DOB07/30/2026BOROUGH COMMISSIONER HAS ORDERED WORK STOPPED FOR APPLICATION # Q08014337-I1 (WR000013949) DUE TO APPLICANT WITHDRAWAL. STOP ALL WORK IMMEDIATELY & MAKE THE SITE SAFE. PLEASE CONTACT BOROUGH COMMISSIONER AT 718-286-7670. SWO NOTICE # OP-71-25-06892.
ECB05/05/2026IN RESPONSE TO A WORKER FALLING FROM THE 5TH STORY TO THE 3RD STORY WHILE WORKING ON THE AN INCOMPLETE SUPPORTED SCAFFOLD, IT WAS REVEALED THAT THE WORKER WAS NOT TRAINED TO BE ON THE SCAFFOLD, WASN'T GIVEN A H$10K due
ECB05/05/2026ON FEBRUARY 5, 2026 COMPLAINT #:4A24367 THIS SITE WAS PUT ON A STOP WORK ORDER ON THE SUPPORTED SCAFFOLD, WITH NO RESCIND. ON MAY 5, 2026 A WORKER FELL FROM THE 5TH STORY TO THE 3RD STORY WHILE WORKING ON THE S$10K due
ECB05/05/2026IN RESPONSE TO AN INCIDENT WERE A WORKER WAS PERFORMING WORK ON A SUPPORTED SCAFFOLD & FELL FROM THE 5TH STORY TO THE 3RD STORY IT WAS REVEALED THAT THE WORKER WAS ONLY THERE TO PROVIDE HOUSEKEEPING & WAS NEVER$5K due
ECB03/12/2026FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. OBSERVED: SITE WITH MULTIPLE AREAS OF HOUSEKEEPING ISSUES LIKE EXPOSURE 4, AND CELLAR ALIKE CONCRETE PILE BLACK PLASTICS BAGS, WOOD IN OTHERS,
ECB02/05/2026OBSERVED POWER LINES ON EXP 2 OF THE SITE WITHIN REACH OF A PIPE SCAFFOLD, ELECTRICAL CABLE WAS NOT PROPERLY PROTECTED OR INSULATED TO PREVENT CONTACT BY WORKERS UTILIZING THE SCAFFOLD. THIS CONDITION EXPOSES W$2K due
DOB08/28/2020BORO COMMISSIONER HAS ORDERED WORK STOPPED FOR # 420300533 D UE TO GENERAL CONTRACTOR WITHDRAWAL
DOB06/17/2016V-DOB VIOLATION - ACTIVE
ECB08/20/201228-407.1 FAILURE TO HAVE WELDER LICENSE FOR MANUAL STRUCTURAL WELDING NOTED AT STRUCTURAL FRAME BLDG UNDER CONSTRUCTION AT 3RD FL LVL EXP 2 CONSTRUCTION WORKER MANUAL WELDING TO STEEL 1 BEAM W/ NO CERTIFIED WEL$-195 due
ECB10/03/2012SEC. 28-116.2.3. FAILURE TO PROVIDE AN ADEQUATE INSPECTION PROGRAM. ASNOTED: AT TIME OF INSPECTION STEEL STRUCTURAL NEW BLDG IS UP TO 2 STORIES. FAILURE TO PROVIDE AN ADEQUATE INSPECTION PROGRAM TR1 FOR SPECIALNothing owed — awaiting certificate of correction
ECB10/03/2012WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS OR APPROVED AMENDMENTS. AS NOTED: AT TIME OF INSPECTION AT FLR #1 EXP #3 OBSERVED DOUBLE ROW OF CMU BLOCKS W/MISSING VERTICAL (DOWELS) REBARS. APPROVEDNothing owed — awaiting certificate of correction
ECB09/26/2012SEC. 3301.7. FAILURE TO PROVIDE PE APPROVED DESIGN DRAWING. AS NOTED: AT TIME OF INSPECTION AT FLR #1 EXP #1 AND #2 OBSERVE CMU BLOCKS EMBEDDED IN CONCRETE DECK AND BLOCK AND BRICK PLACEMENT AROUND STEEL COLUMNNothing owed — awaiting certificate of correction
ECB08/20/2012NOTED AT STEEL FRAME BLDG UNDER CONSTRUCTION FOR NB#420300533 APPROVED STRUCTURAL PLAN SHOWS A490 HS BOLTS AT MOMENT CONNECTIONS WHERE AS A325 HS 7/8 HAVE BEEN USED 2ND AND 3RD FLOOR MOMENT CONNECTION STEEL PLANothing owed — awaiting certificate of correction
ECB08/20/2012NOTED 6 STORY PROPOSED STEEL FRAME AT 3RD STORY HAS NO ROOF PROTECTION FOR ADJACENT PROPERTY 86-45 DONGAN AVE @ EXP 2 2ND & FLOOR STEEL APPX 1STORY UNDER ROOF AND NEW ROADWAY AT EXP 4 NO OVERHEAD PROTECTION FORNothing owed — awaiting certificate of correction
ECB11/17/2011WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS. SHEETING,SHORING,& BRACING NOT INSTALLED THERE IS NO SUPPORT FOR EXCAVATION @ WXPOSURE 4. "FULL STOP WORK ORDER ISSUED PURSUANTNothing owed — awaiting certificate of correction