← Back
BROOKLYN
87 WINTHROP STREET
BROOKLYN · BIN 3430479
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
6 Open Violations ▸
Locations of Work
ArchitectureMechanicalFire Protection
Permit Issued — active, not yet Signed-off
PenthouseUnder Construction1 filing · 20 docs
Floor 4Under Construction1 filing · 20 docs
Floor 3Under Construction1 filing · 20 docs
Floor 2Under Construction1 filing · 20 docs
Floor 1Under Construction1 filing · 20 docs
CellarUnder Construction1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BLUE CHIP PAINTING CONTRACTING509/15/2026
▾Design Consultants (Architect / Engineer of Record)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MCKENNEY CONSTRUCTION LLCGeneral Contractor308/27/2026
METFLOW FIRE CONTROL LLCFire Protection106/27/2026
MES CONSTRUCTION CORPPlumbing107/14/2026
PLUMB-IT MECHANICAL INCPlumbing106/02/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616907/08/2026
Building Lifecycle
All (51)Filed (15)Permit Issued (20)Signed Off (4)Violation (12)
08/26/2026
Permit issued — Curb Cut
B00294857-I1-CC
08/24/2026
Signed off — Alteration
INSTALLATION OF HEAVY-DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE.
B01271862-I1
07/13/2026
Permit issued — Plumbing
B42856898-S3-PL
07/08/2026
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-P4
06/17/2026
Permit issued — Construction Fence
B01161645-S1-FN
06/17/2026
Permit issued — General Construction
B01161645-I1-GC
06/14/2026
Violation issued (ECB, open)
Construction
05/20/2026
Signed off — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S4
05/07/2026
Signed off — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S6
04/24/2026
Permit issued — Sprinklers
B01161645-S3-EW-SP
04/23/2026
Violation issued (ECB, closed)
Construction
04/23/2026
Violation issued (ECB, closed)
Unknown
04/23/2026
Violation issued (ECB, closed)
Unknown
03/02/2026
Violation issued (ECB, open)
Unknown
03/02/2026
Violation issued (ECB, open)
Unknown
03/02/2026
Violation issued (ECB, open)
Construction
02/26/2026
Violation issued (ECB, open)
Unknown
02/26/2026
Violation issued (ECB, closed)
Site Safety
02/26/2026
Violation issued (ECB, open)
Construction
01/12/2026
Permit issued — Supported Scaffold
B01161645-S9-SF
12/11/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S9
09/08/2025
Permit issued — Mechanical Systems
B01161645-S2-MS
08/27/2025
Permit issued — Plumbing
B01161645-S3-PL
08/20/2025
Filed — Alteration
INSTALLATION OF HEAVY-DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. SIDEWALK SHED SHALL COMPLY WITH CHAPTER 33 OF THE 2022 NYC BUILDING CODE.
B01271862-I1
08/20/2025
Permit issued — Sidewalk Shed
B01271862-I1-SH
07/21/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/04/2025
Permit issued — Construction Fence
B01161645-S1-FN
06/04/2025
Permit issued — Foundation
B01161645-S6-FO-EA
06/04/2025
Permit issued — Support of Excavation
B01161645-S4-SE
06/04/2025
Permit issued — General Construction
B01161645-I1-GC
06/04/2025
Permit issued — Structural
B01161645-S5-ST
05/28/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-P3
05/20/2025
Violation issued (ECB, closed)
Construction
05/13/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-P2
05/13/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-P1
05/06/2025
Permit issued — Earth Work
B01161645-S6-FO-EA
05/01/2025
Permit issued — Structural
B01161645-S5-ST
04/28/2025
Permit issued — Support of Excavation
B01161645-S4-SE
04/28/2025
Permit issued — General Construction
B01161645-I1-GC
04/09/2025
Signed off — Full Demolition
Demo of two family dwelling
B01152644-I1
04/01/2025
Permit issued — Full Demolition
B01152644-I1-FD
03/26/2025
Permit issued — Construction Fence
B01161645-S1-FN
03/25/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S6
03/24/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S4
03/24/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S5
03/05/2025
Filed — Full Demolition
Demo of two family dwelling
B01152644-I1
02/10/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S2
02/10/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S3
01/23/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-I1
01/23/2025
Filed — New Building
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION B01161645-I1
B01161645-S1
03/13/2020
Filed — Alteration
B00294857-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutPermit IssuedMCKENNEY CONSTRUCTION LLC08/26/2026
DOB NOWPlumbingSigned-offMES CONSTRUCTION CORP07/13/2026
DOB NOWConstruction FenceSigned-offMCKENNEY CONSTRUCTION LLC06/17/2026
DOB NOWGeneral ConstructionPermit IssuedMCKENNEY CONSTRUCTION LLC06/17/2026
DOB NOWSprinklersPermit IssuedMETFLOW FIRE CONTROL LLC04/24/2026
DOB NOWSupported ScaffoldSigned-offMCKENNEY CONSTRUCTION LLC01/12/2026
DOB NOWMechanical SystemsPermit IssuedMCKENNEY CONSTRUCTION LLC09/08/2025
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC08/27/2025
DOB NOWSidewalk ShedSigned-offJ.K.CONSTRUCTION NEW YORK08/20/2025
DOB NOWConstruction FenceSigned-offMCKENNEY CONSTRUCTION LLC06/04/2025
DOB NOWFoundationSigned-offMCKENNEY CONSTRUCTION LLC06/04/2025
DOB NOWSupport of ExcavationSigned-offMCKENNEY CONSTRUCTION LLC06/04/2025
DOB NOWGeneral ConstructionPermit IssuedMCKENNEY CONSTRUCTION LLC06/04/2025
DOB NOWStructuralSigned-offMCKENNEY CONSTRUCTION LLC06/04/2025
DOB NOWEarth WorkSigned-offMCKENNEY CONSTRUCTION LLC05/06/2025
DOB NOWStructuralSigned-offMCKENNEY CONSTRUCTION LLC05/01/2025
DOB NOWSupport of ExcavationSigned-offMCKENNEY CONSTRUCTION LLC04/28/2025
DOB NOWGeneral ConstructionPermit IssuedMCKENNEY CONSTRUCTION LLC04/28/2025
DOB NOWFull DemolitionSigned-offMCKENNEY CONSTRUCTION LLC04/01/2025
DOB NOWConstruction FenceSigned-offMCKENNEY CONSTRUCTION LLC03/26/2025
1 project · most recent 07/08/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/08/2026Signed-offMCKENNEY CONSTRUCTION LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-4C36NA4-U1 36,000 BTU · Heat Pump Outdoor ×4
MXZ-SM48NAM2-U1 50,000 BTU · Heat Pump Outdoor ×3
MXZ-SM36NAM2-U1 41,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 07/08/2026
Sprinkler System
FiledStatusContractorScope
07/08/2026Permit IssuedMETFLOW FIRE CONTROL LLCSprinkler System
1 project · most recent 07/08/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/08/2026Signed-offPLUMB-IT MECHANICAL INCStorm, Water/Sanitary
2 projects · most recent 09/29/2026
General Wiring
FiledStatusContractorScope
09/29/2026Permit IssuedAPPROVED ELECTRIC CORP.General Wiring
08/28/2025CompleteHIGH QUALITY ELEC.OF NYC—
1 project · most recent 07/08/2026
Concrete Masonry
FiledStatusContractorScope
07/08/2026Permit IssuedMCKENNEY CONSTRUCTION LLCConcrete, Masonry
2 projects · most recent 07/08/2026
Fence Sidewalk Shed
FiledStatusContractorScope
07/08/2026Signed-offMCKENNEY CONSTRUCTION LLCFence
08/20/2025Signed-offJ.K.CONSTRUCTION NEW YORKSidewalk Shed
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/21/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/21/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/21/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/10/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/05/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/05/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
06/30/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
06/30/2026Fenestration air leakageFAHAD FATEHenergy_progress
06/30/2026Protection of exposed foundation insulationFAHAD FATEHenergy_progress
06/30/2026Fenestration areasFAHAD FATEHenergy_progress
06/30/2026Exterior lighting powerFAHAD FATEHenergy_progress
06/30/2026MeteringFAHAD FATEHenergy_progress
06/30/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
06/30/2026Lighting in dwelling unitsFAHAD FATEHenergy_progress
06/30/2026Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
06/30/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/30/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
06/30/2026Insulation placement and R valuesFAHAD FATEHenergy_progress
06/30/2026Lighting controlsFAHAD FATEHenergy_progress
06/30/2026Interior lighting powerFAHAD FATEHenergy_progress
01/05/2026Alternative Materials - OTCR Buildings Bulletin NumberSHAHRIAR QUAYYUMspecial
01/05/2026Post-installed AnchorsSHAHRIAR QUAYYUMspecial
05/30/2025Subgrade InspectionsFAHAD FATEHspecial
05/30/2025Excavations - Sheeting, Shoring, and BracingFAHAD FATEHspecial
05/14/2025Post-installed AnchorsFAHAD FATEHspecial
05/14/2025FinalFAHAD FATEHprogress
05/14/2025Footing and FoundationFAHAD FATEHprogress
05/14/2025Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
05/14/2025FinalFAHAD FATEHprogress
05/14/2025Structural Cold-Formed SteelFAHAD FATEHspecial
05/14/2025MasonryFAHAD FATEHspecial
Latest 25 of 56.
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch14
08/22/2026B01152644-I1Request digital key ↗
08/21/2026B01161645-S9Request digital key ↗
08/21/2026B01161645-S3Request digital key ↗
Showing 3 of 14 on file for this type
▸DOB NOWPlans/Sketch - Curb Cut1
09/02/2026B00294857-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZoning Exhibit form (1-5)1
08/15/2026B01161645-P4Open ↗
▸Seals & Professional Certifications34
▸DOB NOWDPL-1: Design Professional Seal & Signature14
08/21/2026B01161645-P3Open ↗
08/21/2026B01161645-S3Open ↗
08/21/2026B01161645-S2Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
08/30/2026B01161645-P4Open ↗
08/28/2026B01161645-S3Open ↗
08/27/2026B01161645-S9Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
08/30/2026B01161645-P4Open ↗
08/30/2026B01161645-P4Open ↗
08/28/2026B01161645-S3Open ↗
Showing 3 of 10 on file for this type
▸Trade Schedules & Equipment4
▸DOB NOWElectric Cut-Off1
08/13/2026B01152644-I1Open ↗
▸DOB NOWWater Cut-Off1
08/13/2026B01152644-I1Open ↗
▸DOB NOWGas Cut-Off1
08/13/2026B01152644-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/13/2026B01152644-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01152644-I1Open ↗
▸DOB NOWRodent Control1
08/13/2026B01152644-I1Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification3
08/21/2026B01161645-I1Open ↗
08/15/2026B01161645-P4Open ↗
08/13/2026B01152644-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/13/2026B01152644-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/13/2026B01152644-I1Open ↗