← Back
Two family converted from one family
89 SARATOGA AVENUE
BROOKLYN · Ocean Hill · BIN 3040392
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6Zoning
2,238 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family converted from one family · 1,420 sf lot · 1.58 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC101/16/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BERGER QUALITY ELEC'L CONElectrical103/22/2026
KAMTECH RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802101/16/2025
Building Lifecycle
All (15)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Objection (6)Special Inspection (5)
04/30/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
B01168011-I1
02/09/2025
Permit issued — Solar
B01168011-I1-SL
01/27/2025
Objection raised — Other
01/27/2025
Objection resolved — Addressed
01/27/2025
Objection raised — Other
01/27/2025
Objection resolved — Addressed
01/27/2025
Objection raised — Q-3
01/27/2025
Objection resolved — Addressed
01/16/2025
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
B01168011-I1
01/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
01/16/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
01/16/2025
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
01/16/2025
Special inspection requirement — Final
Kaijin Liang
01/16/2025
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
02/23/2011
Violation issued (HPD, open)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP02/09/2025
1 project · most recent 01/02/2025
FiledStatusContractorScope
01/02/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/16/2025Fire-Resistant Penetrations and JointsKaijin Liangspecial
01/16/2025Structural Stability – Alterations of existing buildingsKaijin Liangspecial
01/16/2025Energy Code Compliance InspectionsKaijin Liangprogress
01/16/2025FinalKaijin Liangprogress
01/16/2025Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B01168011-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
10/03/2026B01168011-I1Open ↗
10/03/2026B01168011-I1Open ↗
10/03/2026B01168011-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
10/03/2026B01168011-I1Open ↗
10/03/2026B01168011-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B01168011-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01168011-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01168011-I1Open ↗