| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 06/08/2017 | $910K | — | — → — | $801/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| D&E BUILD EVERGREEN INC. | 3 | 04/25/2025 |
| PETER CHO ARCHITECTS, PLLC | 1 | 04/23/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| METRO DESIGN CONSULTANTS INC | 8 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| D&E BUILD EVERGREEN I | 9342 | 2 | 04/25/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | OT | ISSUED | N/A | 03/23/1994 |
| BIS | PL | ISSUED | VITELLO P & MECHANICAL INC | 03/18/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/25/2025 | — | — | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Goodman GSXN3N6010A 60,000 BTU · Condensing Unit ×2 Heating Goodman GM9S921005CN 100,000 BTU · Furnace ×1 Ventilation Hampton Bay 7114-01 50 CFM · Exhaust Fan ×7 Janska RHW-3652 520 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/25/2025 | — | — | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/25/2025 | — | — | Steel, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/25/2025 | — | — | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/09/2025 | Structural Stability – Alterations of existing buildings | Danny Chen | special |
| 04/20/2025 | Structural Stability – Alterations of existing buildings | Danny Chen | special |
| 04/20/2025 | Subsurface Investigations (Borings/Test Pits) | INDARDEO PARBHUNATH | special |
| 04/20/2025 | Concrete - Cast-In-Place | Danny Chen | special |
| 04/20/2025 | Excavations - Sheeting, Shoring, and Bracing | Danny Chen | special |
| 04/20/2025 | Fire-Resistant Penetrations and Joints | Danny Chen | special |
| 04/20/2025 | Masonry | Danny Chen | special |
| 04/20/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Danny Chen | special |
| 04/20/2025 | Structural Steel - High Strength Bolting | Danny Chen | special |
| 04/20/2025 | Subgrade Inspections | Danny Chen | special |
| 04/20/2025 | Final | PETER CHO | progress |
| 04/20/2025 | Footing and Foundation | Danny Chen | progress |
| 04/20/2025 | Energy Code Compliance Inspections | Danny Chen | progress |
| 04/20/2025 | Fire-Resistance Rated Construction | Danny Chen | progress |
| 04/20/2025 | Structural Wood Frame | Danny Chen | progress |
| 04/20/2025 | Electric vehicle service equipment requirements | Danny Chen | energy_progress |
| 04/20/2025 | Fenestration and door U-factor and product ratings | Danny Chen | energy_progress |
| 04/20/2025 | Fenestration air leakage | Danny Chen | energy_progress |
| 04/20/2025 | Fenestration areas | Danny Chen | energy_progress |
| 04/20/2025 | Metering | Danny Chen | energy_progress |
| 04/20/2025 | Insulation placement and R values | Danny Chen | energy_progress |
| 04/20/2025 | Permanent certificate | Danny Chen | energy_progress |
| 04/20/2025 | Air barrier - visual inspection | Danny Chen | energy_progress |
| 04/20/2025 | Interior lighting power | Danny Chen | energy_progress |
| 04/20/2025 | Maintenance information | Danny Chen | energy_progress |