← Back
Factory, light manufacturing
86 NORTH 1 STREET
BROOKLYN · Williamsburg · BIN 3062586
💬 Discuss this project
1959Year Built
1Stories
F5Building Class
M1-2/R6AZoning
2,700 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Factory, light manufacturing · Owner of record: CACA LLC · 2,700 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof40p · 3 filings · 20 docs
Floor 238p · 3 filings · 20 docs
Floor 144p · 3 filings · 20 docs
Mezzanine39p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ALMA DESIGN403/22/2026
GM REALTY203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/29/2024$3.5M—— → —$1,296/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MG NEW YORK ARCHITECTS,PLLC1006/28/2024
HANSEN ENGINEERING, PC312/14/2023
BECKER ENGINEERING, P.C.204/27/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONVERSANO ASSOCIATES, INC.3003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor607/08/2026
ALMA DESIGN INCGeneral Contractor307/08/2026
GREGG NY PLUMBING, INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MG NEW YORK ARCHITECTS, P34441006/28/2024
HANSEN ENGINEERING PC8174412/14/2023
Building Lifecycle
All (107)Filed (15)Permit Issued (8)Signed Off (5)Violation (8)Inspection (9)Objection (32)Special Inspection (30)
08/19/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/28/2024
Filed — Alteration CO
filing herewith for the installation of RTU unit
B00557035-P6
05/22/2024
Filed — Alteration CO
filing herewith for the installation of RTU unit
B00557035-P5
04/04/2024
Signed off — Alteration CO
filing herewith for the installation of RTU unit
B00557035-S1
03/27/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/23/2024
Objection resolved — Addressed
01/11/2024
Objection raised — Structural
01/08/2024
Filed — Alteration CO
filing herewith for the installation of RTU unit
B00557035-P4
12/28/2023
Signed off — Alteration
Filing herewith for the installation of foundation
B00683601-I1
12/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Interior lighting power
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Fenestration areas
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Lighting controls
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Insulation placement and R values
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Air barrier - visual inspection
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
MICHAEL GADALETA
12/28/2023
Special inspection requirement — Fenestration air leakage
MICHAEL GADALETA
12/14/2023
Filed — Alteration CO
filing herewith for the installation of RTU unit
B00557035-P3
11/22/2023
Special inspection requirement — HVAC-R and service water heating equipment
Ryan Hansen
11/22/2023
Special inspection requirement — Energy Code Compliance Inspections
Ryan Hansen
11/22/2023
Special inspection requirement — Maintenance information
Ryan Hansen
11/22/2023
Special inspection requirement — Mechanical Systems
Ryan Hansen
11/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ryan Hansen
11/22/2023
Special inspection requirement — HVAC-R and service water heating system controls
Ryan Hansen
11/22/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Ryan Hansen
11/22/2023
Special inspection requirement — Final
Ryan Hansen
11/22/2023
Special inspection requirement — Duct leakage testing, insulation and design
Ryan Hansen
05/02/2023
Inspection — Pass-Final PL Permit Withdrawal
Pass
View inspection ↗
04/20/2023
Signed off — Alteration
Filing herewith for the installation of foundation
B00683601-S1
04/19/2023
Signed off — Alteration
Filing herewith for the Installation of new plumbing fixtures
B00513149-I1
04/19/2023
Signed off — Alteration
Filing herewith for the demolition and partial removal of 2nd Floor. New non-bearing wall partitions, stairs, finishes, doors and lighting
B00513042-I1
03/31/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/17/2023
Inspection — Fail-Final PL Permit Withdrawal
Fail
View inspection ↗
02/15/2023
Filed — Alteration CO
filing herewith for the installation of RTU unit
B00557035-P1
02/07/2023
Objection resolved — Addressed
01/26/2023
Objection raised — Mechanical
01/25/2023
Filed — Alteration CO
filing herewith for the installation of RTU unit
B00557035-P2
01/23/2023
Special inspection requirement — Interior lighting power
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Fenestration air leakage
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Lighting controls
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Fire-Resistance Rated Construction
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Air barrier - visual inspection
MICHAEL GADALETA
01/23/2023
Special inspection requirement — Fenestration areas
MICHAEL GADALETA
01/19/2023
Filed — Alteration
Filing herewith for the demolition and partial removal of 2nd Floor. New non-bearing wall partitions, stairs, finishes, doors and lighting
B00513042-P1
01/19/2023
Filed — Alteration
Filing herewith for the Installation of new plumbing fixtures
B00513149-P2
09/01/2022
Permit issued — Structural
B00683601-I1-ST
08/15/2022
Permit issued — Foundation
B00683601-S1-FO
08/15/2022
Permit issued — Mechanical Systems
B00557035-S1-MS
07/18/2022
Objection raised — Structural
07/18/2022
