← Back
Two stories - detached, small or mid-size
86-08 EDGERTON BOULEVARD
QUEENS · Jamaica Estates-Holliswood · BIN 4211300
💬 Discuss this project
1930Year Built
2.75Stories
A1Building Class
R1-2Zoning
2,887 sfGross Floor Area
1Units
2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Two stories - detached, small or mid-size · 9,040 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Roof4p · 2 filings · 20 docs
Floor 2Under Construction26p · 1 filing · 20 docs
Floor 1Under Construction25p · 1 filing · 20 docs
CellarUnder Construction28p · 3 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/11/2023$1.2M—— → —$416/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SERDAR CEYLAN ARCHITECT, PC1108/13/2026
TOM PETERSEN ARCHITECT, LLC102/26/2025
JUST CONSULTING ENGINEERING310/14/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Mdl consulting services303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYC BUILDING SOLUTIONS COGeneral Contractor603/21/2026
SB RENOVATION & MODELINGGeneral Contractor304/09/2026
SOLARBLOCKS ENERGY LLCGeneral Contractor104/09/2026
GREGG NY PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES74951008/13/2026
THOMAS PETERSEN ARCHITECT7854102/26/2025
DOYUN KIM; RA7415310/14/2024
Building Lifecycle
All (74)Filed (15)Permit Issued (7)Signed Off (2)Violation (5)Inspection (6)Objection (9)Special Inspection (30)
08/13/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
HORIZONTAL EXTENSION OF THE EXISTING ONE-FAMILY HOUSE AS PER PLANS SUBMITTED.
Q01011927-P5
07/08/2026
Violation issued (ECB, open)
Construction
07/01/2026
Signed off — Alteration
The scope of work pertains exclusively to the installation of the solar system. Any additional tasks or activities should not be assumed as approved or permitted by the NYC Department of Buildings. No change to use, egress, or occupancy.
Q01186809-I1
06/15/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
06/15/2026
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
06/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
06/15/2026
Special inspection requirement — HVAC-R and service water heating equipment
Rajasekhar Sakhamuri
06/11/2026
Violation issued (ECB, open)
Construction
06/09/2026
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AND GAS EQUIPMENT IN CONJUNCTION WITH CONSTRUCTION JOB #Q01011927-I1 ON EXIST. ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00986065-P4
06/09/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
HORIZONTAL EXTENSION OF THE EXISTING ONE-FAMILY HOUSE AS PER PLANS SUBMITTED.
Q01011927-P4
04/30/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/01/2026
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AND GAS EQUIPMENT IN CONJUNCTION WITH CONSTRUCTION JOB #Q01011927-I1 ON EXIST. ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00986065-P3
03/18/2026
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
03/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
03/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
03/18/2026
Special inspection requirement — HVAC-R and service water heating equipment
Rajasekhar Sakhamuri
03/13/2026
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE AS PER PLANS SUBMITTED. NO CHANGEIN USE, EGRESS OR OCCUPANCY.
Q00999235-I1
01/05/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/16/2025
Objection resolved — Addressed
12/12/2025
Objection raised — Other
12/04/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
11/27/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
HORIZONTAL EXTENSION OF THE EXISTING ONE-FAMILY HOUSE AS PER PLANS SUBMITTED.
Q01011927-P3
11/27/2025
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AND GAS EQUIPMENT IN CONJUNCTION WITH CONSTRUCTION JOB #Q01011927-I1 ON EXIST. ONE FAMILY HOUSE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00986065-P2
11/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
11/26/2025
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
10/14/2025
Special inspection requirement — Insulation placement and R values
JEFFREY BELL
10/14/2025
Special inspection requirement — Lighting controls
JEFFREY BELL
10/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
JEFFREY BELL
10/14/2025
Special inspection requirement — Permanent certificate
JEFFREY BELL
10/14/2025
Special inspection requirement — Ventilation and air distribution system
JEFFREY BELL
10/14/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
JEFFREY BELL
10/14/2025
Special inspection requirement — Electric vehicle service equipment requirements
JEFFREY BELL
10/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
JEFFREY BELL
10/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
10/14/2025
Special inspection requirement — Air barrier — testing
10/14/2025
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
10/14/2025
Special inspection requirement — Interior lighting power
JEFFREY BELL
10/14/2025
Special inspection requirement — Fenestration air leakage
JEFFREY BELL
10/14/2025
Special inspection requirement — Protection of exposed foundation insulation
JEFFREY BELL
10/14/2025
Special inspection requirement — Fenestration areas
JEFFREY BELL
10/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
JEFFREY BELL
10/14/2025
Special inspection requirement — Mechanical Systems
Rajasekhar Sakhamuri
10/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
JEFFREY BELL
10/14/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Rajasekhar Sakhamuri
10/14/2025
Special inspection requirement — Energy Code Compliance Inspections
JEFFREY BELL
04/11/2025
Permit issued — Construction Fence
Q00999235-I1-FN
02/28/2025
Permit issued — Solar
Q01186809-I1-SL
02/26/2025
Filed — Alteration
The scope of work pertains exclusively to the installation of the solar system. Any additional tasks or activities should not be assumed as approved or permitted by the NYC Department of Buildings. No change to use, egress, or occupancy.
Q01186809-I1
01/10/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/25/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/17/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
HORIZONTAL EXTENSION OF THE EXISTING ONE-FAMILY HOUSE AS PER PLANS SUBMITTED.
Q01011927-P2
10/17/2024
Violation issued (ECB, closed)
Construction
10/14/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
HORIZONTAL EXTENSION OF THE EXISTING ONE-FAMILY HOUSE AS PER PLANS SUBMITTED.
