← Back
Two family converted from one family
858 FOX STREET
BRONX · BIN 2086602
💬 Discuss this project
1987Year Built
3Stories
B3Building Class
R7-1Zoning
1,980 sfGross Floor Area
2Units
0 Open Violations
Two family converted from one family · 2,200 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 31p · 1 filing · 20 docs
Floor 22p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COMPLEX DEVELOPMENT503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
OMF ARCHITECT PC905/23/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
TREASURE BOX SERVICES1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
COMPLEX DEVELOPMENT INCGeneral Contractor807/08/2026
SIGNORE & SONS PLBG CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519303/22/2024
OMF ARCHITECTS PC5900503/22/2024
PROMISE CONSULTANTS1412104/26/2022
Building Lifecycle
All (57)Filed (9)Permit Issued (6)Signed Off (2)Violation (5)Inspection (5)Special Inspection (30)
07/22/2024
Signed off — Alteration
PLUMBING AT 2ND FLOOR, CHANGES OF GAS EQUIPMENT AND REPLACED FIXTURES ENLARGEMENT in connection with an EXTENSION UNDER APPLICATION # X00558053.
X00668411-I1
07/15/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/08/2024
Signed off — Alteration
PROPOSED NEW EXTENSION AT REAR FOR FIRST AND SECOND FLOOR AS PER PLANS SUBMITTED. NO CHANGE OF USE, EGRESS, OR OCCUPANCY.
X00558053-I1
05/29/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/29/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/28/2024
Special inspection requirement — Permanent certificate
OSCAR FUERTES
05/28/2024
Special inspection requirement — HVAC-R and service water heating equipment
OSCAR FUERTES
05/28/2024
Special inspection requirement — HVAC-R and service water heating system controls
OSCAR FUERTES
05/23/2024
Filed — Alteration
PLUMBING AT 2ND FLOOR, CHANGES OF GAS EQUIPMENT AND REPLACED FIXTURES ENLARGEMENT in connection with an EXTENSION UNDER APPLICATION # X00558053.
X00668411-P3
05/23/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/23/2024
Special inspection requirement — HVAC-R and service water heating equipment
OSCAR FUERTES
05/23/2024
Special inspection requirement — HVAC-R and service water heating system controls
OSCAR FUERTES
05/23/2024
Special inspection requirement — Permanent certificate
OSCAR FUERTES
05/15/2024
Filed — Alteration
PLUMBING AT 2ND FLOOR, CHANGES OF GAS EQUIPMENT AND REPLACED FIXTURES ENLARGEMENT in connection with an EXTENSION UNDER APPLICATION # X00558053.
X00668411-P2
05/09/2024
Special inspection requirement — Permanent certificate
OSCAR FUERTES
05/09/2024
Special inspection requirement — HVAC-R and service water heating equipment
OSCAR FUERTES
05/09/2024
Special inspection requirement — HVAC-R and service water heating system controls
OSCAR FUERTES
04/29/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/11/2024
Permit issued — Plumbing
X00668411-I1-PL
03/26/2024
Special inspection requirement — Masonry
OSCAR FUERTES
03/26/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
OSCAR FUERTES
03/26/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
03/26/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
OSCAR FUERTES
03/26/2024
Special inspection requirement — Air barrier — testing
OSCAR FUERTES
03/26/2024
Special inspection requirement — Insulation placement and R values
OSCAR FUERTES
03/26/2024
Special inspection requirement — Fenestration areas
OSCAR FUERTES
03/26/2024
Special inspection requirement — Final
OSCAR FUERTES
03/26/2024
Special inspection requirement — Footing and Foundation
OSCAR FUERTES
03/26/2024
Special inspection requirement — Energy Code Compliance Inspections
OSCAR FUERTES
03/26/2024
Special inspection requirement — Structural Steel - Details
Younes Abouyaala
03/22/2024
Filed — Alteration
PROPOSED NEW EXTENSION AT REAR FOR FIRST AND SECOND FLOOR AS PER PLANS SUBMITTED. NO CHANGE OF USE, EGRESS, OR OCCUPANCY.
X00558053-P4
03/22/2024
Filed — Alteration
PLUMBING AT 2ND FLOOR, CHANGES OF GAS EQUIPMENT AND REPLACED FIXTURES ENLARGEMENT in connection with an EXTENSION UNDER APPLICATION # X00558053.
