← Back
Two family brick
87-15 63RD AVENUE
QUEENS · BIN 4617346
💬 Discuss this project
2002Year Built
2.67Stories
B1Building Class
R4Zoning
2,530 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family brick · 2,320 sf lot · 1.09 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivil
Roof12p · 2 filings · 20 docs
Floor 424p · 2 filings · 20 docs
Floor 325p · 2 filings · 20 docs
Floor 224p · 2 filings · 20 docs
Floor 124p · 2 filings · 20 docs
Cellar18p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AVENTADOR CONSTRUCTION IN503/22/2026
IN AVENTADOR CONSTRUCTION103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FABIAN CRUZ PE PLLC308/16/2024
GERALD CALIENDO ARCHITECTS206/13/2023
RAS PE CONSULTING ENGINEERS305/12/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GERALD J. CALIENDO R.A., P.C.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AVENTADOR CONSTRUCTION INGeneral Contractor1107/08/2026
AMERICAN STANDARD PLUMBING &Fire Protection107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DOYUN KIM; RA7415608/16/2024
MARKANICS CORP4600105/12/2023
Building Lifecycle
All (52)Filed (8)Permit Issued (9)Violation (6)Inspection (5)Objection (14)Special Inspection (10)
06/02/2026
Permit issued — Construction Fence
Q00889522-I1-FN
03/04/2026
Violation issued (ECB, closed)
Construction
03/04/2026
Violation issued (ECB, closed)
Unknown
03/04/2026
Violation issued (ECB, closed)
Construction
06/03/2025
Violation issued (ECB, closed)
Unknown
05/29/2025
Permit issued — Construction Fence
Q00889522-I1-FN
12/24/2024
Violation issued (ECB, closed)
Unknown
11/01/2024
Objection raised — Admin
11/01/2024
Objection resolved — Addressed
10/29/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/20/2024
Permit issued — Construction Fence
Q00889522-I1-FN
08/20/2024
Special inspection requirement — Sprinkler Systems
DOYUN KIM
08/16/2024
Filed — Alteration
INSTALLATION OF PLUMBING AND SPRINKLER SYSTEM FOR 4 STORY RESIDENTIAL BUILDING IN CONJUNCTION WITH NB#421755014
Q00864188-P1
06/13/2024
Permit issued — Plumbing
Q00864188-I1-PL
06/13/2024
Permit issued — Plumbing
Q00864188-I1-EW-SP
01/16/2024
Violation issued (ECB, closed)
Unknown
10/23/2023
Permit issued — Earth Work
Q00872712-S1-FO-EA
09/22/2023
Permit issued — Support of Excavation
Q00872712-S2-SE
09/12/2023
Permit issued — Construction Fence
Q00889522-I1-FN
08/31/2023
Permit issued — Structural
Q00872712-I1-ST
08/04/2023
Objection raised — Fire_Protection
08/04/2023
Objection resolved — Addressed
07/11/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/15/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/13/2023
Filed — Alteration
Q00889522-I1
06/09/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
06/06/2023
Objection resolved — Addressed
06/06/2023
Objection resolved — Addressed
05/18/2023
Objection raised — Admin
05/18/2023
Objection raised — Cost
05/12/2023
Filed — Alteration
Herewith filing for Structural plans of 4-Story NB filed under job# Q00872712-I1 in conjunction to DOB job# 421755014.
Q00872712-S2
05/12/2023
Filed — Alteration
Herewith filing for Structural plans of 4-Story NB filed under job# Q00872712-I1 in conjunction to DOB job# 421755014.
Q00872712-I1
05/12/2023
Filed — Alteration
Herewith filing for Structural plans of 4-Story NB filed under job# Q00872712-I1 in conjunction to DOB job# 421755014.
