DOB04/22/2025FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION OBSERVED BROKEN CRACKED WINDOWS IN MULTIPLE LOCATIONS AT ROOF LEVEL OBSERVED MISSING DAMAGED MOTAR JOINTS. REMEDY: REPAIR OR REPLACE
DOB10/30/2024FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION OBSERVED BROKEN/CRACKED WINDOWS IN MULTIPLE LOCATIONS AT ROOF LEVEL OBSERVED MULTIPLE STEP CRACK AND SPALLING MOTAR JOINTS AT BULKHEAD. REMEDY: REPAIR AND/OR REPLACE
DOB06/03/2024FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED BROKEN WINDOW GLASS PANE AT ALL EXPOSURES.ALSO OBSERVED DAMAGED MORTAR JOINTS AND SPALLING BRICKS.REMEDY:REPAIR AND/OR REPLACE
DOB06/03/2024EMERGENCY WORK ORDER DUE TO MULTIPLE BROKEN WINDOW PANELS AT ALL VIEW EXPOSURES.REMEDY:IMMEDIATELY MAKE REPAIRS UNDER SUPERVISION OF A NYC L IC PROFESSIONAL.REMOVE LOOSE BROKEN GLASS AND SECURE WINDOWS
ECB04/08/2025FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7C, 8C, AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #909937. AGG2: HISTORY OF NHearing held — result not yet published
ECB01/11/2023FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7C AND 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#809937.AGG2 HISTORY OF NONCOMPLINothing owed — awaiting certificate of correction
ECB11/17/2021RESTORE SERVICE TO THIS DEVICENothing owed — awaiting certificate of correction
ECB11/17/2021RESTORE SERVICE TO DEVICENothing owed — awaiting certificate of correction
ECB11/17/2021CLASS 1 ITEMS: 1)REPLACE CONTANT PRESSURE IN CAR STOP SWITCH WITH TOGGLE SWITCH OR PUSH/PULL. 20 PROVIDE PARKING DEVICE. CLASS 2 ITEMS: WORN CAR SHOES. KINK IN GOV ROPE; REPLACE. PROVIDE CONTROLLER PRINTS. LUBRNothing owed — awaiting certificate of correction
ECB11/17/2021CLASS 1 ITEMS: 1)INAUDIBLE ALARM BELL/PHONE COMBO. 2) MISSING DLM AS NOW REQUIRED BY CODE. CLASS 2 ITEMS: REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. PROVIDE HOISTWAY DOOR SIGHT GUARDS PER K3. UNGNothing owed — awaiting certificate of correction
ECB11/17/2021CLASS 1 ITEM: MISSING DLM AS NOW REQUIRED BY CODE. CLASS 2 ITEMS: SECURE TRAVELLING CABLES. MISSING TOE GUARD. REPLACE AND/OR SECURE GIBS WHERE NEEDED. OIL LEAKING ONTO TOP OF CAR. REMOVE AIR CONDITIONING UNITNothing owed — awaiting certificate of correction
ECB11/17/2021CLASS 1 ITEM: MISSING DLM AS NOW REQUIRED BY CODE CLASS 2 ITEMS: REPLACE AND/OR SECURE WORN GIBS WHERE NEEDED. REMOVE DEBRIS BLOCKING PIT DOOR. SELF RESETTING ESCAPE HATCH SWITCHES PROHIBITED. REMOVE AC UNIT FRNothing owed — awaiting certificate of correction
ECB10/28/2021CLASS 1 ITEM: MISSING DLM AS NOW REQUIRED BY CODE. CLASS 2 ITEMS: REPLACE/SECURE GIBS WHEREEVER NEEDED. PROVIDE HOISTWAY DOOR SIGHT GUARDS WHERE MISSING. DEAD BIRDS IN MACHINE ROOM ARE A HEALTH HAZARD. COMPLETENothing owed — awaiting certificate of correction
ECB10/28/2021CEASE USE ITEMS: 1) WORN BRAKE PADS; 125% BRAKE TEST REQUIRED FOR REINSPECTION. 2) DEFECTVE ZONE LOCK RESTRICTOR CLASS 1 ITEM: MISSING DLM AS NOW REQUIRED BY CODE CLASS 2 ITEMS: REPLACE AND/OR SECURE GIBS WHERENothing owed — awaiting certificate of correction
ECB05/20/2020FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7C AND 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#809937.AGG2 HISTORY OF NONCOMPLINothing owed — awaiting certificate of correction
ECB12/03/2019FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #809937. AGG1: PRIOR NOV 37009346Z UNDERNothing owed — awaiting certificate of correction
ECB04/09/2018FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#709937. AGG2 HISTORY OF NON COMPLIANCE ON 36024014LNothing owed — awaiting certificate of correction
ECB04/04/2016FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY ARTICLE 289.302 AND THE DOB RULES AND REGULATIONS.RMDY:FILNothing owed — awaiting certificate of correction
ECB04/24/2015FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28-302 & THE DEPT OF BLDGS RULES & REGULATNothing owed — awaiting certificate of correction