X00668411-P1
08/19/2022
Special inspection requirement — Permanent certificate
OSCAR FUERTES
08/19/2022
Special inspection requirement — HVAC-R and service water heating system controls
OSCAR FUERTES
08/19/2022
Special inspection requirement — HVAC-R and service water heating equipment
OSCAR FUERTES
04/29/2022
Permit issued — Structural
X00558053-I1-GC
04/26/2022
Filed — Alteration
PROPOSED NEW EXTENSION AT REAR FOR FIRST AND SECOND FLOOR AS PER PLANS SUBMITTED. NO CHANGE OF USE, EGRESS, OR OCCUPANCY.
X00558053-P3
04/25/2022
Special inspection requirement — Structural Steel - Details
Younes Abouyaala
04/22/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
04/22/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
OSCAR FUERTES
04/22/2022
Special inspection requirement — Masonry
OSCAR FUERTES
04/22/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
JUNG Y SHIN
04/22/2022
Special inspection requirement — Energy Code Compliance Inspections
OSCAR FUERTES
04/22/2022
Special inspection requirement — Final
OSCAR FUERTES
04/18/2022
Violation issued (ECB, closed)
Construction
04/18/2022
Violation issued (ECB, closed)
Construction
04/18/2022
Violation issued (ECB, closed)
Construction
04/18/2022
Violation issued (ECB, closed)
Construction
04/18/2022
Violation issued (ECB, closed)
Construction
02/08/2022
Permit issued — Foundation
X00558053-I1-FO
02/08/2022
Permit issued — General Construction
X00558053-I1-GC
02/08/2022
Permit issued — Foundation
X00558053-I1-ST
02/02/2022
Filed — Alteration
PROPOSED NEW EXTENSION AT REAR FOR FIRST AND SECOND FLOOR AS PER PLANS SUBMITTED. NO CHANGE OF USE, EGRESS, OR OCCUPANCY.
X00558053-P2
01/28/2022
Permit issued — Plumbing
X00668411-I1-PL
01/26/2022
Filed — Alteration
PLUMBING AT 2ND FLOOR, CHANGES OF GAS EQUIPMENT AND REPLACED FIXTURES ENLARGEMENT in connection with an EXTENSION UNDER APPLICATION # X00558053.
X00668411-I1
01/22/2022
Filed — Alteration
PROPOSED NEW EXTENSION AT REAR FOR FIRST AND SECOND FLOOR AS PER PLANS SUBMITTED. NO CHANGE OF USE, EGRESS, OR OCCUPANCY.
X00558053-P1
09/27/2021
Filed — Alteration
PROPOSED NEW EXTENSION AT REAR FOR FIRST AND SECOND FLOOR AS PER PLANS SUBMITTED. NO CHANGE OF USE, EGRESS, OR OCCUPANCY.
X00558053-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offSIGNORE & SONS PLBG CORP04/11/2024
DOB NOWStructuralSigned-offCOMPLEX DEVELOPMENT INC04/29/2022
DOB NOWFoundationSigned-offCOMPLEX DEVELOPMENT INC02/08/2022
DOB NOWGeneral ConstructionSigned-offCOMPLEX DEVELOPMENT INC02/08/2022
DOB NOWFoundationSigned-offCOMPLEX DEVELOPMENT INC02/08/2022
DOB NOWPlumbingSigned-offSIGNORE & SONS PLBG CORP01/28/2022
BIS—ISSUEDUMANA DESIGNS INC04/01/2011
BISOTISSUEDWEST NEW YORK RESTORATION INC.05/29/1998
1 project · most recent 03/16/2022
General Wiring
FiledStatusContractorScope
03/16/2022Permit IssuedRIVIERA ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/15/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/29/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/29/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/23/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/29/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 55
DateRequirementInspectorRole
05/28/2024Permanent certificateOSCAR FUERTESenergy_progress
05/28/2024HVAC-R and service water heating equipmentOSCAR FUERTESenergy_progress
05/28/2024HVAC-R and service water heating system controlsOSCAR FUERTESenergy_progress
05/23/2024HVAC-R and service water heating equipmentOSCAR FUERTESenergy_progress
05/23/2024HVAC-R and service water heating system controlsOSCAR FUERTESenergy_progress
05/23/2024Permanent certificateOSCAR FUERTESenergy_progress
05/09/2024Permanent certificateOSCAR FUERTESenergy_progress
05/09/2024HVAC-R and service water heating equipmentOSCAR FUERTESenergy_progress
05/09/2024HVAC-R and service water heating system controlsOSCAR FUERTESenergy_progress
03/26/2024MasonryOSCAR FUERTESspecial
