| Owner | Filings | Most Recent |
|---|---|---|
| Arirang | 14 | 03/21/2026 |
| Hamilton Harbor Associates | 13 | 03/21/2026 |
| 8812-8814 Fourth Ave | 10 | 03/22/2026 |
| Tranchina | 7 | 07/08/2026 |
| West 104 St Associates | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Scaglione Architects | 3 | 09/29/2025 |
| Reynaldo C. Prego, PE | 2 | 05/01/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| Planhandlers | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Maximum Contracting | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| A Tech Engineering NYC, P | 6738 | 2 | 05/01/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | Maximum Contracting | 07/03/2024 |
| BIS | MH | ISSUED | Dibenedetto Heating & Air Condit | 09/11/2018 |
| BIS | PL | ISSUED | R.S.F. Plumbing & Heating | 09/11/2018 |
| BIS | MH | ISSUED | Empire State Mechanical * | 05/24/2017 |
| BIS | OT | ISSUED | Atlantic Hoisting & Scaff | 02/22/2011 |
| BIS | OT | ISSUED | Atlantic Hoisting & Scaff | 02/22/2011 |
| BIS | OT | ISSUED | Atlantic Hoisting & Scaffol | 03/08/2010 |
| BIS | OT | ISSUED | Atlantic Hoisting & Scaffol | 03/08/2010 |
| BIS | OT | ISSUED | Atlantic Hoisting & Scaffol | 02/05/2010 |
| BIS | OT | ISSUED | Atlantic Hoisting & Scaffol | 11/24/2009 |
| BIS | FP | ISSUED | Allied Fire Control Service | 02/11/2008 |
| BIS | PL | ISSUED | Mr. Plumber | 03/07/2006 |
| BIS | PL | ISSUED | K.M.D. Mechanical 1443 | 05/20/2003 |
| BIS | MH | ISSUED | Peter Steven Quanci & Associates | 10/31/2002 |
| BIS | PL | ISSUED | K.M.D. Mechanical 1443 | 02/01/2002 |
| BIS | PL | ISSUED | K.M.D. Mechanical 1443 | 02/01/2002 |
| BIS | SP | ISSUED | K.M.D. Mechanical 1443 | 01/28/2002 |
| BIS | MH | ISSUED | 5 Boro Mechanical | 04/07/2000 |
| BIS | PL | ISSUED | Steven Thomas Heating | 04/09/1999 |
| BIS | OT | ISSUED | Intrepid Electrical Contrating | 03/24/1999 |
| BIS | PL | ISSUED | Steven Thomas Heating | 03/24/1999 |
| BIS | PL | ISSUED | Steven Thomas Heating | 03/19/1999 |
| BIS | — | ISSUED | Intrepid Electric Contracting Co | 02/10/1999 |
| BIS | FP | ISSUED | Reliable Fire Protection | 01/21/1999 |
| BIS | PL | ISSUED | Pilato Brothers Plumbing & Heating Co | 02/21/1995 |
| BIS | PL | ISSUED | Pilato Brothers Plumbing & Heating Co | 01/23/1995 |
| BIS | PL | ISSUED | Pilato Brothers Plumbing & Heating Co | 01/23/1995 |
| BIS | FP | ISSUED | Reliable Fire Protection | 04/12/1993 |
| BIS | SP | ISSUED | Pilato Brothers & P&H Co | 03/16/1993 |
| BIS | SP | ISSUED | Pilato Brothers PLG | 03/16/1993 |
| BIS | PL | ISSUED | Pilato Brothers Plumbing & Heating Co | 02/17/1993 |
| BIS | PL | ISSUED | Pilato Brothers Plumbing & Heating Co | 02/11/1993 |
| BIS | MH | ISSUED | Intrepid Electrical Contracting | 02/04/1993 |
| BIS | OT | ISSUED | Intrepid Electrical Contracting | 02/02/1993 |
| BIS | EQ | ISSUED | Intrepid Electrical Contracting | 01/29/1993 |
| BIS | — | ISSUED | Intrepid Electrical Contracting | 01/27/1993 |
| BIS | — | ISSUED | Intrepid Electrical Contracting | 01/27/1993 |
| BIS | MH | ISSUED | Intrepid Electrical Contracting | 10/26/1992 |
| BIS | EQ | ISSUED | Intrepid Electrical Contracting | 10/26/1992 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/01/2025 | Permit Issued | Maximum Contracting | Air Conditioning Systems | Cooling Comfort Aire Five (5) Comfort-Aire Condensing Units, Model #s HMG60F1P 60,000 BTU · Condensing Unit ×5 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/28/2025 | — | — | Gas, Water/Sanitary |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/27/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 07/27/2025 | Structural Stability – Alterations of existing buildings | — | special |
| 07/27/2025 | Energy Code Compliance Inspections | — | progress |
| 07/27/2025 | Fire-Resistance Rated Construction | — | progress |
| 07/27/2025 | Lighting in dwelling units | — | energy_progress |
| 07/27/2025 | Permanent certificate | — | energy_progress |
| 07/27/2025 | Metering | — | energy_progress |
| 12/23/2024 | Structural Stability – Alterations of existing buildings | — | special |
| 11/10/2023 | HVAC-R and service water heating equipment | anthony santoro | energy_progress |
| 11/10/2023 | HVAC-R and service water heating system controls | anthony santoro | energy_progress |
| 11/10/2023 | Maintenance information | anthony santoro | energy_progress |
| 11/10/2023 | HVAC-R and service water piping design and insulation | anthony santoro | energy_progress |
| 11/10/2023 | Fire-Resistant Penetrations and Joints | anthony santoro | special |
| 08/29/2023 | Mechanical Systems | anthony santoro | special |
| 08/29/2023 | Final | anthony santoro | progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Arirang Restaurant | Restaurant / Food Service | Roof | Project B00926596 |