← Back
Three families
88 BALTIC STREET
BROOKLYN · BIN 3343458
💬 Discuss this project
1995Year Built
3Stories
C0Building Class
R6BZoning
3,024 sfGross Floor Area
3Units
Three families · 1,975 sf lot · 1.53 FAR built · Flood zone X500
Locations of Work
Architecture
Floor 11p · 1 filing · 20 docs
1 job · most recent 08/13/2019
General Wiring
FiledStatusContractorScope
08/13/2019CompleteCITY GRID ELECTRIC CORPGeneral Wiring
Building Lifecycle
All (34)Filed (5)Permit Issued (3)Signed Off (3)Special Inspection (23)
11/26/2025
Signed off — Alteration
B00200373-I1
11/10/2020
Signed off — Alteration
ADD NEW TANKLESS GAS HOT WATER HEATER AT CELLAR. REMOVE TUB, GAS HWH AND GAS BOILER AT 1ST FLOOR. RELOCATE WC, LAV, SINK, DW, AND STOVE AT 1ST FLOOR.
B00200371-I1
11/10/2020
Signed off — Alteration
B00317852-I1
09/22/2020
Permit issued — Construction Fence
B00317852-I1-FN
09/18/2020
Special inspection requirement — HVAC and service water heating system controls
John Hatheway
09/18/2020
Special inspection requirement — HVAC and service water heating equipment
John Hatheway
09/18/2020
Special inspection requirement — Maintenance information
John Hatheway
09/18/2020
Special inspection requirement — Fire-Resistance Rated Construction
John Hatheway
09/18/2020
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
09/18/2020
Special inspection requirement — HVAC insulation and sealing
John Hatheway
09/14/2020
Filed — Alteration
ADD NEW TANKLESS GAS HOT WATER HEATER AT CELLAR. REMOVE TUB, GAS HWH AND GAS BOILER AT 1ST FLOOR. RELOCATE WC, LAV, SINK, DW, AND STOVE AT 1ST FLOOR.
B00200371-P2
03/03/2020
Permit issued — Mechanical Systems
B00200373-I1-MS
03/02/2020
Filed — Alteration
B00200373-I1
02/27/2020
Filed — Alteration
B00317852-I1
02/20/2020
Filed — Alteration
ADD NEW TANKLESS GAS HOT WATER HEATER AT CELLAR. REMOVE TUB, GAS HWH AND GAS BOILER AT 1ST FLOOR. RELOCATE WC, LAV, SINK, DW, AND STOVE AT 1ST FLOOR.
B00200371-P1
02/11/2020
Special inspection requirement — Maintenance information
John Hatheway
02/11/2020
Special inspection requirement — HVAC and service water heating equipment
John Hatheway
02/11/2020
Special inspection requirement — HVAC and service water heating system controls
John Hatheway
01/22/2020
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
01/22/2020
Special inspection requirement — Fire-Resistance Rated Construction
John Hatheway
01/22/2020
Special inspection requirement — HVAC insulation and sealing
John Hatheway
01/03/2020
Permit issued — Plumbing
B00200371-I1-PL
12/04/2019
Filed — Alteration
ADD NEW TANKLESS GAS HOT WATER HEATER AT CELLAR. REMOVE TUB, GAS HWH AND GAS BOILER AT 1ST FLOOR. RELOCATE WC, LAV, SINK, DW, AND STOVE AT 1ST FLOOR.
