← Back
Predominantly retail with other uses
88-15 HOLLIS COURT BLVD
QUEENS · Queens Village · BIN 4225960
💬 Discuss this project
2023Year Built
2Stories
K4Building Class
R2Zoning
6,497 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: 88-15 HOLLIS COURT LLC. · 5,556 sf lot · 1.17 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentCivilGeneral
Roof17p · 3 filings · 20 docs
Floor 215p · 3 filings · 19 docs
Floor 115p · 4 filings · 20 docs
Mezzanine1p · 1 filing · 5 docs
Cellar16p · 4 filings · 20 docs
Site & exterior12p · 5 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
8815 HOLLIS COURT1604/09/2026
CONSTRUCTION SVS CON NY707/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/07/2019$712K—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AYA303/21/2026
S R SOLAR DESIGN403/21/2026
Allan Yang Architect, P.C.203/21/2026
IDA DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WNS CONSTRUCTION CORPGeneral Contractor707/08/2026
CONSTRUCTION SVS CON NYGeneral Contractor607/08/2026
NAMRON, INCGeneral Contractor507/08/2026
PARAMOUNT PIPING INCGeneral Contractor407/08/2026
STRUCTURE R US INCGeneral Contractor303/21/2026
PARAMOUNT PIPING INCPlumbing207/08/2026
W.R. PLBG AND HTG CORPPlumbing107/08/2026
HYTECH SOLAR INCGeneral Contractor104/09/2026
NEKA ELECTRIC INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244203/11/2026
S&S CONCRETE & SOIL TESTI1008305/25/2023
Building Lifecycle
All (75)Filed (11)Permit Issued (17)Signed Off (8)Violation (2)Inspection (5)Objection (2)Special Inspection (30)
06/22/2026
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK.
Q01071289-I1
03/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/17/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
03/17/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/17/2026
Special inspection requirement — Final
NARESH MAHANGU
03/11/2026
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK.
Q01071289-P1
03/09/2026
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/09/2026
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
03/09/2026
Special inspection requirement — Final
NARESH MAHANGU
03/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
10/20/2025
Signed off — Alteration
HEREWITH FILING MECHANICAL APPLICATION IN CONJUNCTION WITH NB APPLICATION #421962488.
Q00427415-I1
10/20/2025
Signed off — Alteration
HEREWITH FILING PLUMBING APPLICATION IN CONJUCTION WITH NB APPLICATION #421962488.
Q00427380-I1
08/04/2025
Signed off — Alteration
Q00605422-I1
03/20/2025
Permit issued — Mechanical Systems
Q00427415-I1-MS
01/21/2025
Signed off — Alteration
PROPOSED INSTALLATION OF PIPE SCAFFOLD FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Q00555171-I1
01/21/2025
Signed off — Alteration
Q00555219-I1
12/30/2024
Permit issued — Solar
Q01071289-I1-SL
12/10/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/03/2024
Special inspection requirement — HVAC and service water heating equipment
GLEN LANGER
12/03/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
12/03/2024
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
GLEN LANGER
12/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
12/03/2024
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
12/03/2024
Special inspection requirement — HVAC and service water heating system controls
GLEN LANGER
12/03/2024
Special inspection requirement — Maintenance information
GLEN LANGER
12/03/2024
Special inspection requirement — HVAC insulation and sealing
GLEN LANGER
12/02/2024
Filed — Alteration
HEREWITH FILING PLUMBING APPLICATION IN CONJUCTION WITH NB APPLICATION #421962488.
Q00427380-P1
11/21/2024
Objection resolved — Addressed
10/25/2024
Signed off — Alteration
INSTALLATION OF TWO 10" GALVANIZED STEEL PIPING SLEEVES THROUGH CONCRETE FOUNDATION WALL INCLUDING TWO 6" DIAMETER SHCI PIPING APPROXIMATELY 5'L IN CELLAR. IN CONJUNCTION WITH NB APPLICATION 421962488 AND DOB NOW PL APPLICATION Q00427380-I1.
Q01102169-I1
09/06/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
09/05/2024
Objection raised — Other
08/29/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK.
Q01071289-I1
08/28/2024
Permit issued — Plumbing
Q01102169-I1-PL
08/27/2024
Filed — Alteration
INSTALLATION OF TWO 10" GALVANIZED STEEL PIPING SLEEVES THROUGH CONCRETE FOUNDATION WALL INCLUDING TWO 6" DIAMETER SHCI PIPING APPROXIMATELY 5'L IN CELLAR. IN CONJUNCTION WITH NB APPLICATION 421962488 AND DOB NOW PL APPLICATION Q00427380-I1.
Q01102169-I1
08/26/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/03/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/08/2024
Permit issued — Mechanical Systems
Q00427415-I1-MS
12/15/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/01/2023
Permit issued — Mechanical Systems
Q00427415-I1-MS
11/29/2023
Permit issued — Earth Work
Q00598678-I1-GC-CX
11/13/2023
Permit issued — Plumbing
Q00427380-I1-PL
11/13/2023
Permit issued — Construction Fence
Q00605422-I1-FN
05/25/2023
Filed — Alteration
HEREWITH FILING MECHANICAL APPLICATION IN CONJUNCTION WITH NB APPLICATION #421962488.
