← Back
Two family converted from one family
85-71 67 ROAD
QUEENS · BIN 4074285
💬 Discuss this project
1932Year Built
2Stories
B3Building Class
R4Zoning
1,360 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two family converted from one family · 2,000 sf lot · 0.68 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
INC HARRY'S CONTRACTING103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BORGESE ARCHITECTURE607/22/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HARRY'S CONTRACTING INCGeneral Contractor303/21/2026
DYNAMIC BLUE WATER MECHPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INTEGRITY CONSULTING SERV666107/08/2023
Building Lifecycle
All (13)Filed (6)Permit Issued (2)Signed Off (2)Violation (3)
10/24/2024
Signed off — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-I1
10/07/2024
Signed off — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-S2
07/22/2024
Filed — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-P5
04/25/2024
Filed — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-P3
01/12/2024
Filed — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-P2
12/07/2023
Permit issued — Plumbing
Q00890160-S2-PL
10/24/2023
Filed — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-S2
10/13/2023
Filed — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-S1
09/28/2023
Violation issued (ECB, closed)
Unknown
08/17/2023
Permit issued — Structural
Q00890160-I1-GC-CX
07/08/2023
Filed — Alteration
Provide all new domestic cold/hot water plumbing, sanitary waste, and vent piping and roughing to cellar bathroom,1st floor bathroom, 1st floor kitchen, and 2nd floor bathroom. Existing gas piping to removed and capped back at the source.
Q00890160-I1
03/27/1999
Violation issued (ECB, closed)
Quality of Life
03/27/1999
Violation issued (ECB, open)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSUPER PLUMBERS CORP12/07/2023
DOB NOWStructuralSigned-offHARRY'S CONTRACTING INC08/17/2023
1 project · most recent 07/22/2024
Water/Sanitary
FiledStatusContractorScope
07/22/2024Signed-offSUPER PLUMBERS CORPWater/Sanitary
2 projects · most recent 04/12/2024
General Wiring
FiledStatusContractorScope
04/12/2024CompleteFOREST ELECTRIC CORP.General Wiring
01/23/2023Permit IssuedALL WAYS ELECTRIC CORP.W—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/04/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/29/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/31/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
06/30/2023Air barrier - visual inspectionFRANCESCO BORGESEenergy_progress
06/30/2023Structural Stability – Alterations of existing buildingsALEKSANDR LEVINspecial
06/30/2023Fire-Resistant Penetrations and JointsALEKSANDR LEVINspecial
06/30/2023Energy Code Compliance InspectionsFRANCESCO BORGESEprogress
06/30/2023Fire-Resistance Rated ConstructionFRANCESCO BORGESEprogress
06/30/2023Structural Wood FrameFRANCESCO BORGESEprogress
06/30/2023Lighting in dwelling unitsFRANCESCO BORGESEenergy_progress
06/30/2023Fenestration and door U-factor and product ratingsFRANCESCO BORGESEenergy_progress
06/14/2023FinalFRANCESCO BORGESEprogress
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026Q00890160-P3Request digital key ↗
08/21/2026Q00890160-P2Request digital key ↗
08/21/2026Q00890160-S2Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00890160-I1Open ↗
▸DOB NOWRestrictive Declaration1
08/13/2026Q00890160-S2Open ↗
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature7
08/24/2026Q00890160-I1Open ↗
08/24/2026Q00890160-I1Open ↗
08/24/2026Q00890160-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/21/2026Q00890160-P5Open ↗
08/21/2026Q00890160-P3Open ↗
08/21/2026Q00890160-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026Q00890160-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026Q00890160-P3Open ↗
08/21/2026Q00890160-P2Open ↗
08/21/2026Q00890160-S2Open ↗
Showing 3 of 6 on file for this type
▸Other Documents3
▸DOB NOWPlot Diagram1
08/13/2026Q00890160-I1Open ↗
▸DOB NOWPro Cert Restriction Exception (LL158/17)1
08/13/2026Q00890160-S1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00890160-I1Open ↗