← Back
Two stories - detached, small or mid-size
86-22 SOMERSET STREET
QUEENS · BIN 4213232
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R1-2Zoning
2,523 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 5,080 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Floor 26p · 1 filing · 20 docs
Floor 17p · 1 filing · 20 docs
Cellar8p · 2 filings · 20 docs
1 job · most recent 10/17/2024
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
10/17/2024Permit IssuedVINTAGE HOMES INCAir Conditioning Systems, Heating Systems
Cooling
Carrier 24ABB336ABN3 3 tons · Condensing Unit ×3
24ABB348ABN3 4 tons · Condensing Unit ×3
Hydron HYT024 29,200 BTU · Ahu ×2
Heating
Carrier 59SC2D080E17 80,000 BTU · Furnace ×3
59SC2D100E21 100,000 BTU · Furnace ×3
Hydron HYT024 23,400 BTU · Ahu ×2
1 job · most recent 11/04/2022
General Wiring
FiledStatusContractorScope
11/04/2022CompleteJOE ELECTRICAL INCGeneral Wiring
1 job · most recent 10/17/2024
FiledStatusContractorScope
10/17/2024Permit IssuedVINTAGE HOMES INC4 scope_items
1 job · most recent 10/17/2024
Earthwork
FiledStatusContractorScope
10/17/2024Permit IssuedVINTAGE HOMES INCEarthwork
Building Lifecycle
All (74)Filed (7)Permit Issued (16)Signed Off (2)Violation (2)Inspection (7)Objection (10)Special Inspection (30)
12/12/2024
Special inspection requirement — Masonry
KOJO SIMPSON
12/12/2024
Special inspection requirement — Subgrade Inspections
KOJO SIMPSON
12/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
KOJO SIMPSON
12/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
KOJO SIMPSON
12/12/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
12/12/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
KOJO SIMPSON
12/12/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
KOJO SIMPSON
12/12/2024
Special inspection requirement — Heating Systems
KOJO SIMPSON
12/12/2024
Special inspection requirement — Concrete - Cast-In-Place
KOJO SIMPSON
12/12/2024
Special inspection requirement — Final
KOJO SIMPSON
12/12/2024
Special inspection requirement — Energy Code Compliance Inspections
KOJO SIMPSON
12/12/2024
Special inspection requirement — Fire-Resistance Rated Construction
KOJO SIMPSON
12/12/2024
Special inspection requirement — Footing and Foundation
KOJO SIMPSON
12/12/2024
Special inspection requirement — Mechanical Systems
KOJO SIMPSON
12/12/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
KOJO SIMPSON
12/12/2024
Special inspection requirement — HVAC-R and service water heating equipment
KOJO SIMPSON
12/12/2024
Special inspection requirement — Interior lighting power
KOJO SIMPSON
12/12/2024
Special inspection requirement — Metering
KOJO SIMPSON
12/12/2024
Special inspection requirement — Fenestration air leakage
KOJO SIMPSON
12/12/2024
Special inspection requirement — Air barrier - visual inspection
KOJO SIMPSON
12/12/2024
Special inspection requirement — Protection of exposed foundation insulation
KOJO SIMPSON
12/12/2024
Special inspection requirement — Ventilation and air distribution system
KOJO SIMPSON
12/12/2024
Special inspection requirement — Electric vehicle service equipment requirements
KOJO SIMPSON
12/12/2024
Special inspection requirement — Insulation placement and R values
KOJO SIMPSON
12/12/2024
Special inspection requirement — Permanent certificate
KOJO SIMPSON
12/12/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
KOJO SIMPSON
12/12/2024
Special inspection requirement — Maintenance information
KOJO SIMPSON
12/12/2024
Special inspection requirement — HVAC-R and service water heating system controls
KOJO SIMPSON
12/12/2024
Special inspection requirement — Fenestration areas
KOJO SIMPSON
12/01/2024
Objection resolved — Addressed
10/31/2024
Objection raised — Other
10/17/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED FOR HORIZONTAL AND VERTICAL ENLARGEMENT, INTERIOR AND EXTERIOR RENOVATION AND INSTALLATION OF HVAC TO AN EXISTING ONE FAMILY DWELLING
Q00617998-P6
10/14/2024
Special inspection requirement — Concrete - Cast-In-Place
KOJO SIMPSON
10/08/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/28/2024
Signed off — Alteration
INSTALLATION OF PLUMBING EQUIPMENT AND FIXTURES IN CONJUNCTION WITH APPLICATION NO. Q00617998.
