← Back
Two stories - detached, small or mid-size
89-40 DESARC ROAD
QUEENS · BIN 4245643
💬 Discuss this project
1940Year Built
2Stories
A1Building Class
R4-1Zoning
1,200 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 1,625 sf lot · 0.74 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/13/2020$470K—Private party → Private party$392/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC101/20/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SLNY MANAGEMENT CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854101/20/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
08/21/2025
Signed off — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01166540-I1
01/27/2025
Permit issued — Solar
Q01166540-I1-SL
01/20/2025
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01166540-I1
01/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
01/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
01/13/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
01/13/2025
Special inspection requirement — Final
TOM PETERSEN
01/13/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSLNY MANAGEMENT CORP01/27/2025
1 project · most recent 01/10/2025
FiledStatusContractorScope
01/10/2025CompleteL.D.M. ELECTL CONTRS INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/13/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
01/13/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
01/13/2025Energy Code Compliance InspectionsTOM PETERSENprogress
01/13/2025FinalTOM PETERSENprogress
01/13/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01166540-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q01166540-I1Open ↗
09/01/2026Q01166540-I1Open ↗
09/01/2026Q01166540-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01166540-I1Open ↗
09/01/2026Q01166540-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026Q01166540-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026Q01166540-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01166540-I1Open ↗