Q00872712-S1
05/10/2023
Special inspection requirement — Footing and Foundation
DOYUN KIM
05/10/2023
Special inspection requirement — Final
JEFFREY BELL
05/10/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
DOYUN KIM
05/10/2023
Special inspection requirement — Concrete - Cast-In-Place
DOYUN KIM
05/10/2023
Special inspection requirement — Underpinning
Malcolm Barkan
05/10/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
ROBERT DYKSTRA
05/10/2023
Special inspection requirement — Subgrade Inspections
DOYUN KIM
05/09/2023
Objection raised — Mechanical
05/09/2023
Objection resolved — Addressed
05/09/2023
Objection raised — Scope
05/09/2023
Objection resolved — Addressed
05/09/2023
Objection raised — Other
05/09/2023
Objection resolved — Addressed
05/03/2023
Filed — Alteration
INSTALLATION OF MECHANICAL SYSTEM FOR 4 FAMILY RESIDENTIAL BUILDING IN CONJUNCTION WITH NB#421755014
Q00864209-I1
05/03/2023
Filed — Alteration
INSTALLATION OF PLUMBING AND SPRINKLER SYSTEM FOR 4 STORY RESIDENTIAL BUILDING IN CONJUNCTION WITH NB#421755014
Q00864188-I1
04/24/2023
Special inspection requirement — Final
JEFFREY BELL
04/24/2023
Special inspection requirement — Mechanical Systems
DOYUN KIM
12/21/2022
Filed — Alteration
Herewith filing Curb Cut in conjunction with New Building Application 421755014. Total width including splays is 10'-0", 7'-0" fronting subject property
Q08047147-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedAVENTADOR CONSTRUCTION IN06/02/2026
DOB NOWConstruction FencePermit IssuedAVENTADOR CONSTRUCTION IN05/29/2025
DOB NOWConstruction FencePermit IssuedAVENTADOR CONSTRUCTION IN09/20/2024
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.06/13/2024
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD PLUMBIN06/13/2024
DOB NOWEarth WorkPermit IssuedAVENTADOR CONSTRUCTION IN10/23/2023
DOB NOWSupport of ExcavationPermit IssuedAVENTADOR CONSTRUCTION IN09/22/2023
DOB NOWConstruction FencePermit IssuedAVENTADOR CONSTRUCTION IN09/12/2023
DOB NOWStructuralPermit IssuedAVENTADOR CONSTRUCTION IN08/31/2023
BIS—ISSUEDAVENTADOR CONSTRUCTION IN05/31/2024
BIS—ISSUEDAVENTADOR CONSTRUCTION IN01/22/2024
1 project · most recent 05/03/2023
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/03/2023——Heating Systems, Ventilation Systems
Heating
Burnham SERIES 2 103,000 BTU · Boiler ×4
Ventilation
Greenheck GB SERIES VARI-GREEN 425 CFM · Exhaust Fan ×2
1 project · most recent 08/16/2024
FiledStatusContractorScope
08/16/2024Permit IssuedAMERICAN STANDARD PLUMBIN32 heads
1 project · most recent 08/16/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/16/2024Permit IssuedAMERICAN STANDARD P&H CORGas, Storm, Water/Sanitary
1 project · most recent 06/26/2024
General Wiring
FiledStatusContractorScope
06/26/2024Permit IssuedERIC & NG ELEC'L, INC.General Wiring
2 projects · most recent 05/12/2023
Steel Concrete Masonry
FiledStatusContractorScope
05/12/2023Permit IssuedAVENTADOR CONSTRUCTION INSteel, Concrete, Masonry
12/21/2022——1 scope_items
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/29/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/29/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/11/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/15/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/09/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/20/2024Sprinkler SystemsDOYUN KIMspecial
05/10/2023Footing and FoundationDOYUN KIMprogress
05/10/2023FinalJEFFREY BELLprogress
05/10/2023Excavations - Sheeting, Shoring, and BracingDOYUN KIMspecial
05/10/2023Concrete - Cast-In-PlaceDOYUN KIMspecial
05/10/2023UnderpinningMalcolm Barkanspecial
05/10/2023Subsurface Investigations (Borings/Test Pits)ROBERT DYKSTRAspecial
05/10/2023Subgrade InspectionsDOYUN KIMspecial
04/24/2023FinalJEFFREY BELLprogress
04/24/2023Mechanical SystemsDOYUN KIMspecial
▾Documents — 122 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/25/2026Q08047147-I1Request digital key ↗
08/24/2026Q00872712-S2Request digital key ↗
08/24/2026Q00872712-P2Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits14
▸BISPLAN / WORK APPROVAL APPLICATION11
03/07/2023421755014Open ↗
03/07/2023421755014Open ↗
03/03/2023421755014Open ↗
Showing 3 of 11 on file for this type
