DOB08/16/1993V-DOB VIOLATION - ACTIVE
ECB06/17/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED FIRE ESCAPE DROP LADDER. OBSTRUCTED BY FIXED BENCH. LOCATED AT EXPOSURE 1. PREVIOUS VIO#3A18763, REPAIR AND/REPLACENothing owed — awaiting certificate of correction
ECB06/17/2026HYDROTHERM BOILER MISSING RATINGS LABEL, MOTORIZED COMBUSTION AIR LOUVER MISSING WHISKER SWITCH. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB06/30/2025& BC 1024.2 (2022 CODE) FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. FIRE ESCAPE OBSTRUCTED WITH FIXED PARK BENCH EXPOSURE 2 AND TREE LEAVES AND BRANCHES OBSTRUCTING AT EXPOSURE 3. POTENTIAL HAZARD., REMOVENothing owed — awaiting certificate of correction
ECB06/30/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS. THROUGHOUT BASEMENT LEVEL. POTENTIAL FIRE HAZARD., PRNothing owed — awaiting certificate of correction
ECB06/11/2024HYDROTHERM MODEL-MR1200 BOILER. MISSING BOILER RATING TAG, MISSING WISKER SWITCH ON FRESH AIR LOUVER. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB09/20/2022AT CELLAR/BASEMENT LEVEL JIM CAP INSTALLED AND ALSO NOT HOLDING ON 4 INCH CAST IRON FITTING. THIS IS A HAZARDOUS CONDITION BECAUSE IT ALLOWS WASTE WATER AND ALSO BACTERIA TO SEEP INTO OPEN AREAS., REPAIR AND/ORNothing owed — awaiting certificate of correction
ECB08/31/2022I OBSERVED IN THE BASEMENT ELECTRICAL EQUIPMENT ROOM THE GROUND CONDUITS IN A STATE OF CORROSION. ALL SECTIONS OF THE GROUND MUST BE COMPLETE MECHANICAL CONDITION. ALSO NOTED NO WATER METER JUMPER INSTALLED. RENothing owed — awaiting certificate of correction
ECB08/31/2022I OBSERVED IN THE PREVIOUS LAUNDRY ROOM IN THE BASEMENT THE UNPERMITTED USE OF A FLEXIBLE CORD AS PERMANENT WIRING SUPPLYING POWER TO AN IN-WALL INSTALLED VENTILATION FAN; 400.8. REMEDY: COMPLY WITH EC CODE;Nothing owed — awaiting certificate of correction
ECB10/15/2021#1 CIRCULATOR CORRODED AND GAUGE IS DEFECTIVE/MOTORIZED LOUVER NOT INTERLOCKED WITH ALL UNITS AND WHISKER SWITCH INSTALLED/BOILER RATING TAG MISSING;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction
ECB10/15/2021SAFETY DISCHARGE PIPE INCORRECT/FRONT JACKET NOT IN PLACE/OPENING IN BOILER ROOM DOOR/DEBRIS IN BOILER ROOM;CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction