← Back
Two stories - detached, small or mid-size
8795 20 AVENUE
BROOKLYN · Bath Beach · BIN 3168805
💬 Discuss this project
1925Year Built
2.75Stories
A1Building Class
R5Zoning
2,580 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 3,383 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Attic16p · 3 filings · 20 docs
Floor 220p · 4 filings · 20 docs
Floor 119p · 3 filings · 20 docs
Cellar24p · 4 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
J&R DESIGN AND INSPECTION CORP.512/20/2022
NY BUILDING ASSOCIATES INC102/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 3381203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor603/21/2026
AMERICAN STANDARD P&H CORORP.Plumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637512/20/2022
NKM ENGINEERING PLLC6244102/18/2022
Building Lifecycle
All (53)Filed (6)Permit Issued (5)Violation (2)Inspection (10)Special Inspection (30)
01/09/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/21/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
12/21/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
12/21/2022
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
12/21/2022
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
12/21/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
12/20/2022
Filed — Alteration
FILE PLUMBING WORK WITH INSTALLATION OF FIXTURES AS PER PLAN TO CONJUNCT WITH DOB NOW JOB B00654544, B00662657.
B00775185-P1
11/23/2022
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
11/23/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
11/23/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
11/23/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
11/23/2022
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
11/10/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/01/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/27/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/21/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/21/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/09/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/27/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/27/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
07/27/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
07/27/2022
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
07/27/2022
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
07/27/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
07/21/2022
Permit issued — Plumbing
B00775185-I1-PL
07/18/2022
Filed — Alteration
FILE PLUMBING WORK WITH INSTALLATION OF FIXTURES AS PER PLAN TO CONJUNCT WITH DOB NOW JOB B00654544, B00662657.
B00775185-I1
07/14/2022
Filed — Alteration
FILE PLUMBING WORK WITH INSTALLATION OF FIXTURES AS PER PLAN. CONSTRUCTION WORK FILED UNDER #B00631504. NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00654544-P1
07/14/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
07/14/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
07/14/2022
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
07/14/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
07/14/2022
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
03/14/2022
Permit issued — General Construction
B00662657-I1-GC
02/18/2022
Filed — Alteration CO
B00662657-I1
02/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
02/17/2022
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
02/17/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
02/17/2022
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
02/17/2022
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
02/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/19/2022
Permit issued — Plumbing
B00654544-I1-PL
01/17/2022
Permit issued — General Construction
B00661282-I1-GC
01/17/2022
Permit issued — General Construction
B00661282-I1-MS
01/12/2022
Filed — Alteration
FILE PLUMBING WORK WITH INSTALLATION OF FIXTURES AS PER PLAN. CONSTRUCTION WORK FILED UNDER #B00631504. NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00654544-I1
01/12/2022
Filed — Alteration
GENERAL RENOVATION OF 3-STORY BUILDING WITH REMOVING PARTITION, REPAIRING CEILING WALLS, REPLACING WINDOWS, NEW FLOOR TILES, PARTITION, DOORS, PAINTING, REPAIRING FRONT STAIRS AND NEW SPLIT AC AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00661282-I1
01/12/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
01/12/2022
Special inspection requirement — Mechanical Systems
Robert Truskosky
01/12/2022
Special inspection requirement — Concrete - Cast-In-Place
Robert Truskosky
01/12/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
01/12/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Robert Truskosky
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.07/21/2022
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION03/14/2022
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.01/19/2022
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION01/17/2022
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION01/17/2022
1 project · most recent 01/12/2022
Air Conditioning Systems
FiledStatusContractorScope
01/12/2022Permit IssuedHIGH QUALITY CONSTRUCTIONAir Conditioning Systems
2 projects · most recent 12/20/2022
Gas Water/Sanitary
FiledStatusContractorScope
12/20/2022Signed-offAMERICAN STANDARD P&H CORGas, Water/Sanitary
07/14/2022Signed-offAMERICAN STANDARD P&H CORGas, Water/Sanitary
1 project · most recent 03/23/2022
General Wiring
FiledStatusContractorScope
03/23/2022Permit IssuedGOODALL ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
01/09/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/10/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/01/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/27/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/09/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/09/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/27/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/27/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/27/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
12/21/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
12/21/2022HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
12/21/2022HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
12/21/2022HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
12/21/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
11/23/2022HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
11/23/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
11/23/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
11/23/2022HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
11/23/2022HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
07/27/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
07/27/2022HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
07/27/2022HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
07/27/2022HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
07/27/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
07/14/2022Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
07/14/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
07/14/2022HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
07/14/2022HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
07/14/2022HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
02/17/2022Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
02/17/2022Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
02/17/2022Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
02/17/2022Fenestration air leakageNARESH MAHANGUenergy_progress
02/17/2022Energy Code Compliance InspectionsNARESH MAHANGUprogress
Latest 25 of 41.
▾Documents — 76 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/31/2026B00654544-I1Request digital key ↗
08/31/2026B00654544-P1Request digital key ↗
08/31/2026B00661282-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications60
▸DOB NOWProgress Inspector Seal & Signature40
09/01/2026B00661282-P1Open ↗
09/01/2026B00661282-P1Open ↗
09/01/2026B00661282-P1Open ↗
Showing 3 of 40 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/01/2026B00661282-P1Open ↗
09/01/2026B00661282-P1Open ↗
09/01/2026B00661282-P1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/29/2026B00775185-I1Open ↗
08/29/2026B00775185-P1Open ↗
08/13/2026B00661282-P1Open ↗
Showing 3 of 7 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B00662657-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/29/2026B00775185-I1Open ↗
08/29/2026B00775185-P1Open ↗
08/13/2026B00662657-I1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026B00662657-I1Open ↗