▸BISWORK PERMIT APPLICATION3
07/14/2025421755014Open ↗
01/22/2024421755014Open ↗
10/10/2023421755014Open ↗
▸Zoning, Tax Lot & Property Records8
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED2
04/12/2023440758253Open ↗
04/12/2022421755014Open ↗
▸BISTAX LOT: FINAL LOT NUMBER ISSUED2
09/20/2017421553900Open ↗
03/02/2020421755014Open ↗
▸BISZoning Resolution Determination1
04/12/2022421755014Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
09/20/2017421553900Open ↗
▸BISZONING DIAGRAM1
03/22/2023421755014Open ↗
▸BISZoning Exhibit Iii Desc Amp Ownrshp Stmnt1
03/06/2023421755014Open ↗
▸Seals & Professional Certifications36
▸DOB NOWSpecial Inspector Seal & Signature17
09/18/2026Q00872712-P1Open ↗
09/18/2026Q00872712-P1Open ↗
09/18/2026Q00872712-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/24/2026Q00872712-S2Open ↗
08/24/2026Q00872712-P2Open ↗
08/24/2026Q00872712-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/18/2026Q00872712-P1Open ↗
08/27/2026Q00872712-S1Open ↗
08/27/2026Q00872712-S1Open ↗
Showing 3 of 6 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/29/2022440758253Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/29/2022440758253Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/20/2017421553900Open ↗
▸Trade Schedules & Equipment1
▸BISSewer Connection Dep Sd1 Amp Sd21
03/06/2023421755014Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST4
04/12/2023440758253Open ↗
03/06/2023421755014Open ↗
03/04/2020421755014Open ↗
Showing 3 of 4 on file for this type
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
08/02/2023421755014Open ↗
▸BISBPP: STREET TREES SITE PLAN1
04/12/2023440758253Open ↗
▸BISSTREET TREES SITE PLAN1
03/06/2023421755014Open ↗
▸Energy Compliance6
▸BISTechnical Report Energy Code Progress Insps3
10/10/2023421755014Open ↗
03/04/2020421755014Open ↗
09/20/2017421553900Open ↗
▸BISTechnical Report Energy Code Responsibility2
08/02/2023421755014Open ↗
03/01/2023421755014Open ↗
▸BISTr8 Energy Code Progress Insps Technical Report1
03/06/2023421755014Open ↗
▸Inspections & Test Reports17
▸BISTechnical Report Responsibility Certification3
12/10/2025421755014Open ↗
10/10/2023421755014Open ↗
03/04/2020421755014Open ↗
▸BISTechnical Report Responsibility3
12/28/2023421755014Open ↗
08/02/2023421755014Open ↗
03/06/2023421755014Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION2
12/10/2025421755014Open ↗
04/28/2025421755014Open ↗
▸DOB NOWSOIL REPORT2
08/13/2026Q00872712-P2Open ↗
08/13/2026Q00872712-S1Open ↗
▸BISSOIL REPORT1
03/06/2023421755014Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
12/10/2025421755014Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
04/28/2025421755014Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
01/22/2024421755014Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
03/06/2023421755014Open ↗
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT1
01/22/2024421755014Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00872712-S1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISSCHEDULE A - OCCUPANCY / USE3
03/07/2023421755014Open ↗
03/04/2020421755014Open ↗
09/20/2017421553900Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
09/06/2022421755014Open ↗
▸Cost, Insurance & Ownership2
▸BISProject Specific General Liability Insurance1
10/10/2023421755014Open ↗
▸BISProject Specific Gl Insurance1
12/10/2025421755014Open ↗
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION3
04/12/2023440758253Open ↗
03/22/2023421755014Open ↗
11/21/2022421755014Open ↗
▸BISBOROUGH INTAKE FORM2
07/16/2025421755014Open ↗
10/10/2023421755014Open ↗
▸BISEFILING COVER SHEET2
03/04/2020421755014Open ↗
09/20/2017421553900Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/29/2022440758253Open ↗
▸Other Documents9
▸BISPLOT DIAGRAM3
04/12/2022421755014Open ↗
03/02/2020421755014Open ↗
09/20/2017421553900Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026Q00872712-S2Open ↗
08/13/2026Q00872712-S1Open ↗
▸BISSustainable Roof Zone Form1
11/21/2022421755014Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
04/13/2023440758253Open ↗
▸BISCURB CUT: PROVIDE EXISTING NUMBER1
04/12/2023440758253Open ↗
▸BISSupporting Document: Fee Deferment1
09/02/2022421755014Open ↗