← Back
Two family frame
87-16 88 STREET
QUEENS · Woodhaven · BIN 4184008
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R3-1Zoning
1,944 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 1,925 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/20/2016$660K—Private party → Private party$340/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALPHA HOME DESIGN LLC310/23/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
INDESIGN STUDIO603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAFETY PRO CONSTRUCTIONGeneral Contractor303/21/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YAN GAO6619310/23/2023
Building Lifecycle
All (22)Filed (3)Permit Issued (2)Signed Off (2)Violation (6)Inspection (5)Special Inspection (4)
07/05/2024
Violation issued (ECB, closed)
Construction
11/08/2023
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING 2-FAMILY BUILDING WORK AT CELLAR, AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00936452-I1
11/06/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/02/2023
Signed off — Alteration
Q00936479-I1
11/02/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
10/25/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/23/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 2-FAMILY BUILDING WORK AT CELLAR, AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00936452-P1
10/23/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
YAN GAO
10/23/2023
Special inspection requirement — Energy Code Compliance Inspections
YAN GAO
10/23/2023
Special inspection requirement — Fire-Resistance Rated Construction
YAN GAO
10/23/2023
Special inspection requirement — Interior lighting power
YAN GAO
10/20/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/17/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/28/2023
Permit issued — Plumbing
Q00936479-I1-PL
09/28/2023
Permit issued — General Construction
Q00936452-I1-GC
09/20/2023
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 2-FAMILY BUILDING WORK AT CELLAR, AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00936452-I1
09/20/2023
Filed — Alteration
Q00936479-I1
08/17/2023
Violation issued (HPD, closed)
B
08/17/2023
Violation issued (HPD, closed)
B
08/17/2023
Violation issued (HPD, closed)
B
06/03/2016
Violation issued (ECB, closed)
Construction
08/30/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.09/28/2023
DOB NOWGeneral ConstructionSigned-offSAFETY PRO CONSTRUCTION09/28/2023
BISOTISSUEDNOVA VASQUEZ & ASSOCIATES08/14/2015
BISOTISSUEDA.D. EXCAVATING &CONST. CORP.09/14/2000
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/06/2023Pass-Final General Construction Non-Directive 14PassView ↗
11/02/2023Fail-Final General Construction Non-Directive 14FailView ↗
10/25/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/20/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/17/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
10/23/2023Fire-Resistant Penetrations and JointsYAN GAOspecial
10/23/2023Energy Code Compliance InspectionsYAN GAOprogress
10/23/2023Fire-Resistance Rated ConstructionYAN GAOprogress
10/23/2023Interior lighting powerYAN GAOenergy_progress
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00936452-I1Request digital key ↗
08/24/2026Q00936452-P1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
01/27/2017401130263Open ↗
08/10/2015421196887Open ↗
▸BISApplication Withdrawal/Address Change Form OP-1131
01/27/2017401130263Open ↗
▸BISWORK PERMIT APPLICATION1
08/20/2015421196887Open ↗
▸Seals & Professional Certifications10
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
03/18/2016421196887Open ↗
08/20/2015421196887Open ↗
08/10/2015421196887Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00936452-I1Open ↗
08/24/2026Q00936452-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026Q00936452-P1Open ↗
08/24/2026Q00936452-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/10/2015421196887Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/10/2015421196887Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026Q00936452-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026Q00936452-I1Open ↗
08/24/2026Q00936452-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/10/2015421196887Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
08/20/2015421196887Open ↗
08/10/2015421196887Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/18/2016421196887Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION3
03/18/2016421196887Open ↗
03/18/2016421196887Open ↗
03/18/2016421196887Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/18/2016421196887Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/18/2016421196887Open ↗
08/10/2015421196887Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
08/10/2015421196887Open ↗