← Back
Three families
89-14 133 STREET
QUEENS · BIN 4196850
💬 Discuss this project
1925Year Built
2.5Stories
C0Building Class
R4Zoning
2,963 sfGross Floor Area
3Units
1 Open Violation ▸FDNY Report ↗
Three families · 4,400 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC204/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACA ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAY KAVI CORPORATION8500204/11/2025
Building Lifecycle
All (15)Filed (2)Permit Issued (1)Signed Off (1)Violation (1)Special Inspection (10)
05/15/2025
Signed off — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q00981401-I1
04/15/2025
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
04/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jay Kavi
04/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jay Kavi
04/15/2025
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
04/15/2025
Special inspection requirement — Final
Ayracon Almaraz
04/11/2025
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q00981401-P1
04/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jay Kavi
04/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jay Kavi
04/11/2025
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
04/11/2025
Special inspection requirement — Final
Ayracon Almaraz
04/11/2025
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
01/02/2024
Permit issued — Solar
Q00981401-I1-SL
12/26/2023
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q00981401-I1
10/01/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTRINITY SOLAR LLC01/02/2024
1 project · most recent 10/31/2024
FiledStatusContractorScope
10/31/2024CompleteREDLINE ELECTRIC INC3 meters
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
04/15/2025Air barrier - visual inspectionAyracon Almarazenergy_progress
04/15/2025Structural Stability – Alterations of existing buildingsJay Kavispecial
04/15/2025Fire-Resistant Penetrations and JointsJay Kavispecial
04/15/2025Energy Code Compliance InspectionsAyracon Almarazprogress
04/15/2025FinalAyracon Almarazprogress
04/11/2025Fire-Resistant Penetrations and JointsJay Kavispecial
04/11/2025Structural Stability – Alterations of existing buildingsJay Kavispecial
04/11/2025Energy Code Compliance InspectionsAyracon Almarazprogress
04/11/2025FinalAyracon Almarazprogress
04/11/2025Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q00981401-P1Request digital key ↗
08/20/2026Q00981401-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026Q00981401-I1Open ↗
09/01/2026Q00981401-I1Open ↗
09/01/2026Q00981401-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026Q00981401-I1Open ↗
09/01/2026Q00981401-I1Open ↗
08/24/2026Q00981401-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q00981401-I1Open ↗
08/20/2026Q00981401-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q00981401-I1Open ↗
08/20/2026Q00981401-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q00981401-I1Open ↗