03/26/2024Fire-Resistant Penetrations and JointsOSCAR FUERTESspecial
03/26/2024Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
03/26/2024Fenestration and door U-factor and product ratingsOSCAR FUERTESenergy_progress
03/26/2024Air barrier — testing OSCAR FUERTESenergy_progress
03/26/2024Insulation placement and R valuesOSCAR FUERTESenergy_progress
03/26/2024Fenestration areasOSCAR FUERTESenergy_progress
03/26/2024FinalOSCAR FUERTESprogress
03/26/2024Footing and FoundationOSCAR FUERTESprogress
03/26/2024Energy Code Compliance InspectionsOSCAR FUERTESprogress
03/26/2024Structural Steel - DetailsYounes Abouyaalaspecial
08/19/2022Permanent certificateOSCAR FUERTESenergy_progress
08/19/2022HVAC-R and service water heating system controlsOSCAR FUERTESenergy_progress
08/19/2022HVAC-R and service water heating equipmentOSCAR FUERTESenergy_progress
04/25/2022Structural Steel - DetailsYounes Abouyaalaspecial
04/22/2022Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
Latest 25 of 55.
▾Documents — 127 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/24/2026X00558053-P4Request digital key ↗
08/24/2026X00558053-P2Request digital key ↗
08/24/2026X00558053-P1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION4
03/21/2012220049310Open ↗
03/17/2010220049310Open ↗
02/18/2010220039688Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
04/01/2011220049310Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram5
08/24/2026X00558053-P2Open ↗
08/24/2026X00558053-P1Open ↗
08/24/2026X00558053-I1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications61
▸DOB NOWProgress Inspector Seal & Signature36
09/01/2026X00668411-I1Open ↗
09/01/2026X00668411-I1Open ↗
09/01/2026X00668411-I1Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
08/30/2026X00558053-P3Open ↗
08/30/2026X00558053-P3Open ↗
08/30/2026X00558053-P3Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/24/2026X00558053-P3Open ↗
08/24/2026X00558053-P2Open ↗
08/24/2026X00558053-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
03/17/2010220049310Open ↗
12/02/2009220039688Open ↗
02/28/2012220049310Open ↗
▸Trade Schedules & Equipment4
▸BISSELF-CERT PLUMBING NOTICE3
03/30/2012220049310Open ↗
09/29/2010220049310Open ↗
09/27/2010220049310Open ↗
▸BISSCHEDULE B - PLUMBING1
03/17/2010220049310Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
03/17/2010220049310Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/24/2026X00558053-P3Open ↗
08/24/2026X00558053-P1Open ↗
08/24/2026X00558053-P2Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
03/17/2010220049310Open ↗
12/02/2009220039688Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026X00668411-I1Open ↗
08/13/2026X00558053-I1Open ↗
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
03/30/2012220049310Open ↗
02/28/2012220049310Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
03/17/2010220049310Open ↗
02/18/2010220039688Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
03/23/2010220049310Open ↗
12/02/2009220039688Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
04/02/2012220049310Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT4
02/28/2012220049310Open ↗
03/17/2010220049310Open ↗
02/18/2010220039688Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026X00558053-I1Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026X00558053-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/17/2010220049310Open ↗
▸Other Documents15
▸DOB NOWPlot Diagram5
08/24/2026X00558053-P2Open ↗
08/24/2026X00558053-P1Open ↗
08/24/2026X00558053-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/24/2026X00558053-I1Open ↗
08/24/2026X00558053-P3Open ↗
08/24/2026X00558053-P2Open ↗
Showing 3 of 5 on file for this type
▸BISPLOT DIAGRAM2
03/17/2010220049310Open ↗
12/02/2009220039688Open ↗
▸DOB NOWSite Survey: Initial2
08/24/2026X00558053-I1Open ↗
08/13/2026X00558053-P4Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026X00558053-I1Open ↗