← Back
Two stories - detached, small or mid-size
89-58 213 STREET
QUEENS · Queens Village · BIN 4503335
💬 Discuss this project
1925Year Built
2Stories
A1Building Class
R2Zoning
1,248 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
Two stories - detached, small or mid-size · 2,646 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 4 docs
Floor 13p · 1 filing · 4 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC108/01/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM EXPEDITING DRAFTING DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AM EXPEDITING DRAFTING &General Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244108/01/2023
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Inspection (2)Objection (8)Special Inspection (1)
01/06/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/02/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/20/2024
Permit issued — General Construction
Q00901747-I1-GC
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection resolved — Addressed
11/09/2023
Objection resolved — Addressed
11/09/2023
Objection resolved — Addressed
08/10/2023
Objection raised — Scope
08/10/2023
Objection raised — Scope
08/10/2023
Objection raised — Scope
08/10/2023
Objection raised — Scope
08/01/2023
Filed — Alteration
HEREWITH FILING PLANS TO SHOW INTERIOR RENOVATION DETACHED GARAGE ACCESSORY TO ONE FAMILY DWELLING, TO RESOLVE RCA# 4895213 & VIOLATION#39086629K. NO CHANGE IN USE EGRESS OR OCCUPANCY.
Q00901747-I1
08/01/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedAM EXPEDITING DRAFTING &09/20/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
01/06/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/02/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
08/01/2023Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
▾Documents — 4 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/24/2026Q00901747-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/24/2026Q00901747-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00901747-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/24/2026Q00901747-I1Open ↗