Q00427415-I1
05/17/2023
Permit issued — Sidewalk Shed
Q00555219-I1-SH
01/03/2023
Violation issued (ECB, closed)
Construction
12/13/2022
Permit issued — Sidewalk Shed
Q00555219-I1-SH
06/02/2022
Permit issued — Plumbing
Q00427380-I1-PL
02/14/2022
Permit issued — Construction Fence
Q00605422-I1-FN
12/21/2021
Permit issued — Construction Fence
Q00605422-I1-FN
11/17/2021
Filed — Alteration
HEREWITH FILING PLUMBING APPLICATION IN CONJUCTION WITH NB APPLICATION #421962488.
Q00427380-I1
10/27/2021
Signed off — Alteration
THIS JOB IS FILED FOR CONSTRUCTION FENCE FOR DEMOLITION WORK AT 88-15 HOLLIS COURT BLVD, QUEENS, JOB#421783369.
Q00505593-I1
10/22/2021
Permit issued — Construction Fence
Q00605422-I1-FN
10/14/2021
Filed — Alteration
Q00605422-I1
09/27/2021
Filed — Alteration
Herewith filing for structural, foundation / earth work and SOE work types in conjunction with NB application# 421962488.
Q00598678-I1
09/22/2021
Special inspection requirement — Footing and Foundation
GLEN LANGER
09/22/2021
Special inspection requirement — Concrete - Cast-In-Place
GLEN LANGER
09/22/2021
Special inspection requirement — Structural Steel - High Strength Bolting
GLEN LANGER
09/22/2021
Special inspection requirement — Structural Steel - Welding
GLEN LANGER
09/22/2021
Special inspection requirement — Subgrade Inspections
GLEN LANGER
09/22/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
GLEN LANGER
Latest 60 of 75 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offNAMRON, INC03/20/2025
DOB NOWSolarSigned-offHYTECH SOLAR12/30/2024
DOB NOWPlumbingSigned-offW.R. PLBG AND HTG CORP08/28/2024
DOB NOWMechanical SystemsSigned-offNAMRON, INC03/08/2024
DOB NOWMechanical SystemsSigned-offNAMRON, INC12/01/2023
DOB NOWEarth WorkPermit IssuedPARAMOUNT PIPING INC11/29/2023
DOB NOWPlumbingSigned-offSURPASS PLBG & HTG INC11/13/2023
DOB NOWConstruction FenceSigned-offPARAMOUNT PIPING INC11/13/2023
DOB NOWSidewalk ShedSigned-offCONSTRUCTION SVS CON NY05/17/2023
DOB NOWSidewalk ShedSigned-offCONSTRUCTION SVS CON NY12/13/2022
DOB NOWPlumbingSigned-offSURPASS PLBG & HTG INC06/02/2022
DOB NOWConstruction FenceSigned-offWNS CONSTRUCTION CORP02/14/2022
DOB NOWConstruction FenceSigned-offWNS CONSTRUCTION CORP12/21/2021
DOB NOWConstruction FenceSigned-offWNS CONSTRUCTION CORP10/22/2021
DOB NOWSidewalk ShedSigned-offCONSTRUCTION SVS CON NY07/12/2021
DOB NOWSupported ScaffoldSigned-offCONSTRUCTION SVS CON NY07/12/2021
DOB NOWConstruction FenceSigned-offSTRUCTURE R US INC06/24/2021
BIS—ISSUEDPARAMOUNT PIPING INC06/17/2025
BIS—ISSUEDSTRUCTURE R US INC07/13/2021
3 projects · most recent 07/15/2024
General Wiring
FiledStatusContractorScope
07/15/2024CompleteGMJ ELECTRIC CORP—
04/11/2024CompletePW & SONS ELECTRICAL CORPGeneral Wiring
08/03/2021CompleteNEKA ELECTRIC INC1 meters, 1 new_meters
1 project · most recent 09/27/2021
Masonry
FiledStatusContractorScope
09/27/2021Permit IssuedPARAMOUNT PIPING INCMasonry
1 project · most recent 03/11/2026
FiledStatusContractorScope
03/11/2026Signed-offHYTECH SOLAR INC96 panels, 46.08 kw, 118.76 roof_area_sqft
1 project · most recent 09/27/2021
Earthwork
FiledStatusContractorScope
09/27/2021Permit IssuedPARAMOUNT PIPING INCEarthwork
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
12/10/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
09/06/2024Pass-Final PL - UndergroundPassView ↗
08/26/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/03/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/15/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
03/17/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/17/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
03/17/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/17/2026FinalNARESH MAHANGUprogress
03/09/2026Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/09/2026Air barrier - visual inspectionNARESH MAHANGUenergy_progress
03/09/2026FinalNARESH MAHANGUprogress
03/09/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
12/03/2024HVAC and service water heating equipment GLEN LANGERenergy_progress
12/03/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
12/03/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesGLEN LANGERspecial
12/03/2024Fire-Resistant Penetrations and JointsGLEN LANGERspecial
12/03/2024Energy Code Compliance InspectionsGLEN LANGERprogress
12/03/2024HVAC and service water heating system controls GLEN LANGERenergy_progress
12/03/2024Maintenance informationGLEN LANGERenergy_progress
12/03/2024HVAC insulation and sealing GLEN LANGERenergy_progress
09/22/2021Footing and FoundationGLEN LANGERprogress
09/22/2021Concrete - Cast-In-PlaceGLEN LANGERspecial
09/22/2021Structural Steel - High Strength BoltingGLEN LANGERspecial
09/22/2021Structural Steel - WeldingGLEN LANGERspecial
09/22/2021Subgrade InspectionsGLEN LANGERspecial
09/22/2021Excavations - Sheeting, Shoring, and BracingGLEN LANGERspecial
09/22/2021Structural Stability – Alterations of existing buildingsGLEN LANGERspecial
09/22/2021Structural Steel - DetailsGLEN LANGERspecial
09/22/2021UnderpinningGLEN LANGERspecial
Latest 25 of 36.
