← Back
Two family converted from one family
89-07 250 STREET
QUEENS · BIN 4177142
💬 Discuss this project
1930Year Built
2.5Stories
B3Building Class
R2AZoning
1,746 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.44 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Roof3p · 1 filing · 20 docs
Cellar3p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC610/16/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NASIR J. KHANZADA LLC1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JIT CONSTR COMPANY CORPGeneral Contractor507/08/2026
JOHN FITZGERALD PLBG &HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NASIR J. KHANZADA LLC1527510/16/2024
Building Lifecycle
All (72)Filed (6)Permit Issued (4)Signed Off (3)Violation (1)Inspection (4)Objection (24)Special Inspection (30)
08/28/2025
Signed off — Alteration
PAA FILED FOR MINOR CHANGES TO APPROVED PLANS TO MEET AS-BUILT CONDITIONS
Q00896966-I1
07/30/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/25/2025
Signed off — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT-2 FILING FOR INTERIOR RENOVATION OF EXISTING FIREDAMAGED TWO FAMILY DWELLING
Q00911509-I1
07/25/2025
Signed off — Alteration
SITE FENCE FILING IN CONJUNCTIONWITH ALT-2 FILING FOR RENOVATION OFEXISTING FIRE DAMAGE TWO FAMILYDWELLING HOUSE #.....
Q00918584-I1
10/30/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Nasir Khanzada
10/30/2024
Special inspection requirement — Air barrier - visual inspection
Nasir Khanzada
10/30/2024
Special inspection requirement — Fenestration air leakage
Nasir Khanzada
10/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
Nasir Khanzada
10/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Nasir Khanzada
10/30/2024
Special inspection requirement — Insulation placement and R values
Nasir Khanzada
10/30/2024
Special inspection requirement — Fenestration areas
Nasir Khanzada
10/30/2024
Special inspection requirement — Metering
Nasir Khanzada
10/30/2024
Special inspection requirement — Interior lighting power
Nasir Khanzada
10/30/2024
Special inspection requirement — Lighting controls
Nasir Khanzada
10/30/2024
Special inspection requirement — Maintenance information
Nasir Khanzada
10/30/2024
Special inspection requirement — Protection of exposed foundation insulation
Nasir Khanzada
10/30/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Nasir Khanzada
10/30/2024
Special inspection requirement — HVAC-R and service water heating system controls
Nasir Khanzada
10/30/2024
Special inspection requirement — Final
Nasir Khanzada
10/30/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
10/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
10/30/2024
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
Nasir Khanzada
10/30/2024
Special inspection requirement — Concrete - Cast-In-Place
Nasir Khanzada
10/30/2024
Special inspection requirement — Masonry
Nasir Khanzada
10/23/2024
Objection raised — Structural
10/23/2024
Objection resolved — Addressed
10/23/2024
Objection raised — Zoning
10/23/2024
Objection resolved — Addressed
10/23/2024
Objection raised — Other
10/23/2024
Objection resolved — Addressed
10/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
10/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
10/17/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
10/16/2024
Filed — Alteration
PAA FILED FOR MINOR CHANGES TO APPROVED PLANS TO MEET AS-BUILT CONDITIONS
Q00896966-P2
10/16/2024
Special inspection requirement — Concrete - Cast-In-Place
Nasir Khanzada
10/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
10/16/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
10/16/2024
Special inspection requirement — Masonry
Nasir Khanzada
10/16/2024
Special inspection requirement — HVAC-R and service water heating equipment
Nasir Khanzada
10/16/2024
Special inspection requirement — Fenestration air leakage
Nasir Khanzada
10/16/2024
Special inspection requirement — Maintenance information
Nasir Khanzada
10/16/2024
Special inspection requirement — Fenestration areas
Nasir Khanzada
10/08/2024
Filed — Alteration
PLUMBING FILING IN CONJUNCTION WITH ALT-2 FILING FOR INTERIOR RENOVATION OF EXISTING FIREDAMAGED TWO FAMILY DWELLING
Q00911509-P2
04/11/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/11/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/28/2024
Permit issued — Plumbing
Q00911509-I1-PL
10/19/2023
Permit issued — Construction Fence
Q00918584-I1-FN
10/12/2023
Permit issued — Structural
Q00896966-I1-ST
10/12/2023
Permit issued — General Construction
Q00896966-I1-GC
09/27/2023
Filed — Alteration
PAA FILED FOR MINOR CHANGES TO APPROVED PLANS TO MEET AS-BUILT CONDITIONS
Q00896966-P1
09/27/2023
Objection resolved — Addressed
09/18/2023
Objection raised — Other
09/14/2023
Filed — Alteration
SITE FENCE FILING IN CONJUNCTIONWITH ALT-2 FILING FOR RENOVATION OFEXISTING FIRE DAMAGE TWO FAMILYDWELLING HOUSE #.....