Objection resolved — Addressed
07/07/2022
Permit issued — Plumbing
B00513149-I1-PL
07/06/2022
Permit issued — General Construction
B00557035-I1-GC
05/23/2022
Permit issued — General Construction
B00513042-I1-GC
Latest 60 of 107 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offMORELL BUILDERS INC09/01/2022
DOB NOWFoundationSigned-offMORELL BUILDERS INC08/15/2022
DOB NOWMechanical SystemsSigned-offMORELL BUILDERS INC08/15/2022
DOB NOWPlumbingSigned-offGREGG NY PLUMBING, INC07/07/2022
DOB NOWGeneral ConstructionPermit IssuedMORELL BUILDERS INC07/06/2022
DOB NOWGeneral ConstructionSigned-offALMA DESIGN05/23/2022
DOB NOWGeneral ConstructionSigned-offALMA DESIGN09/06/2021
DOB NOWPlumbingSigned-offGREGG NY PLUMBING, INC05/21/2021
1 project · most recent 06/28/2024
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/28/2024Signed-offMORELL BUILDERS INCAir Conditioning Systems
Cooling
Fujitsu RGEDZR090ACA202AAA 88,000 BTU · Vrf Outdoor ×3
1 project · most recent 11/01/2023
General Wiring
FiledStatusContractorScope
11/01/2023CompleteE & M ELECTRICAL NY CORPGeneral Wiring
1 project · most recent 06/28/2024
FiledStatusContractorScope
06/28/2024Signed-offMORELL BUILDERS INC1 scope_items
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/19/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/27/2024Pass-Final CND-Occupancy InspectionPassView ↗
05/02/2023Pass-Final PL Permit WithdrawalPassView ↗
03/31/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/17/2023Fail-Final PL Permit WithdrawalFailView ↗
04/21/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/07/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/10/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/10/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 66
DateRequirementInspectorRole
12/28/2023Structural Stability – Alterations of existing buildingsMICHAEL GADALETAspecial
12/28/2023Fenestration air leakageMICHAEL GADALETAenergy_progress
12/28/2023Insulation placement and R valuesMICHAEL GADALETAenergy_progress
12/28/2023Air barrier - visual inspectionMICHAEL GADALETAenergy_progress
12/28/2023Fenestration areasMICHAEL GADALETAenergy_progress
12/28/2023Interior lighting powerMICHAEL GADALETAenergy_progress
12/28/2023Lighting controlsMICHAEL GADALETAenergy_progress
12/28/2023Fire-Resistance Rated ConstructionMICHAEL GADALETAprogress
12/28/2023Energy Code Compliance InspectionsMICHAEL GADALETAprogress
12/28/2023Fire-Resistant Penetrations and JointsMICHAEL GADALETAspecial
12/28/2023Fenestration and door U-factor and product ratingsMICHAEL GADALETAenergy_progress
11/22/2023Mechanical SystemsRyan Hansenspecial
11/22/2023Energy Code Compliance InspectionsRyan Hansenprogress
11/22/2023FinalRyan Hansenprogress
11/22/2023HVAC-R and service water heating system controlsRyan Hansenenergy_progress
11/22/2023Maintenance informationRyan Hansenenergy_progress
11/22/2023HVAC-R and service water heating equipmentRyan Hansenenergy_progress
11/22/2023Duct leakage testing, insulation and designRyan Hansenenergy_progress
11/22/2023HVAC-R and service water piping design and insulationRyan Hansenenergy_progress
11/22/2023Fire-Resistant Penetrations and JointsRyan Hansenspecial
01/23/2023Insulation placement and R valuesMICHAEL GADALETAenergy_progress
01/23/2023Fire-Resistant Penetrations and JointsMICHAEL GADALETAspecial
01/23/2023Structural Stability – Alterations of existing buildingsMICHAEL GADALETAspecial
01/23/2023Energy Code Compliance InspectionsMICHAEL GADALETAprogress
01/23/2023Fire-Resistance Rated ConstructionMICHAEL GADALETAprogress
Latest 25 of 66.
▾Documents — 132 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
09/01/2026B00513042-P1Request digital key ↗
09/01/2026B00513042-I1Request digital key ↗
08/29/2026B00683601-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Seals & Professional Certifications63
▸DOB NOWProgress Inspector Seal & Signature35
09/19/2026B00557035-P4Open ↗
09/19/2026B00557035-P4Open ↗
09/19/2026B00557035-P4Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
09/01/2026B00513042-I1Open ↗
09/01/2026B00513042-P1Open ↗
08/27/2026B00513149-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/19/2026B00557035-P4Open ↗
09/19/2026B00557035-P4Open ↗
09/01/2026B00513042-I1Open ↗
Showing 3 of 13 on file for this type
▸Safety & Tenant Protection21
▸DOB NOWHPD-1: Anti-Harassment Area Checklist15
08/13/2026B00557035-P4Open ↗
08/13/2026B00557035-P1Open ↗
08/13/2026B00557035-P3Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWStreet Tree Checklist5
08/13/2026B00557035-P6Open ↗
08/13/2026B00557035-I1Open ↗
08/13/2026B00557035-P4Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00557035-I1Open ↗
▸Environmental & Asbestos31
▸DOB NOWOER: Notice to Proceed13
08/13/2026B00513042-P1Open ↗
08/13/2026B00513149-P2Open ↗
08/13/2026B00513149-P1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report13
09/01/2026B00513042-P1Open ↗
09/01/2026B00513042-I1Open ↗
08/27/2026B00513149-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWOER: Notice of Satisfaction5
08/13/2026B00513149-I1Open ↗
08/13/2026B00683601-S1Open ↗
08/13/2026B00683601-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00557035-I1Open ↗
08/13/2026B00513042-I1Open ↗