← Back
Three families
87 WAVERLY AVENUE
BROOKLYN · BIN 3054357
💬 Discuss this project
1901Year Built
3Stories
C0Building Class
R6BZoning
2,296 sfGross Floor Area
3Units
Rent Stabilized127 Open Violations 126 unresolved · 1 paperwork only ▸FDNY Report ↗
Three families · 1,900 sf lot · 1.21 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Roof3p · 1 filing · 16 docs
Floor 33p · 1 filing · 16 docs
Floor 2
Floor 11p · 1 filing · 20 docs
Cellar3p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SKY ELECTRIC LLC103/22/2026
H.W CONSTRUCTION & ASSOC2003/22/2026
H.W. CONSTRUCTION 4 ASSOC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/07/2025$1.9M—— → —$828/sf building
11/29/2023$1.5M—— → —$662/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FORMACTIV508/05/2026
BHK ENGINEERING209/30/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PANTOCRAFT1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPECTRA CONSTR & DEV CORPGeneral Contractor1307/08/2026
M & M PIPING AND HEATINGPlumbing206/28/2026
JOSEPH WEINSTEIN ELECTRICElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FORMACTIV ARCHITECTURE3024508/05/2026
BHK ENGINEERING, D.P.C.9589209/30/2025
Building Lifecycle
All (129)Filed (7)Permit Issued (11)Signed Off (4)Violation (60)Inspection (11)Objection (6)Special Inspection (30)
08/25/2026
Signed off — Alteration
Subsequent Plumbing for 2nd and 3rd floor residential units as per plans filed. No change to use, egress, or occupancy under this applicaiton.
B01194010-I1
08/18/2026
Signed off — Alteration
Subsequent minor Structural work at Cellar / 1st Fl duplex residential apartment as per plans filed herewith. No change to use, egress, or occupancy.
B01206045-I1
08/14/2026
Signed off — Alteration
Subsequent Plumbing for 2nd and 3rd floor residential units as per plans filed. No change to use, egress, or occupancy under this applicaiton.
B01194010-S2
08/14/2026
Signed off — Alteration
Subsequent minor Structural work at Cellar / 1st Fl duplex residential apartment as per plans filed herewith. No change to use, egress, or occupancy.
B01206045-S2
08/05/2026
Filed — Alteration
Subsequent minor Structural work at Cellar / 1st Fl duplex residential apartment as per plans filed herewith. No change to use, egress, or occupancy.
B01206045-P1
08/05/2026
Special inspection requirement — Energy Code Compliance Inspections
Ron Eng
08/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ron Eng
08/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Ron Eng
08/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ron Eng
08/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Ron Eng
08/04/2026
Special inspection requirement — Energy Code Compliance Inspections
Ron Eng
07/22/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/12/2026
Permit issued — Mechanical Systems
B01194010-I1-MS
05/12/2026
Permit issued — Mechanical Systems
B01206045-I1-GC
05/06/2026
Violation issued (HPD, open)
A
05/01/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/01/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/10/2026
Permit issued — Mechanical Systems
B01194010-I1-GC
03/26/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/25/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
03/11/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/26/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/17/2025
Violation issued (ECB, closed)
Unknown
12/16/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/03/2025
Permit issued — Structural
B01206045-S2-ST
10/03/2025
Permit issued — Mechanical Systems
B01206045-I1-MS
10/02/2025
Permit issued — Structural
B01194010-S2-ST
09/30/2025
Filed — Alteration
Subsequent Plumbing for 2nd and 3rd floor residential units as per plans filed. No change to use, egress, or occupancy under this applicaiton.
B01194010-S2
09/30/2025
Filed — Alteration
Subsequent minor Structural work at Cellar / 1st Fl duplex residential apartment as per plans filed herewith. No change to use, egress, or occupancy.
B01206045-S2
09/29/2025
Special inspection requirement — Structural Steel - Details
William DeGraaff
09/29/2025
Special inspection requirement — Structural Steel - Details
William DeGraaff
09/29/2025
Special inspection requirement — Structural Steel - Welding
William DeGraaff
09/29/2025
Special inspection requirement — Structural Steel - High Strength Bolting
William DeGraaff
09/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
William DeGraaff
09/29/2025
Special inspection requirement — Post-installed Anchors
William DeGraaff
09/29/2025
Special inspection requirement — Structural Steel - High Strength Bolting
William DeGraaff
09/29/2025
Special inspection requirement — Post-installed Anchors
William DeGraaff
09/29/2025
Special inspection requirement — Concrete - Cast-In-Place
William DeGraaff
09/29/2025
Special inspection requirement — Structural Steel - Welding
William DeGraaff
09/25/2025
Special inspection requirement — Final
William DeGraaff
09/25/2025
Special inspection requirement — Final
William DeGraaff
09/25/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
William DeGraaff
09/24/2025
Violation issued (ECB, open)
Construction
09/24/2025
Violation issued (ECB, open)
Construction
09/24/2025
Violation issued (ECB, open)
Construction
09/23/2025
Permit issued — Plumbing
B01194010-S1-PL
09/22/2025
Permit issued — Plumbing
B01206045-S1-PL
06/11/2025
Violation issued (HPD, open)
A
05/15/2025
Permit issued — Mechanical Systems
B01206045-I1-GC
04/28/2025
Objection resolved — Addressed
04/28/2025
Objection resolved — Addressed
04/28/2025
Objection resolved — Addressed
04/22/2025
Objection raised — Other
04/22/2025
Objection raised — Scope
04/22/2025
Objection raised — Plumbing
04/10/2025
Filed — Alteration
Subsequent minor Structural work at Cellar / 1st Fl duplex residential apartment as per plans filed herewith. No change to use, egress, or occupancy.
B01206045-I1
04/10/2025
Filed — Alteration
Subsequent minor Structural work at Cellar / 1st Fl duplex residential apartment as per plans filed herewith. No change to use, egress, or occupancy.
B01206045-S1
Latest 60 of 129 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP05/12/2026
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP05/12/2026
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP04/10/2026
DOB NOWStructuralSigned-offSPECTRA CONSTR & DEV CORP10/03/2025
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP10/03/2025
DOB NOWStructuralSigned-offSPECTRA CONSTR & DEV CORP10/02/2025
DOB NOWPlumbingSigned-offM & M PIPING AND HEATING09/23/2025
DOB NOWPlumbingSigned-offM & M PIPING AND HEATING09/22/2025
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP05/15/2025
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP04/10/2025
DOB NOWMechanical SystemsSigned-offSPECTRA CONSTR & DEV CORP04/04/2025
2 jobs · most recent 08/05/2026
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/05/2026Signed-offSPECTRA CONSTR & DEV CORPAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric MY-GS12NA-U1 12,000 BTU · Fan Coil Indoor ×2
MXZ-SM42NAMHZ 42,000 BTU · Heat Pump Outdoor ×1
MY-GS18NA-U1 18,000 BTU · Fan Coil Indoor ×1
Ventilation
Broan NA 300 CFM · Exhaust Fan ×2
Mitsubishi Electric MXZ-SM42NAMHZ 42,000 BTU · Condensing Unit ×1
09/30/2025Signed-offSPECTRA CONSTR & DEV CORPAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric MY-GS09NA-U1 8,000 BTU · Ahu ×2
MY-GS12NA-U1 12,000 BTU · Ahu ×2
Ventilation
Broan NA 300 CFM · Kitchen Exhaust ×2
2 jobs · most recent 08/05/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/05/2026Signed-offM & M PIPING AND HEATINGGas, Water/Sanitary
09/30/2025Signed-offM & M PIPING AND HEATINGGas, Water/Sanitary
3 jobs · most recent 10/27/2025
General Wiring
FiledStatusContractorScope
10/27/2025Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
07/09/2024CancelledSKY ELECTRIC LLCGeneral Wiring
06/07/2024CancelledSKY ELECTRIC LLCGeneral Wiring
2 jobs · most recent 08/05/2026
Steel Concrete
FiledStatusContractorScope
08/05/2026Signed-offSPECTRA CONSTR & DEV CORPSteel, Concrete
09/30/2025Signed-offSPECTRA CONSTR & DEV CORPSteel
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
07/22/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/01/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/01/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/26/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/26/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/26/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/25/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
03/11/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/26/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/16/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 57
DateRequirementInspectorRole
08/05/2026Energy Code Compliance InspectionsRon Engprogress
08/05/2026Fire-Resistant Penetrations and JointsRon Engspecial
08/05/2026HVAC-R and service water piping design and insulationRon Engenergy_progress
08/04/2026Fire-Resistant Penetrations and JointsRon Engspecial
08/04/2026HVAC-R and service water piping design and insulationRon Engenergy_progress
08/04/2026Energy Code Compliance InspectionsRon Engprogress
09/29/2025Structural Steel - DetailsWilliam DeGraaffspecial
09/29/2025Structural Steel - DetailsWilliam DeGraaffspecial
09/29/2025Structural Steel - WeldingWilliam DeGraaffspecial
09/29/2025Structural Steel - High Strength BoltingWilliam DeGraaffspecial
09/29/2025Structural Stability – Alterations of existing buildingsWilliam DeGraaffspecial
09/29/2025Post-installed AnchorsWilliam DeGraaffspecial
09/29/2025Structural Steel - High Strength BoltingWilliam DeGraaffspecial
09/29/2025Post-installed AnchorsWilliam DeGraaffspecial
09/29/2025Concrete - Cast-In-PlaceWilliam DeGraaffspecial
09/29/2025Structural Steel - WeldingWilliam DeGraaffspecial
09/25/2025FinalWilliam DeGraaffprogress
09/25/2025FinalWilliam DeGraaffprogress
09/25/2025Structural Stability – Alterations of existing buildingsWilliam DeGraaffspecial
04/04/2025HVAC-R and service water heating equipmentRon Engenergy_progress
04/04/2025Mechanical SystemsRon Engspecial
04/04/2025Fire-Resistant Penetrations and JointsRon Engspecial
04/04/2025FinalRon Engprogress
04/04/2025Energy Code Compliance InspectionsRon Engprogress
04/04/2025Fire-Resistance Rated ConstructionRon Engprogress
Latest 25 of 57.
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/20/2026B01206045-P1Request digital key ↗
08/20/2026B01206045-S2Request digital key ↗
08/20/2026B01206045-S1Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature12
08/30/2026B01206045-P1Open ↗
08/30/2026B01206045-P1Open ↗
08/29/2026B01206045-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026B01206045-P1Open ↗
08/20/2026B01194010-I1Open ↗
08/20/2026B01194010-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/30/2026B01206045-P1Open ↗
08/29/2026B01206045-S1Open ↗
08/27/2026B01194010-I1Open ↗
Showing 3 of 6 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/20/2026B01206045-P1Open ↗
08/20/2026B01194010-S2Open ↗
08/20/2026B01194010-S1Open ↗
Showing 3 of 7 on file for this type