Q00651364-I1
08/17/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED FOR HORIZONTAL AND VERTICAL ENLARGEMENT, INTERIOR AND EXTERIOR RENOVATION AND INSTALLATION OF HVAC TO AN EXISTING ONE FAMILY DWELLING
Q00617998-P5
07/03/2024
Permit issued — Plumbing
Q00651364-I1-PL
12/18/2023
Signed off — Alteration
HEREWITH FILED FOR TEMPORARY CONSTRUCTION FENCE ALONG PROPERTY LINE
Q00588928-I1
08/17/2023
Permit issued — Construction Fence
Q00588928-I1-FN
03/06/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/06/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
02/17/2023
Filed — Alteration
INSTALLATION OF PLUMBING EQUIPMENT AND FIXTURES IN CONJUNCTION WITH APPLICATION NO. Q00617998.
Q00651364-P1
02/06/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/03/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/01/2023
Violation issued (ECB, closed)
Construction
02/01/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/06/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/30/2022
Permit issued — Foundation
Q00617998-I1-GC
12/20/2022
Permit issued — Mechanical Systems
Q00617998-I1-GC
12/20/2022
Permit issued — Mechanical Systems
Q00617998-I1-MS
12/20/2022
Permit issued — Construction Fence
Q00588928-I1-FN
12/12/2022
Permit issued — Mechanical Systems
Q00617998-I1-MS
12/12/2022
Permit issued — Foundation
Q00617998-I1-GC
12/12/2022
Permit issued — Construction Fence
Q00588928-I1-FN
11/15/2022
Permit issued — Plumbing
Q00651364-I1-PL
11/15/2022
Permit issued — Earth Work
Q00617998-I1-MS
11/11/2022
Permit issued — Construction Fence
Q00588928-I1-FN
11/09/2022
Permit issued — Mechanical Systems
Q00617998-I1-GC
10/05/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
APPLICATION FILED FOR HORIZONTAL AND VERTICAL ENLARGEMENT, INTERIOR AND EXTERIOR RENOVATION AND INSTALLATION OF HVAC TO AN EXISTING ONE FAMILY DWELLING
Q00617998-P1
07/29/2022
Permit issued — Foundation
Q00617998-I1-GC
Latest 60 of 74 events.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/22/2021$695K—Private party → Private party$275/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KOJO SIMPSON ARCHITECT710/17/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GO SOLAR/GREEN NY LLCGeneral Contractor3903/21/2026
VINTAGE HOMES INCGeneral Contractor203/21/2026
G.M.A. PLUMBING & HEATINGPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KOJO SIMPSON ARCHITECT1664610/17/2024
TRIANGLE INSPECTION & TES7495202/17/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offG.M.A. PLUMBING & HEATING07/03/2024
DOB NOWConstruction FenceSigned-offGO SOLAR/GREEN NY LLC08/17/2023
DOB NOWFoundationPermit IssuedSUPREME GENERAL CONTNG CO12/30/2022
DOB NOWMechanical SystemsPermit IssuedGO SOLAR/GREEN NY LLC12/20/2022
DOB NOWMechanical SystemsSigned-offGO SOLAR/GREEN NY LLC12/20/2022
DOB NOWConstruction FenceSigned-offGO SOLAR/GREEN NY LLC12/20/2022
DOB NOWMechanical SystemsSigned-offGO SOLAR/GREEN NY LLC12/12/2022
DOB NOWFoundationPermit IssuedGO SOLAR/GREEN NY LLC12/12/2022
DOB NOWConstruction FenceSigned-offGO SOLAR/GREEN NY LLC12/12/2022
DOB NOWPlumbingSigned-offG.M.A. PLUMBING & HEATING11/15/2022
DOB NOWEarth WorkSigned-offGO SOLAR/GREEN NY LLC11/15/2022
DOB NOWConstruction FenceSigned-offGO SOLAR/GREEN NY LLC11/11/2022
DOB NOWMechanical SystemsPermit IssuedGO SOLAR/GREEN NY LLC11/09/2022
DOB NOWFoundationPermit IssuedGO SOLAR/GREEN NY LLC07/29/2022
DOB NOWGeneral ConstructionSigned-offGO SOLAR/GREEN NY LLC07/26/2022
DOB NOWConstruction FenceSigned-offGO SOLAR/GREEN NY LLC06/20/2022
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
10/08/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/06/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/06/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/06/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/03/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/01/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/06/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 122
