ECB12/18/2023FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-02038, DATED 7/13/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/20$12K due
DOB07/13/2023FAILURE TO MAINTAIN. OBSERVED DANGEROUS CONDITION, DUE TO A NEWLY ERECTED BRICK PARAPET WALL AT EXPOSURE#1, ABOVE THE ENTRANCE DOOR
DOB07/13/2023FAILURE TO MAINTAIN. OBSERVED AT EXPOSURE#1, A NEWLY ERECTED BRICK PARAPET WALL ON THE SECOND FLOOR
ECB08/23/2017WORK W/O A PERMIT. WORK NOTED: AT REAR OF PREMISE REMOVED GARAGE DOOR AND DID CONSTRUCTION WORK TO CLOSE OPENING AND INSTALL 2 METAL DOORS WITH LOCKING DEVICE.ALSO ENLARGED GARAGE APPRX 5X15. AT 2ND FLR OF PREMNothing owed — awaiting certificate of correction
ECB04/07/2009WORK WITHOUT A PERMIT- REAR EXTENSION WITH BRICK AT FIRST AND 2ND FLOOR IS APPROX 16' DEEP X 20' HIGH AND BUTTS GARAGE AT REAR YARD. DONE WITH NO PERMIT AND NO STRUCTURAL STABILITY ATTESTED TO. REM: OBTAIN PERMNothing owed — awaiting certificate of correction
ECB04/07/2009APPROX 16' DEEP BRICK EXTENSION AT REAR OF DWELLING EXTENDS IN THE REQUIRED REAR YARD. REM: OBTAIN PERMIT AND REMOVE ILLEGAL STRUCTURE IMMEDIATELY,Nothing owed — awaiting certificate of correction
ECB04/07/2009APPROX: 16' DEEP X 20' HIGH BRICK. EXTENSION AT REAR HAS BEEN EXTENDED IN REQUIRED 8' SIDE YARD AT SOUTH EXPOSURE. REM: OBTAIN A PERMIT AND REMOVE ILLEGAL STRUCTURE IMMEDIATELY-Nothing owed — awaiting certificate of correction
ECB04/07/2009WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS. NON-CONFORMING WORK NOTED: 1-PLAN SHOWS FRONT YARD TO BE 2' FOUND FRONT YARD TO BE 5' 2-PLANS SHOW REAR STEEL DECK AT 2ND FLOOR LEVELNothing owed — awaiting certificate of correction