2024
General Wiring
FiledStatusContractorScope
05/03/2024CompleteIndy ElectricGeneral Wiring
12/30/2021CompleteMLS ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
05/01/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/29/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/21/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/21/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 55
DateRequirementInspectorRole
05/03/2024Energy Code Compliance InspectionsSYED RIZVIprogress
05/03/2024Fire-Resistant Penetrations and JointsSYED RIZVIspecial
05/01/2024Fire-Resistant Penetrations and JointsSYED RIZVIspecial
05/01/2024Energy Code Compliance InspectionsSYED RIZVIprogress
07/24/2023Lighting in dwelling unitsSYED RIZVIenergy_progress
07/24/2023Fenestration and door U-factor and product ratingsSYED RIZVIenergy_progress
07/24/2023Fenestration areasSYED RIZVIenergy_progress
07/24/2023Fire-Resistant Penetrations and JointsSYED RIZVIspecial
07/24/2023Concrete - Cast-In-PlaceSYED RIZVIspecial
07/24/2023Structural Steel - WeldingSYED RIZVIspecial
07/24/2023Mechanical SystemsSYED RIZVIspecial
07/24/2023MasonrySYED RIZVIspecial
07/24/2023Structural Steel - High Strength BoltingSYED RIZVIspecial
07/24/2023FinalHAYM GROSSprogress
07/24/2023Fire-Resistance Rated ConstructionSYED RIZVIprogress
07/24/2023Structural Wood FrameSYED RIZVIprogress
07/24/2023Energy Code Compliance InspectionsSYED RIZVIprogress
07/24/2023Fenestration air leakageSYED RIZVIenergy_progress
07/24/2023Air barrier - visual inspectionSYED RIZVIenergy_progress
07/24/2023Interior lighting powerSYED RIZVIenergy_progress
05/24/2023Energy Code Compliance InspectionsSYED RIZVIprogress
05/24/2023Fire-Resistant Penetrations and JointsSYED RIZVIspecial
03/27/2023Structural Steel - High Strength BoltingSYED RIZVIspecial
03/27/2023Concrete - Cast-In-PlaceSYED RIZVIspecial
03/27/2023Fire-Resistant Penetrations and JointsSYED RIZVIspecial
Latest 25 of 55.