DateRequirementInspectorRole
12/12/2024Subgrade InspectionsKOJO SIMPSONspecial
12/12/2024MasonryKOJO SIMPSONspecial
12/12/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationKOJO SIMPSONspecial
12/12/2024Structural Stability – Alterations of existing buildingsKOJO SIMPSONspecial
12/12/2024Fire-Resistant Penetrations and JointsKOJO SIMPSONspecial
12/12/2024Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
12/12/2024Mechanical SystemsKOJO SIMPSONspecial
12/12/2024Excavations - Sheeting, Shoring, and BracingKOJO SIMPSONspecial
12/12/2024Heating SystemsKOJO SIMPSONspecial
12/12/2024Concrete - Cast-In-PlaceKOJO SIMPSONspecial
12/12/2024FinalKOJO SIMPSONprogress
12/12/2024Energy Code Compliance InspectionsKOJO SIMPSONprogress
12/12/2024Fire-Resistance Rated ConstructionKOJO SIMPSONprogress
12/12/2024Footing and FoundationKOJO SIMPSONprogress
12/12/2024Fenestration areasKOJO SIMPSONenergy_progress
12/12/2024Fenestration and door U-factor and product ratingsKOJO SIMPSONenergy_progress
12/12/2024HVAC-R and service water heating equipmentKOJO SIMPSONenergy_progress
12/12/2024Interior lighting powerKOJO SIMPSONenergy_progress
12/12/2024MeteringKOJO SIMPSONenergy_progress
12/12/2024Fenestration air leakageKOJO SIMPSONenergy_progress
12/12/2024Air barrier - visual inspectionKOJO SIMPSONenergy_progress
12/12/2024Protection of exposed foundation insulationKOJO SIMPSONenergy_progress
12/12/2024Ventilation and air distribution systemKOJO SIMPSONenergy_progress
12/12/2024Electric vehicle service equipment requirementsKOJO SIMPSONenergy_progress
12/12/2024Insulation placement and R valuesKOJO SIMPSONenergy_progress
Latest 25 of 122.
▾Documents — 174 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/27/2026Q00588928-I1Request digital key ↗
08/25/2026Q00651364-P1Request digital key ↗
08/21/2026Q00617998-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram4
08/21/2026Q00617998-P1Open ↗
08/21/2026Q00617998-P5Open ↗
08/15/2026Q00617998-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00617998-I1Open ↗
▸Seals & Professional Certifications129
▸DOB NOWProgress Inspector Seal & Signature78
09/01/2026Q00617998-P1Open ↗
09/01/2026Q00617998-P1Open ↗
09/01/2026Q00617998-P1Open ↗
Showing 3 of 78 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature44
09/01/2026Q00617998-P1Open ↗
09/01/2026Q00617998-P1Open ↗
09/01/2026Q00617998-P1Open ↗
Showing 3 of 44 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026Q00651364-I1Open ↗
08/21/2026Q00617998-I1Open ↗
08/21/2026Q00617998-P5Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00617998-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00617998-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00617998-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026Q00617998-P5Open ↗
08/21/2026Q00617998-P1Open ↗
08/15/2026Q00651364-I1Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00617998-I1Open ↗
▸Inspections & Test Reports9
▸DOB NOWSOIL REPORT6
08/21/2026Q00617998-P1Open ↗
08/21/2026Q00617998-P5Open ↗
08/15/2026Q00651364-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026Q00617998-I1Open ↗
08/13/2026Q00651364-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00617998-I1Open ↗
▸Other Documents14
▸DOB NOWSite Survey: Initial4
08/21/2026Q00617998-P5Open ↗
08/15/2026Q00617998-I1Open ↗
08/13/2026Q00617998-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/21/2026Q00617998-P5Open ↗
08/21/2026Q00617998-P1Open ↗
08/15/2026Q00617998-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/21/2026Q00617998-P5Open ↗
08/21/2026Q00617998-P1Open ↗
08/15/2026Q00617998-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026Q00617998-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00617998-I1Open ↗