| Owner | Filings | Most Recent |
|---|---|---|
| ALMA DESIGN | 4 | 03/22/2026 |
| GM REALTY | 2 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/29/2024 | $3.5M | — | — → — | $1,296/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| MG NEW YORK ARCHITECTS,PLLC | 10 | 06/28/2024 |
| HANSEN ENGINEERING, PC | 3 | 12/14/2023 |
| BECKER ENGINEERING, P.C. | 2 | 04/27/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| CONVERSANO ASSOCIATES, INC. | 30 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MORELL BUILDERS INC | General Contractor | 6 | 07/08/2026 |
| ALMA DESIGN INC | General Contractor | 3 | 07/08/2026 |
| GREGG NY PLUMBING, INC | Plumbing | 2 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| MG NEW YORK ARCHITECTS, P | 3444 | 10 | 06/28/2024 |
| HANSEN ENGINEERING PC | 8174 | 4 | 12/14/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | MORELL BUILDERS INC | 09/01/2022 |
| DOB NOW | Foundation | Signed-off | MORELL BUILDERS INC | 08/15/2022 |
| DOB NOW | Mechanical Systems | Signed-off | MORELL BUILDERS INC | 08/15/2022 |
| DOB NOW | Plumbing | Signed-off | GREGG NY PLUMBING, INC | 07/07/2022 |
| DOB NOW | General Construction | Permit Issued | MORELL BUILDERS INC | 07/06/2022 |
| DOB NOW | General Construction | Signed-off | ALMA DESIGN | 05/23/2022 |
| DOB NOW | General Construction | Signed-off | ALMA DESIGN | 09/06/2021 |
| DOB NOW | Plumbing | Signed-off | GREGG NY PLUMBING, INC | 05/21/2021 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/28/2024 | Signed-off | MORELL BUILDERS INC | Air Conditioning Systems | Cooling Fujitsu RGEDZR090ACA202AAA 88,000 BTU · Vrf Outdoor ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 11/01/2023 | Complete | E & M ELECTRICAL NY CORP | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/28/2024 | Signed-off | MORELL BUILDERS INC | 1 scope_items |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/19/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/27/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/02/2023 | Pass-Final PL Permit Withdrawal | Pass | View ↗ |
| 03/31/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 03/17/2023 | Fail-Final PL Permit Withdrawal | Fail | View ↗ |
| 04/21/2022 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 10/07/2021 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/10/2021 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 06/10/2021 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/28/2023 | Structural Stability – Alterations of existing buildings | MICHAEL GADALETA | special |
| 12/28/2023 | Fenestration air leakage | MICHAEL GADALETA | energy_progress |
| 12/28/2023 | Insulation placement and R values | MICHAEL GADALETA | energy_progress |
| 12/28/2023 | Air barrier - visual inspection | MICHAEL GADALETA | energy_progress |
| 12/28/2023 | Fenestration areas | MICHAEL GADALETA | energy_progress |
| 12/28/2023 | Interior lighting power | MICHAEL GADALETA | energy_progress |
| 12/28/2023 | Lighting controls | MICHAEL GADALETA | energy_progress |
| 12/28/2023 | Fire-Resistance Rated Construction | MICHAEL GADALETA | progress |
| 12/28/2023 | Energy Code Compliance Inspections | MICHAEL GADALETA | progress |
| 12/28/2023 | Fire-Resistant Penetrations and Joints | MICHAEL GADALETA | special |
| 12/28/2023 | Fenestration and door U-factor and product ratings | MICHAEL GADALETA | energy_progress |
| 11/22/2023 | Mechanical Systems | Ryan Hansen | special |
| 11/22/2023 | Energy Code Compliance Inspections | Ryan Hansen | progress |
| 11/22/2023 | Final | Ryan Hansen | progress |
| 11/22/2023 | HVAC-R and service water heating system controls | Ryan Hansen | energy_progress |
| 11/22/2023 | Maintenance information | Ryan Hansen | energy_progress |
| 11/22/2023 | HVAC-R and service water heating equipment | Ryan Hansen | energy_progress |
| 11/22/2023 | Duct leakage testing, insulation and design | Ryan Hansen | energy_progress |
| 11/22/2023 | HVAC-R and service water piping design and insulation | Ryan Hansen | energy_progress |
| 11/22/2023 | Fire-Resistant Penetrations and Joints | Ryan Hansen | special |
| 01/23/2023 | Insulation placement and R values | MICHAEL GADALETA | energy_progress |
| 01/23/2023 | Fire-Resistant Penetrations and Joints | MICHAEL GADALETA | special |
| 01/23/2023 | Structural Stability – Alterations of existing buildings | MICHAEL GADALETA | special |
| 01/23/2023 | Energy Code Compliance Inspections | MICHAEL GADALETA | progress |
| 01/23/2023 | Fire-Resistance Rated Construction | MICHAEL GADALETA | progress |