B00200371-I1
09/23/2019
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
07/26/2019
Special inspection requirement — Final
John Hatheway
07/26/2019
Special inspection requirement — Duct leakage testing
John Hatheway
07/26/2019
Special inspection requirement — Electrical motors
John Hatheway
07/26/2019
Special inspection requirement — HVAC insulation and sealing
John Hatheway
07/26/2019
Special inspection requirement — Permanent certificate
John Hatheway
07/26/2019
Special inspection requirement — HVAC and service water heating system controls
John Hatheway
07/26/2019
Special inspection requirement — HVAC and service water heating equipment
John Hatheway
07/26/2019
Special inspection requirement — Shutoff dampers
John Hatheway
07/26/2019
Special inspection requirement — Mechanical Systems
John Hatheway
07/26/2019
Special inspection requirement — Maintenance information
John Hatheway
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
N Y C DEPT OF PREV DEVELOP103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOHN H HATHEWAY JR., ARCHITECT509/14/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAMI CONSTRUCTION & REMODGeneral Contractor603/21/2026
PACIFIC PLBG&HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOHN H HATHEWAY JR., ARCH4175103/02/2020
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offSAMI CONSTRUCTION & REMOD09/22/2020
DOB NOWMechanical SystemsSigned-offSAMI CONSTRUCTION & REMOD03/03/2020
DOB NOWPlumbingSigned-offPACIFIC PLBG&HTG CORP01/03/2020
BISOTISSUEDSAMI CONSTRUCTION & REMOD01/07/2020
BISOTISSUEDSAMI CONSTRUCTION & REMOD11/06/2019
BIS—ISSUEDCOLUMBIA STREET HOSING CO LP07/01/1996
BISPLISSUEDDUO PLUMBING & HTG CORP.08/22/1995
BIS—RE-ISSUEDCOLUMBIA STREET HOSING CO LP04/03/1995
▾Special Inspection Requirements (DOB NOW) — 23
DateRequirementInspectorRole
09/18/2020HVAC and service water heating system controls John Hathewayenergy_progress
09/18/2020HVAC and service water heating equipment John Hathewayenergy_progress
09/18/2020Maintenance informationJohn Hathewayenergy_progress
09/18/2020Fire-Resistance Rated ConstructionJohn Hathewayprogress
09/18/2020Energy Code Compliance InspectionsJohn Hathewayprogress
09/18/2020HVAC insulation and sealing John Hathewayenergy_progress
02/11/2020Maintenance informationJohn Hathewayenergy_progress
02/11/2020HVAC and service water heating equipment John Hathewayenergy_progress
02/11/2020HVAC and service water heating system controls John Hathewayenergy_progress
01/22/2020Energy Code Compliance InspectionsJohn Hathewayprogress
01/22/2020Fire-Resistance Rated ConstructionJohn Hathewayprogress
01/22/2020HVAC insulation and sealing John Hathewayenergy_progress
09/23/2019Energy Code Compliance InspectionsJohn Hathewayprogress
07/26/2019FinalJohn Hathewayprogress
07/26/2019Duct leakage testing John Hathewayenergy_progress
07/26/2019Electrical motorsJohn Hathewayenergy_progress
07/26/2019HVAC insulation and sealing John Hathewayenergy_progress
07/26/2019Permanent certificateJohn Hathewayenergy_progress
07/26/2019HVAC and service water heating system controls John Hathewayenergy_progress
07/26/2019HVAC and service water heating equipment John Hathewayenergy_progress
07/26/2019Shutoff dampersJohn Hathewayenergy_progress
07/26/2019Mechanical SystemsJohn Hathewayspecial
07/26/2019Maintenance informationJohn Hathewayenergy_progress
▾Documents — 65 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch - Plumbing3
09/02/2026B00200371-I1Request digital key ↗
08/15/2026B00200371-P1Request digital key ↗
08/15/2026B00200371-P2Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/02/2026B00200373-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00317852-I1Request digital key ↗
▸Applications & Permits5
▸BISWORK PERMIT APPLICATION2
01/08/2020321973049Open ↗
11/07/2019321973049Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
10/30/2019321973049Open ↗
07/18/2019321973049Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
03/12/2020321973049Open ↗
▸Seals & Professional Certifications26
▸DOB NOWProgress Inspector Seal & Signature19
09/02/2026B00200373-I1Open ↗
09/02/2026B00200373-I1Open ↗
09/02/2026B00200373-I1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/13/2026B00317852-I1Open ↗
08/13/2026B00200371-P1Open ↗
08/13/2026B00200371-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/18/2019321973049Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/02/2026B00200373-I1Open ↗
▸Safety & Tenant Protection8
▸DOB NOWTenant Protection Plan5
08/13/2026B00200371-P2Open ↗
08/13/2026B00317852-I1Open ↗
08/13/2026B00200371-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTenant Protection Plan and Notes2
10/30/2019321973049Open ↗
07/18/2019321973049Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
11/07/2019321973049Open ↗
▸Environmental & Asbestos7
▸DOB NOWOER: Notice to Proceed4
08/13/2026B00200371-P2Open ↗
08/13/2026B00317852-I1Open ↗
08/13/2026B00200371-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWOER: Notice of Satisfaction2
08/13/2026B00317852-I1Open ↗
08/13/2026B00200371-I1Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
11/19/2020321973049Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/19/2020321973049Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/19/2020321973049Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/18/2019321973049Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/19/2020321973049Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/19/2020321973049Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/19/2020321973049Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT (FINAL): PW31
11/19/2020321973049Open ↗
▸BISCOST AFFIDAVIT1
07/18/2019321973049Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
09/25/2025321973049Open ↗
03/21/2020321973049Open ↗
▸BISEFILING COVER SHEET1
07/18/2019321973049Open ↗
▸Other Documents3
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION3
11/07/2019321973049Open ↗
11/07/2019321973049Open ↗
11/07/2019321973049Open ↗