← Back
Elevator cooperative
88-08 151 AVENUE
QUEENS · Howard Beach-Lindenwood · BIN 4434846
💬 Discuss this project
1962Year Built
6Stories
D4Building Class
R5Zoning
149,000 sfGross Floor Area
151Units
LL97 CoveredRent Stabilized23 Open Violations 21 unresolved · 2 paperwork only ▸FISP: UNSAFEFDNY Report ↗
Elevator cooperative · Owner of record: LINDENWOOD VILLAGE SEC B CO OP CORP · 94,880 sf lot · 1.57 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
RoofUnder Construction5p · 2 filings · 10 docs
Floor 6Under Construction5p · 2 filings · 10 docs
Floor 5Under Construction5p · 2 filings · 10 docs
Floor 4Under Construction5p · 2 filings · 10 docs
Floor 3Under Construction5p · 2 filings · 10 docs
Floor 2Under Construction5p · 2 filings · 10 docs
Floor 1Under Construction5p · 2 filings · 10 docs
CellarUnder Construction4p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AL GHAZALI CONSTRUCTION309/26/2026
LINDENWOOD VILLAGE SECTION B COOP C1807/08/2026
JASCO907/08/2026
DINAM DEVELOPMENT804/09/2026
LINDENWOOD VILLAGE SEC B CO-OP1303/22/2026
AVARGA CONTRACTING103/21/2026
LINDEWOOD103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EUGENE ARCHITECTURE302/06/2025
MJE PROFESSIONAL SERVICES105/16/2023
ENTHINK ENGINEERS LLC104/15/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BOYD CONSULTING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DINAM DEVELOPMENT CORPGeneral Contractor1607/08/2026
JASCO, INCGeneral Contractor707/08/2026
CLAIRMONT LONDONElectrical103/21/2026
INTERNATIONAL EMPIRE ELECElectrical103/22/2026
LONDON CLAIRMONTElectrical103/21/2026
M&A PROJECTS RESTORATION*General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARK ENGINEERING PC7261202/06/2025
EUGENE ARCHITECTURE P.C.8045108/16/2022
Building Lifecycle
All (115)Filed (6)Permit Issued (16)Signed Off (2)Facade (FISP) (22)Violation (60)Special Inspection (9)
09/25/2026
Permit issued — Suspended Scaffold
Q01465516-I1-SC
08/26/2026
Permit issued — Suspended Scaffold
Q01443111-I1-SC
08/09/2026
Filed — Alteration
Q01443111-I1
04/29/2026
Signed off — Alteration
Q00871644-I1
01/16/2026
Permit issued — Sidewalk Shed
Q00717636-I1-SH
10/22/2025
Permit issued — Structural
Q08038400-I1-GC-CX
08/04/2025
Permit issued — Supported Scaffold
Q00871644-I1-SF
07/22/2025
Signed off — Alteration
Filing for general construction work consisting of firestopping for penetrations and installation of new fire-rated CMU wall in boiler room to address ECB violation #35308585N. No change in use, egress, or occupancy.
Q01166753-I1
04/29/2025
Permit issued — General Construction
Q01166753-I1-GC
03/18/2025
Permit issued — Sidewalk Shed
Q00717636-I1-SH
02/06/2025
Filed — Alteration
Filing for general construction work consisting of firestopping for penetrations and installation of new fire-rated CMU wall in boiler room to address ECB violation #35308585N. No change in use, egress, or occupancy.
Q01166753-I1
01/29/2025
Cycle 9 facade report submitted
01/29/2025
Cycle 9 facade report signed — UNSAFE
01/14/2025
Special inspection requirement — Tenant Protection Plan Compliance
George Lau
01/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
George Lau
01/14/2025
Special inspection requirement — Final
Eugene Sellers
01/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
Eugene Sellers
12/09/2024
Cycle 9 facade inspection completed
10/23/2024
Permit issued — Structural
Q08038400-I1-GC-CX
06/18/2024
Permit issued — Supported Scaffold
Q00871644-I1-SF
04/15/2024
Violation issued (HPD, closed)
A
03/18/2024
Permit issued — Sidewalk Shed
Q00717636-I1-SH
02/13/2024
Cycle 9 facade report submitted
02/13/2024
Cycle 9 facade report signed — UNSAFE
01/12/2024
Cycle 9 facade inspection completed
10/24/2023
Permit issued — General Construction
Q00780134-I1-GC
10/20/2023
Permit issued — General Construction
Q08038400-I1-GC-CX
10/04/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/16/2023
Filed — Alteration
Q00871644-I1
05/16/2023
Permit issued — Supported Scaffold
Q00871644-I1-SF
03/29/2023
Violation issued (ECB, closed)
Elevators
03/28/2023
Permit issued — Sidewalk Shed
Q00717636-I1-SH
03/28/2023
Violation issued (HPD, closed)
A
12/01/2022
Filed — Alteration
Q08038400-I1
11/16/2022
Violation issued (HPD, closed)
I
11/10/2022
Special inspection requirement — Construction Operations Influencing Adjacent Structures
George Lau
11/10/2022
Special inspection requirement — Final
Eugene Sellers
11/10/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
George Lau
11/10/2022
Special inspection requirement — Tenant Protection Plan Compliance
George Lau
11/10/2022
Special inspection requirement — Structural Steel - Welding
George Lau
10/14/2022
Permit issued — General Construction
Q00780134-I1-GC
08/16/2022
Filed — Alteration
NETTING TO BE INSTALLED AT DETERIORATED AREAS OF CONCRETE BALCONYSLAB EDGES. NETTING TO BE DESIGNED TO PREVENT DISPLACEMENT OFAFFECTED MATERIALS UNTIL SUCH TIME AS MORE PERMANENT REPAIRS CANBE MADE. no change to use, egress or occupancy.
