← Back
Three families
88-19 82 AVENUE
QUEENS · BIN 4094651
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R4-1Zoning
2,520 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · 2,700 sf lot · 0.93 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 2 filings · 20 docs
Floor 11 filing
Cellar1 filing
1 job · most recent 02/12/2021
Gas Water/Sanitary
FiledStatusContractorScope
02/12/2021Signed-offWATSON'S PLBG, HTG, & BDGGas, Water/Sanitary
Building Lifecycle
All (24)Filed (3)Permit Issued (2)Violation (5)Special Inspection (14)
05/06/2026
Violation issued (HPD, closed)
A
03/28/2023
Violation issued (HPD, closed)
A
03/03/2022
Violation issued (HPD, closed)
A
04/15/2021
Violation issued (HPD, closed)
A
02/16/2021
Special inspection requirement — Maintenance information
Yuan Liu
02/16/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yuan Liu
02/16/2021
Special inspection requirement — Energy Code Compliance Inspections
Yuan Liu
02/16/2021
Special inspection requirement — Fire-Resistance Rated Construction
Yuan Liu
02/16/2021
Special inspection requirement — HVAC insulation and sealing
Yuan Liu
02/16/2021
Special inspection requirement — HVAC and service water heating equipment
Yuan Liu
02/16/2021
Special inspection requirement — HVAC and service water heating system controls
Yuan Liu
02/12/2021
Filed — Alteration
RENOVATION OF EXISTING 3-FAMILY HOUSE WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATER ON CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00412225-P2
02/12/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yuan Liu
02/12/2021
Special inspection requirement — Energy Code Compliance Inspections
Yuan Liu
02/12/2021
Special inspection requirement — Fire-Resistance Rated Construction
Yuan Liu
02/12/2021
Special inspection requirement — HVAC and service water heating equipment
Yuan Liu
02/12/2021
Special inspection requirement — Maintenance information
Yuan Liu
02/12/2021
Special inspection requirement — HVAC and service water heating system controls
Yuan Liu
02/12/2021
Special inspection requirement — HVAC insulation and sealing
Yuan Liu
01/18/2021
Filed — Alteration
RENOVATION OF EXISTING 3-FAMILY HOUSE WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATER ON CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00412225-P1
10/16/2020
Permit issued — Plumbing
Q16475675-I1-PL
10/14/2020
Filed — Alteration
RENOVATION OF EXISTING 3-FAMILY HOUSE WITH PLUMBING WORK: RELOCATE KITCHEN AND BATHROOM FIXTURES; NEW BOILERS AND HOT WATER HEATER ON CELLAR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Q00412225-I1
10/14/2020
Permit issued — Plumbing
Q00412225-I1-PL
11/01/2019
Violation issued (HPD, closed)
I
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
201 AUTUMN AVE607/08/2026
8819 82 AVENUE103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/13/2020$985K—— → —$391/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YL DESIGN GROUP302/12/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WATSON'S PLBG, HTG, & BDGPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YL DESIGN GROUP LLC7584302/12/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG10/16/2020
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG10/14/2020
BISOTISSUEDYILIN CONSTRUCTION INC10/14/2020
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
02/16/2021Maintenance informationYuan Liuenergy_progress
02/16/2021Fire-Resistant Penetrations and JointsYuan Liuspecial
02/16/2021Energy Code Compliance InspectionsYuan Liuprogress
02/16/2021Fire-Resistance Rated ConstructionYuan Liuprogress
02/16/2021HVAC insulation and sealing Yuan Liuenergy_progress
02/16/2021HVAC and service water heating equipment Yuan Liuenergy_progress
02/16/2021HVAC and service water heating system controls Yuan Liuenergy_progress
02/12/2021Fire-Resistant Penetrations and JointsYuan Liuspecial
02/12/2021Energy Code Compliance InspectionsYuan Liuprogress
02/12/2021Fire-Resistance Rated ConstructionYuan Liuprogress
02/12/2021HVAC and service water heating equipment Yuan Liuenergy_progress
02/12/2021Maintenance informationYuan Liuenergy_progress
02/12/2021HVAC and service water heating system controls Yuan Liuenergy_progress
02/12/2021HVAC insulation and sealing Yuan Liuenergy_progress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing3
08/27/2026Q00412225-I1Request digital key ↗
08/15/2026Q00412225-P1Request digital key ↗
08/15/2026Q00412225-P2Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
02/02/2021440634299Open ↗
01/06/2021440634299Open ↗
10/07/2020440634299Open ↗
▸BISWORK PERMIT APPLICATION1
10/14/2020440634299Open ↗
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature12
08/31/2026Q00412225-P2Open ↗
08/31/2026Q00412225-P2Open ↗
08/31/2026Q00412225-P2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00412225-P2Open ↗
08/27/2026Q00412225-P1Open ↗
08/27/2026Q00412225-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026Q00412225-P2Open ↗
08/23/2026Q00412225-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/07/2020440634299Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/07/2020440634299Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/07/2020440634299Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026Q00412225-P1Open ↗
08/27/2026Q00412225-P2Open ↗
08/27/2026Q00412225-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/07/2020440634299Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/07/2020440634299Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/14/2020440634299Open ↗
▸BISNYCECC ANALYSIS1
10/07/2020440634299Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
10/14/2020440634299Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
10/07/2020440634299Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
10/07/2020440634299Open ↗
▸BISADDITIONAL INFORMATION1
02/02/2021440634299Open ↗