Q00918584-I1
09/08/2023
Objection resolved — Addressed
09/07/2023
Objection resolved — Addressed
09/07/2023
Objection resolved — Addressed
09/05/2023
Objection resolved — Addressed
08/25/2023
Objection raised — Inspections
08/25/2023
Objection resolved — Addressed
08/25/2023
Objection raised — Zoning
Latest 60 of 72 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJOHN FITZGERALD PLBG &HTG03/28/2024
DOB NOWConstruction FenceSigned-offJIT CONSTR COMPANY CORP10/19/2023
DOB NOWStructuralSigned-offJIT CONSTR COMPANY CORP10/12/2023
DOB NOWGeneral ConstructionSigned-offJIT CONSTR COMPANY CORP10/12/2023
BISPLISSUEDL&J PLG & HTG CO OF NY IN02/25/2019
BISOTISSUEDMIR ISLAM02/19/2019
1 project · most recent 03/06/2024
General Wiring
FiledStatusContractorScope
03/06/2024CompleteSNB ELECTRICAL CONTNG CORGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/30/2025Pass-Final General Construction Non-Directive 14PassView ↗
10/17/2024Fail-Final General Construction Non-Directive 14FailView ↗
04/11/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/11/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
10/30/2024Structural Steel - High Strength BoltingNasir Khanzadaspecial
10/30/2024Air barrier - visual inspectionNasir Khanzadaenergy_progress
10/30/2024Fenestration air leakageNasir Khanzadaenergy_progress
10/30/2024HVAC-R and service water heating equipmentNasir Khanzadaenergy_progress
10/30/2024Fenestration and door U-factor and product ratingsNasir Khanzadaenergy_progress
10/30/2024Insulation placement and R valuesNasir Khanzadaenergy_progress
10/30/2024Fenestration areasNasir Khanzadaenergy_progress
10/30/2024MeteringNasir Khanzadaenergy_progress
10/30/2024Interior lighting powerNasir Khanzadaenergy_progress
10/30/2024Lighting controlsNasir Khanzadaenergy_progress
10/30/2024Maintenance informationNasir Khanzadaenergy_progress
10/30/2024Protection of exposed foundation insulationNasir Khanzadaenergy_progress
10/30/2024HVAC-R and service water piping design and insulationNasir Khanzadaenergy_progress
10/30/2024HVAC-R and service water heating system controlsNasir Khanzadaenergy_progress
10/30/2024FinalNasir Khanzadaprogress
10/30/2024Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
10/30/2024Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
10/30/2024Construction Utilizing CLT or SCL, Type IVNasir Khanzadaspecial
10/30/2024Concrete - Cast-In-PlaceNasir Khanzadaspecial
10/30/2024MasonryNasir Khanzadaspecial
10/18/2024Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
10/18/2024Energy Code Compliance InspectionsNasir Khanzadaprogress
10/16/2024Concrete - Cast-In-PlaceNasir Khanzadaspecial
10/16/2024Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
10/16/2024Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
Latest 25 of 44.
▾Documents — 78 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/24/2026Q00896966-I1Request digital key ↗
08/24/2026Q00896966-P2Request digital key ↗
08/24/2026Q00896966-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
11/01/2023421608371Open ↗
07/17/2019421608371Open ↗
10/05/2018421608371Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
02/27/2019421608371Open ↗
02/20/2019421608371Open ↗
▸Seals & Professional Certifications51
▸DOB NOWProgress Inspector Seal & Signature30
09/01/2026Q00896966-P2Open ↗
09/01/2026Q00896966-P2Open ↗
09/01/2026Q00896966-P2Open ↗
Showing 3 of 30 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/01/2026Q00896966-P2Open ↗
09/01/2026Q00896966-P2Open ↗
09/01/2026Q00896966-P2Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/24/2026Q00896966-P1Open ↗
08/24/2026Q00896966-I1Open ↗
08/24/2026Q00911509-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
10/26/2018421608371Open ↗
04/16/2018421608371Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
07/17/2019421608371Open ↗
10/05/2018421608371Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
04/16/2018421608371Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
11/10/2018421608371Open ↗
11/10/2018421608371Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/13/2026Q00896966-I1Open ↗
08/13/2026Q00911509-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
10/26/2018421608371Open ↗
04/16/2018421608371Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
11/10/2018421608371Open ↗
08/07/2018421608371Open ↗
04/16/2018421608371Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
04/16/2019421608371Open ↗
10/05/2018421608371Open ↗
▸BISEFILING COVER SHEET1