Q00780134-I1
07/18/2022
Cycle 9 facade report submitted
07/18/2022
Cycle 9 facade report signed — UNSAFE
07/15/2022
Cycle 9 facade inspection completed
05/20/2022
Violation issued (ECB, open)
Construction
05/18/2022
Cycle 9 facade report submitted
05/07/2022
Cycle 9 facade inspection completed
04/15/2022
Filed — Alteration
Q00717636-I1
04/15/2022
Permit issued — Sidewalk Shed
Q00717636-I1-SH
03/30/2022
Violation issued (ECB, open)
Construction
03/30/2022
Violation issued (ECB, closed)
Construction
03/16/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/04/2022
Violation issued (HPD, closed)
A
02/18/2022
Cycle 9 facade report submitted
02/18/2022
Cycle 9 facade report signed — UNSAFE
02/18/2022
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/18/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/11/2022
Cycle 9 facade inspection completed
12/17/2021
Violation issued (ECB, closed)
Elevators
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldPermit IssuedAL-GHAZALI CONSTRUCTION09/25/2026
DOB NOWSuspended ScaffoldPermit IssuedAL-GHAZALI CONSTRUCTION08/26/2026
DOB NOWSidewalk ShedPermit IssuedJASCO, INC01/16/2026
DOB NOWStructuralPermit IssuedDINAM DEVELOPMENT CORP10/22/2025
DOB NOWSupported ScaffoldSigned-offDINAM DEVELOPMENT CORP08/04/2025
DOB NOWGeneral ConstructionSigned-offM&A PROJECTS RESTORATION*04/29/2025
DOB NOWSidewalk ShedPermit IssuedJASCO, INC03/18/2025
DOB NOWStructuralPermit IssuedDINAM DEVELOPMENT CORP10/23/2024
DOB NOWSupported ScaffoldSigned-offDINAM DEVELOPMENT CORP06/18/2024
DOB NOWSidewalk ShedPermit IssuedJASCO, INC03/18/2024
DOB NOWGeneral ConstructionPermit IssuedDINAM DEVELOPMENT CORP10/24/2023
DOB NOWGeneral ConstructionPermit IssuedDINAM DEVELOPMENT CORP10/20/2023
DOB NOWSupported ScaffoldSigned-offDINAM DEVELOPMENT CORP05/16/2023
DOB NOWSidewalk ShedPermit IssuedJASCO, INC03/28/2023
DOB NOWGeneral ConstructionPermit IssuedDINAM DEVELOPMENT CORP10/14/2022
DOB NOWSidewalk ShedPermit IssuedJASCO, INC04/15/2022
BISOTISSUEDA & J CHIMNEY CLEANING &08/29/2018
BISFSISSUEDACE ATLAS CORP01/20/2016
BISFSISSUEDACE ATLAS CORP09/14/2015
BISOTISSUEDAVARGA CONTRACTING CORP06/30/2015
BISEQISSUEDAVARGA CONTRACTING CORP06/30/2015
BISEQISSUEDSPRING SCAFFOLDING LLC06/10/2015
BISFBISSUEDEFFICIENT COMB&COOLING CO11/21/2014
BISOTISSUEDXINOS CONSTRUCTION CORP07/18/2012
BISEQISSUEDXINOS CONSTRUCTION CORP06/11/2012
BISEQISSUEDXINOS CONSTRUCTION CORP09/01/2011
BISOTISSUEDXINOS CONSTRUCTION CORP09/01/2011
BISOTISSUEDBOCCIA INC08/09/2005
BIS—ISSUEDVARSITY PLUMBING & HEATING01/19/2005
BISOTISSUEDBOCCIA INC06/07/2004
BISEQISSUEDCOLGATE SCAFFOLDING05/13/2004
BISEQISSUEDTOWER BLDG. RESTORATION CORP.09/28/2000
BISOTISSUEDTOWER BUILDING RESTORATION09/01/2000
BISEQISSUEDTOWER BLDG. RESTORATION CORP.08/15/2000
BISOTISSUEDTOWER BUILDING RESTORATION11/06/1998
BISEQISSUEDT B R INC10/28/1998
4 projects · most recent 06/11/2024
General Wiring
FiledStatusContractorScope
06/11/2024CompleteINTERNATIONAL EMPIRE ELECGeneral Wiring
04/19/2022Permit IssuedRICHARD NEU—
05/27/2020Permit IssuedVERE ELECTRIC CORP.General Wiring
01/11/2018CompleteMULTI-TECH ELECTRIC, INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
01/14/2025Tenant Protection Plan ComplianceGeorge Lauspecial
01/14/2025Fire-Resistant Penetrations and JointsGeorge Lauspecial
01/14/2025FinalEugene Sellersprogress
01/14/2025Fire-Resistance Rated ConstructionEugene Sellersprogress
11/10/2022Construction Operations Influencing Adjacent StructuresGeorge Lauspecial
11/10/2022FinalEugene Sellersprogress
11/10/2022Structural Stability – Alterations of existing buildingsGeorge Lauspecial
11/10/2022Tenant Protection Plan ComplianceGeorge Lauspecial
11/10/2022Structural Steel - WeldingGeorge Lauspecial
▾Documents — 144 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026Q00717636-I1Request digital key ↗
