← Back
Multi-story retail building (2+)
8610 BAY PARKWAY
BROOKLYN · BIN 3167070
💬 Discuss this project
1931Year Built
2Stories
K2Building Class
C4-2Zoning
2,560 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Multi-story retail building (2+) · Owner of record: 8610 BAY LLC · 1,363 sf lot · 1.88 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 5 docs
Floor 22p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Cellar2p · 2 filings · 14 docs
1 job · most recent 09/29/2020
FiledStatusContractorScope
09/29/2020Permit IssuedKJK ELECTRIC INC1 meters
Building Lifecycle
All (51)Filed (11)Permit Issued (5)Signed Off (5)Violation (6)Inspection (5)Special Inspection (19)
03/06/2025
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH THE RENOVATION OF AN EXISTING COMMERCIAL SPACE. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01096104-I1
03/05/2025
Signed off — Alteration
RENOVATION OF AN EXISTING COMMERCIAL SPACE. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01095305-I1
03/04/2025
Signed off — Alteration
MINOR MODIFICATIONS & ADDITIONS TO PLUMBING FIXTURES. PIPING & APPLIANCES (CEL.-ROF).. FILE HEREWITH ARE PLANS. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01095306-I1
02/18/2025
Signed off — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-S1
02/12/2025
Signed off — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-I1
02/12/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
02/03/2025
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
02/03/2025
Special inspection requirement — Final
FAZAL BANGASH
02/03/2025
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
02/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
02/01/2025
Filed — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-P2
02/01/2025
Filed — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-P3
01/31/2025
Permit issued — General Construction
B01111953-I1-GC
01/30/2025
Filed — Alteration
MINOR MODIFICATIONS & ADDITIONS TO PLUMBING FIXTURES. PIPING & APPLIANCES (CEL.-ROF).. FILE HEREWITH ARE PLANS. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01095306-P2
01/30/2025
Special inspection requirement — Final
FAZAL BANGASH
01/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
01/30/2025
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
01/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
01/30/2025
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
12/04/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/04/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/26/2024
Filed — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-P1
10/30/2024
Permit issued — General Construction
B01111953-I1-GC
10/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
10/29/2024
Special inspection requirement — Energy Code Compliance Inspections
FAZAL BANGASH
10/18/2024
Filed — Alteration
MINOR MODIFICATIONS & ADDITIONS TO PLUMBING FIXTURES. PIPING & APPLIANCES (CEL.-ROF).. FILE HEREWITH ARE PLANS. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01095306-P1
10/08/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/03/2024
Permit issued — Plumbing
B01111953-S1-PL
10/01/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/27/2024
Filed — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-S1
09/27/2024
Filed — Alteration
FILE PLUMBING WORK IN NAIL STORE WITH INSTALLATION OF NEW PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01111953-I1
09/24/2024
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH THE RENOVATION OF AN EXISTING COMMERCIAL SPACE. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01096104-P1
09/24/2024
Special inspection requirement — Final
Lisa Vangelas
09/24/2024
Special inspection requirement — HVAC-R and service water heating system controls
Lisa Vangelas
09/24/2024
Special inspection requirement — HVAC-R and service water heating equipment
Lisa Vangelas
09/24/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Lisa Vangelas
09/24/2024
Special inspection requirement — Mechanical Systems
Lisa Vangelas
08/29/2024
Permit issued — Plumbing
B01095306-I1-PL
08/27/2024
Permit issued — General Construction
B01095305-I1-GC
08/19/2024
Filed — Alteration
MECHANICAL WORK ASSOCIATED WITH THE RENOVATION OF AN EXISTING COMMERCIAL SPACE. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01096104-I1
08/14/2024
Filed — Alteration
RENOVATION OF AN EXISTING COMMERCIAL SPACE. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01095305-I1
08/14/2024
Filed — Alteration
MINOR MODIFICATIONS & ADDITIONS TO PLUMBING FIXTURES. PIPING & APPLIANCES (CEL.-ROF).. FILE HEREWITH ARE PLANS. NO CHANGE IN USE EGRESS OR OCCUPANCY.
B01095306-I1
08/13/2024
Special inspection requirement — Final
Lisa Vangelas
08/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Lisa Vangelas
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
8610 BAY2507/08/2026
GMD PROPERTIES307/08/2026
8610 RLTY403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/16/2020$2.0M—Private party → 8610 BAY LLC$781/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BANGASH ASSOCIATES INC.502/01/2025
LINEA LLP601/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC BUILDING CONSULTANTS503/21/2026
SOL BUILDING CONSULTING SERVICES603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LT PRO CONSTRUCTION INCGeneral Contractor407/08/2026
RITE-WAY RENOVATORS INCGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
SUPERIOR PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BANGASH ASSOCIATES INC8488502/01/2025
LINEA LLP3155309/24/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offLT PRO CONSTRUCTION INC01/31/2025
DOB NOWGeneral ConstructionSigned-offLT PRO CONSTRUCTION INC10/30/2024
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.10/03/2024
DOB NOWPlumbingSigned-offSUPERIOR PLUMBING & HEATI08/29/2024
DOB NOWGeneral ConstructionSigned-offRITE-WAY RENOVATORS INC08/27/2024
BISPLISSUEDCOOPER MECHANICAL CORP12/29/2004
BISEQISSUEDNORDWAY CORP12/02/2003
BIS—ISSUEDNORDWAY CORP.09/17/2002
BISEQISSUEDNORDWAY CORP04/30/2002
BISPLISSUEDWADE PLBG & HTG08/24/2001
BIS—ISSUEDNORDWAY CORP.08/17/2001
BISEQISSUEDNORDWAY CORP07/26/2001
BISEQISSUEDR&RCONSTRUCTIONOFTHETRI-STATEINC10/23/1995
BISOTISSUEDR&RCONSTRUCTIONOFTHETRI-STATEINC10/23/1995
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/12/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/04/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/04/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/08/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
10/01/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
02/03/2025Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
02/03/2025Energy Code Compliance InspectionsFAZAL BANGASHprogress
02/03/2025FinalFAZAL BANGASHprogress
02/03/2025Energy Code Compliance InspectionsFAZAL BANGASHprogress
02/03/2025Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
01/30/2025FinalFAZAL BANGASHprogress
01/30/2025Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
01/30/2025Energy Code Compliance InspectionsFAZAL BANGASHprogress
01/30/2025Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
01/30/2025Energy Code Compliance InspectionsFAZAL BANGASHprogress
10/29/2024Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
10/29/2024Energy Code Compliance InspectionsFAZAL BANGASHprogress
09/24/2024FinalLisa Vangelasprogress
09/24/2024HVAC-R and service water heating system controlsLisa Vangelasenergy_progress
09/24/2024HVAC-R and service water heating equipmentLisa Vangelasenergy_progress
09/24/2024HVAC-R and service water piping design and insulationLisa Vangelasenergy_progress
09/24/2024Mechanical SystemsLisa Vangelasspecial
08/13/2024FinalLisa Vangelasprogress
08/13/2024Fire-Resistant Penetrations and JointsLisa Vangelasspecial
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/24/2026B01095305-I1Request digital key ↗
08/24/2026B01095306-P2Request digital key ↗
08/24/2026B01095306-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications26
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/24/2026B01095306-I1Open ↗
08/24/2026B01095306-P1Open ↗
08/24/2026B01095306-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/21/2026B01096104-I1Open ↗
09/21/2026B01096104-I1Open ↗
09/02/2026B01111953-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/21/2026B01096104-I1Open ↗
09/02/2026B01111953-S1Open ↗
09/01/2026B01111953-I1Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/24/2026B01095306-P1Open ↗
08/24/2026B01095306-P2Open ↗
08/24/2026B01095306-I1Open ↗
Showing 3 of 11 on file for this type