Q01011927-P1
09/20/2024
Permit issued — Plumbing
Q00986065-I1-PL
06/07/2024
Permit issued — Structural
Q01011927-S2-ST
06/07/2024
Permit issued — Foundation
Q01011927-S1-FO-EA
05/23/2024
Objection resolved — Addressed
05/13/2024
Objection raised — Other
05/07/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
HORIZONTAL EXTENSION OF THE EXISTING ONE-FAMILY HOUSE AS PER PLANS SUBMITTED.
Q01011927-S1
Latest 60 of 74 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offNYC BUILDING SOLUTIONS CO04/11/2025
DOB NOWSolarSigned-offSOLARBLOCKS ENERGY LLC02/28/2025
DOB NOWPlumbingSigned-offGREGG NY PLUMBING, INC09/20/2024
DOB NOWStructuralPermit IssuedSB RENOVATION & MODELING06/07/2024
DOB NOWFoundationPermit IssuedSB RENOVATION & MODELING06/07/2024
DOB NOWMechanical SystemsPermit IssuedSB RENOVATION & MODELING05/02/2024
DOB NOWConstruction FenceSigned-offNYC BUILDING SOLUTIONS CO04/12/2024
2 projects · most recent 08/13/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/13/2026Permit IssuedSB RENOVATION & MODELINGHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PUMY-P60NKMU3 (2) MXZ-SM60NAM2 5 BTU · Heat Pump Outdoor ×3
MXZ-SM60NAM 5 tons · Condensing Unit ×6
01/03/2024——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NAM 5 tons · Condensing Unit ×2
1 project · most recent 06/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/09/2026Signed-offGREGG NY PLUMBING, INCGas, Water/Sanitary
2 projects · most recent 02/17/2025
General Wiring
FiledStatusContractorScope
02/17/2025CompleteMDC SECURITY AND ELEC'L—
04/18/2024CompleteWCK ELECTRIC CORP.General Wiring
1 project · most recent 08/13/2026
Steel Wood
FiledStatusContractorScope
08/13/2026Permit IssuedSB RENOVATION & MODELINGSteel, Wood
1 project · most recent 02/26/2025
FiledStatusContractorScope
02/26/2025Signed-offSOLARBLOCKS ENERGY LLC45 panels, 19.35 kw, 2,459 roof_area_sqft
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
04/30/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/05/2026Pass-Final CND-Occupancy InspectionPassView ↗
12/04/2025Fail-Final CND-Occupancy InspectionFailView ↗
01/10/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/25/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 64
DateRequirementInspectorRole
06/15/2026Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
06/15/2026HVAC-R and service water heating equipmentRajasekhar Sakhamurienergy_progress
06/15/2026HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
06/15/2026Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
03/18/2026Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
03/18/2026HVAC-R and service water heating equipmentRajasekhar Sakhamurienergy_progress
03/18/2026HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
03/18/2026Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
11/26/2025Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
11/26/2025Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
10/14/2025Air barrier - visual inspectionJEFFREY BELLenergy_progress
10/14/2025Concrete - Cast-In-PlaceRajasekhar Sakhamurispecial
10/14/2025Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
10/14/2025Mechanical SystemsRajasekhar Sakhamurispecial
10/14/2025Structural Stability – Alterations of existing buildingsRajasekhar Sakhamurispecial
10/14/2025Energy Code Compliance InspectionsJEFFREY BELLprogress
10/14/2025FinalJEFFREY BELLprogress
10/14/2025Fire-Resistance Rated ConstructionJEFFREY BELLprogress
10/14/2025Air barrier — testing —energy_progress
10/14/2025Permanent certificateJEFFREY BELLenergy_progress
10/14/2025Protection of exposed foundation insulationJEFFREY BELLenergy_progress
10/14/2025HVAC-R and service water heating system controlsJEFFREY BELLenergy_progress
10/14/2025Fenestration areasJEFFREY BELLenergy_progress
10/14/2025Fenestration air leakageJEFFREY BELLenergy_progress
10/14/2025Lighting controlsJEFFREY BELLenergy_progress
Latest 25 of 64.
▾Documents — 130 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/23/2026Q00978415-I1Request digital key ↗
08/23/2026Q00999235-I1Request digital key ↗
08/21/2026Q01011927-S1Request digital key ↗
Showing 3 of 15 on file for this type
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram6
08/21/2026Q01011927-P5Open ↗
08/21/2026Q01011927-P4Open ↗
08/13/2026Q01011927-I1Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications74
▸DOB NOWProgress Inspector Seal & Signature43
09/21/2026Q01011927-P1Open ↗
09/21/2026Q01011927-P1Open ↗
09/02/2026Q00986065-P3Open ↗
Showing 3 of 43 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature16
09/21/2026Q01011927-P1Open ↗
09/02/2026Q00986065-P3Open ↗
09/01/2026Q01011927-S2Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/21/2026Q01011927-S1Open ↗
08/21/2026Q01011927-S2Open ↗
08/21/2026Q01011927-P1Open ↗
Showing 3 of 15 on file for this type
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report14
08/21/2026Q01011927-S1Open ↗
08/21/2026Q01011927-S2Open ↗
08/21/2026Q01011927-P1Open ↗
Showing 3 of 14 on file for this type
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01011927-S1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/20/2026Q01186809-I1Open ↗
▸Other Documents19
▸DOB NOWSite Survey: Initial6
08/21/2026Q01011927-P5Open ↗
08/21/2026Q01011927-P4Open ↗
08/13/2026Q01011927-P3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/21/2026Q01011927-P4Open ↗
08/21/2026Q01011927-P5Open ↗
08/13/2026Q01011927-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProperty Ownership Certification5
08/21/2026Q01011927-P2Open ↗
08/21/2026Q01011927-P5Open ↗
08/21/2026Q01011927-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01011927-S1Open ↗
▸DOB NOWPlot Diagram1