08/26/2026Q00780134-I1Request digital key ↗
08/25/2026Q08038400-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits20
▸BISWORK PERMIT APPLICATION11
08/27/2018440504991Open ↗
01/21/2016440251077Open ↗
09/14/2015440251077Open ↗
Showing 3 of 11 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION8
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
Showing 3 of 8 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
02/05/2016440225560Open ↗
▸Seals & Professional Certifications41
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
11/14/2018440504991Open ↗
12/13/2017420477068Open ↗
05/31/2016440251077Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/26/2026Q00717636-I1Open ↗
08/25/2026Q08038400-P1Open ↗
08/25/2026Q08038400-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION4
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
12/04/2014420917510Open ↗
06/16/2012420579822Open ↗
09/06/2011420477068Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY4
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q01166753-I1Open ↗
08/23/2026Q01166753-I1Open ↗
08/22/2026Q08038400-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
06/16/2012420579822Open ↗
08/19/2011420472189Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q01166753-I1Open ↗
08/22/2026Q08038400-I1Open ↗
▸BISProfessional and Owner Certification (POC3)1
09/06/2011420477068Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
09/14/2015440251077Open ↗
12/04/2014420917510Open ↗
▸Safety & Tenant Protection3
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
07/26/2012420579822Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
07/23/2012420579822Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
08/27/2018440504991Open ↗
▸Environmental & Asbestos9
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
08/19/2011420472189Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01166753-I1Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/25/2026Q08038400-I1Open ↗
▸Energy Compliance18
▸BISAS-BUILT ENERGY ANALYSIS6
11/14/2018440504991Open ↗
05/31/2016440251077Open ↗
12/29/2015440229744Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
11/14/2018440504991Open ↗
05/31/2016440251077Open ↗
02/12/2013420579822Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
▸BISTECHNICAL REPORT: ENERGY1
08/19/2011420472189Open ↗
▸BISTR8: Energy Code Progress Inspections1
02/22/2012420472189Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
06/09/2015440225560Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
▸Approvals, Objections & Sign-offs18
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
12/11/2018440504991Open ↗
12/13/2017420477068Open ↗
05/31/2016440251077Open ↗
Showing 3 of 7 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION6
11/13/2018440504991Open ↗
11/13/2018440504991Open ↗
05/31/2016440251077Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
12/09/2014420917510Open ↗
06/16/2012420579822Open ↗
09/06/2011420477068Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP Variance (V5) letter1
08/13/2026Q08038400-I1Open ↗
▸Cost, Insurance & Ownership11
▸BISCOST AFFIDAVIT11
11/14/2018440504991Open ↗
08/27/2018440504991Open ↗
05/31/2016440251077Open ↗
Showing 3 of 11 on file for this type
▸Filing & Intake Forms9
▸BISEFILING JOB APPLICATION COVER SHEET4
08/27/2018440504991Open ↗
09/14/2015440251077Open ↗
06/29/2015440229744Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET4
12/04/2014420917510Open ↗
06/16/2012420579822Open ↗
09/06/2011420477068Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM1
12/13/2017420477068Open ↗
▸Other Documents3
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026Q08038400-I1Open ↗
▸DOB NOWCalculations1
08/16/2026Q01443111-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/16/2026Q01443111-I1Open ↗