ECB04/27/2026Failure to maintain parking structure in safe conditions. As noted:-attime of inspection of an occupied parking structures consisting of 02 levels. Observed cellar level occupied as a parking garage and observe$2K due
ECB01/22/2026Failure to obey a vacate order from the commissioner. Noted; at time of inspection garage has been observed still being occupied with several vehicles while vacate order still being in place. Partial vacate ord$10K due
DOB01/14/2026Ewo. Occupied parking structing 1 cellar lvl. Spalled,cracked concrete encasement, slab, column exposed,fallen,corroded steel rebars.deterior flooring causing an immediate hazard to vehicular & pedestrian traffic requring immediate safety measures. Remedy:owner to retain a nys reg design prof to direct/supv installation of safety measures
ECB01/14/2026Failure to maintain parking structure in safe condition. Note: at timeof inspection on an occupied parking structure consisting of 1 cellar level, observed spalled-cracked concrete(slab, beams, columns), severl$2K due
DOB09/27/2024Failurue to maintain bldg in a safe condition.feu observe that the concrete encasemnt were crckd exposng the steel.loose rebars&remaining spalld concrete present overhead hazards.immediately comply with commissioner's order 343780 (070924FEU01ZT) to repair building under permit
DOB07/09/2024Failure to maintain bldg in a safe condition.feu observed that the concrete encasmnt were crckd exposng the steel.loose rebars&remaining spalld concrete present overhead hazards.vacate entire prkng garage ownr to immed rtain nyspe to eval the ent bldg,dtrmne the strctrl stbility,&prepare/file dwgs
ECB10/01/2024Failure to submit the required parking structure initial observation report for an existing parking structure documenting the conditions of psid#X0006076 by the august 1,2024 deadline.to date,the department hasNothing owed — awaiting certificate of correction