▾Documents — 108 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch8
08/27/2026Q00505593-I1Request digital key ↗
08/27/2026Q00555219-I1Request digital key ↗
08/27/2026Q00555171-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸DOB NOWPlans/Sketch - Plumbing2
08/21/2026Q00427380-P1Request digital key ↗
08/21/2026Q00427380-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/24/2026Q00427415-I1Request digital key ↗
▸Applications & Permits12
▸BISPLAN / WORK APPROVAL APPLICATION8
09/04/2025440625272Open ↗
08/22/2023421962488Open ↗
05/26/2023421962488Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION2
06/28/2024421962488Open ↗
09/15/2021421783369Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
06/20/2024421962488Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
09/08/2025440625272Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISZONING DIAGRAM1
02/03/2021421962488Open ↗
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/24/2026Q00427415-I1Open ↗
08/21/2026Q01071289-I1Open ↗
08/21/2026Q00427380-P1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/01/2026Q00427380-I1Open ↗
09/01/2026Q00427380-I1Open ↗
08/31/2026Q00598678-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/01/2026Q00427380-I1Open ↗
08/31/2026Q00598678-I1Open ↗
08/27/2026Q01071289-P1Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/07/2020440625272Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/07/2020440625272Open ↗
▸Trade Schedules & Equipment4
▸BISGAS CUT-OFF1
09/15/2021421783369Open ↗
▸BISELECTRIC CUT-OFF1
09/15/2021421783369Open ↗
▸BISSEWER CUT-OFF1
09/15/2021421783369Open ↗
▸BISHEATING SYSTEMS1
10/21/2025421962488Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST2
11/04/2020440625272Open ↗
06/02/2020421962488Open ↗
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
09/15/2021421783369Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
09/15/2021421783369Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
09/15/2021421783369Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/15/2021421783369Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
01/15/2021421962488Open ↗
10/07/2020440625272Open ↗
▸BISTR8: ENERGY CODE PROGRESS INSPS TECHNICAL REPORT1
11/04/2020440625272Open ↗
▸BISNYCECC ANALYSIS1
11/04/2020440625272Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
10/21/2025421962488Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
10/21/2025421962488Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/07/2020440625272Open ↗
▸BISENERGY CODE COMPE REVIEW AND APPROVAL1
01/15/2021421962488Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00427380-I1Open ↗
▸Inspections & Test Reports10
▸BISTECHNICAL REPORT: RESPONSIBILITY3
06/22/2022421962488Open ↗
01/15/2021421962488Open ↗
06/02/2020421962488Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF2
10/21/2025421962488Open ↗
04/28/2023421962488Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
01/15/2021421962488Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
10/21/2025421962488Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
10/21/2025421962488Open ↗
▸BISSOIL REPORT1
01/15/2021421962488Open ↗
▸BISMECHANICAL SYSTEMS1
10/21/2025421962488Open ↗
▸Approvals, Objections & Sign-offs8
▸BISSCHEDULE A - OCCUPANCY / USE3
01/27/2021421962488Open ↗
01/25/2021421962488Open ↗
01/14/2021421962488Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
09/15/2021421783369Open ↗
09/15/2021421783369Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
09/15/2021421783369Open ↗
▸BISLANDMARKS APPROVAL1
09/15/2021421783369Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01071289-I1Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT1
06/02/2020421962488Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
06/24/2024421962488Open ↗
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE1
09/15/2021421783369Open ↗
▸Filing & Intake Forms12
▸BISADDITIONAL INFORMATION4
10/14/2025440625272Open ↗
09/08/2025440625272Open ↗
02/03/2021421962488Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM3
09/15/2021421783369Open ↗
11/12/2020421783369Open ↗
04/29/2020421962488Open ↗
▸BISEFILING COVER SHEET3
11/12/2020421783369Open ↗
06/02/2020421962488Open ↗
04/29/2020421962488Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
11/04/2020440625272Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/07/2020440625272Open ↗
▸Other Documents5
▸BISSUSTAINABLE ROOF ZONE FORM1
06/02/2020421962488Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
06/20/2024421962488Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
11/04/2020440625272Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
10/07/2020440625272Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00598678-I1Open ↗